摘要
Aims Abandoned leads are often linked to complications during lead extraction, prompting pre-emptive extraction if leads become non-functional. We examined their influence on complications when extracted for device-related infection. Methods and results All patients undergoing lead extraction for device-related infection from 2006 to 2017 in our hospital were included. The primary endpoint was major complications. Out of 500 patients, 141 had abandoned leads, of whom 75% had only one abandoned lead. Median cumulative implant times were 24.2 (interquartile range 15.6-38.2) and 11.6 (5.6-17.4), respectively years with or without abandoned leads. All leads were extracted only with a femoral approach in 50.4% of patients. Mechanical rotational tools were introduced in 2014 and used in 22.2% of cases and replacing laser sheaths that were used in 5% of patients. Major complications occurred in 0.7% of patients with abandoned leads compared with 1.7% of patients with only active leads (P = 0.679). Failure to completely remove all leads was 14.9% and 6.4%, respectively with or without abandoned leads (P = 0.003), and clinical failure was 6.4% and 2.2% (P = 0.028), respectively. Procedural failure dropped to 9.2% and 5.7% (P = 0.37), respectively after the introduction of mechanical rotational tools. The only independent predictor of procedural and clinical failure in multivariate analysis was the cumulative implant duration. Conclusion Despite longer implant times, patients with abandoned leads did not have more major complications during lead extraction. Therefore, preventive extraction of non-functional leads to avoid complications at a later stage is not warranted.
引用
收藏
页码:1378 / 1384
页数:7
相关论文
共 50 条
  • [31] Cardiovascular implantable electronic device infection: A complication of medical progress
    Shrestha, Nabin K.
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 2011, 78 (08) : 500 - +
  • [32] Prevalence and prognosis of lead masses in patients with cardiac implantable electronic devices without infection
    Golzio, Pier Giorgio
    Errigo, Daniele
    Peyracchia, Mattia
    Gallo, Elisa
    Frea, Simone
    Castagno, Davide
    Budano, Carlo
    Giustetto, Carla
    Rinaldi, Mauro
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (06) : 372 - 378
  • [33] Safety of Magnetic Resonance Imaging in Patients With Non-Transvenous Epicardial and Abandoned Cardiac Implantable Electronic Device Leads
    Palmeri, Nicholas O.
    York, Linda R.
    Emily, Wacks
    Kramer, Daniel B.
    CIRCULATION, 2020, 142
  • [34] Impact of Abandoned Leads on Cardiovascular Implantable Electronic Device Infections A Propensity Matched Analysis of MEDIC (Multicenter Electrophysiologic Device Infection Cohort)
    Boyle, Thomas A.
    Uslan, Daniel Z.
    Prutkin, Jordan M.
    Greenspon, Arnold J.
    Baddour, Larry M.
    Danik, Stephan B.
    Tolosana, Jose M.
    Le, Katherine
    Miro, Jose M.
    Peacock, James E.
    Sohail, Muhammad R.
    Vikram, Holenarasipur R.
    Carrillo, Roger G.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (02) : 201 - 208
  • [35] Lead Extraction and Mortality Among Patients With Cardiac Implanted Electronic Device Infection
    Pokorney, Sean D.
    Zepel, Lindsay
    Greiner, Melissa A.
    Fowler, Vance G., Jr.
    Black-Maier, Eric
    Lewis, Robert K.
    Hegland, Donald D.
    Granger, Christopher B.
    Epstein, Laurence M.
    Carrillo, Roger G.
    Wilkoff, Bruce L.
    Hardy, Chantelle
    Piccini, Jonathan P.
    JAMA CARDIOLOGY, 2023, 8 (12) : 1165 - 1173
  • [36] Surgical Management of Cardiac Implantable Electronic Device Complications in Patients Unsuitable for Transvenous Lead Extraction
    Miyagi, Yasuo
    Oomori, Hiroya
    Maeda, Motohiro
    Murata, Tomohiro
    Ota, Keisuke
    Motoji, Yusuke
    Amitani, Ryosuke
    Ueda, Hitomi
    Morishima, Motoko
    Matsuyama, Takayoshi
    Kurita, Jiro
    Maruyama, Yuji
    Sasaki, Takashi
    Sakamoto, Shun-ichiro
    Ishii, Yosuke
    CIRCULATION JOURNAL, 2023, 87 (01) : 103 - 110
  • [37] Transvenous lead extraction at the time of cardiac implantable electronic device upgrade: Complexity, safety, and outcomes
    Barakat, Amr F.
    Wazni, Oussama M.
    Tarakji, Khaldoun
    Saliba, Walid I.
    Nimri, Nayef
    Rickard, John
    Brunner, Michael
    Bhargava, Mandeep
    Kanj, Mohamed
    Baranowski, Bryan
    Martin, David O.
    Cantillon, Daniel
    Callahan, Thomas
    Dresing, Thomas
    Niebauer, Mark
    Chung, Mina
    Lindsay, Bruce D.
    Wilkoff, Bruce
    Hussein, Ayman A.
    HEART RHYTHM, 2017, 14 (12) : 1807 - 1811
  • [38] Enterobacter Cloacae Cardiac Implantable Electronic Device Infection
    Fanucci, Victoria
    Chauhan, Dhaval
    Mascio, Christopher E.
    Arora, Sandeep
    Gupta, Shipra
    Weisse, Martin E.
    Kohli, Utkarsh
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2024, 43 (10) : e374 - e376
  • [39] Review of cardiac implantable electronic device related infection
    Saliba, Emile
    Massie, Emmanuelle
    Sia, Ying Tung
    RESEARCH REPORTS IN CLINICAL CARDIOLOGY, 2016, 7 : 137 - 146
  • [40] Implantable cardiac electronic device infection: a growing danger?
    Rishton, Louise
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2012, 10 (06) : 683 - 683