摘要
The Nintendo Wii balance board (WBB) has generated significant interest in its application as a postural control measurement device in both the clinical and (basic, clinical, and rehabilitation) research domains. Although the WBB has been proposed as an alternative to the "gold standard" laboratory-grade force plate, additional research is necessary before the WBB can be considered a valid and reliable center of pressure (CoP) measurement device. In this study, we used the WBB and a laboratory-grade AMTI force plate (AFP) to simultaneously measure the CoP displacement of a controlled dynamic load, which has not been done before. A one-dimensional inverted pendulum was displaced at several different displacement angles and load heights to simulate a variety of postural sway amplitudes and frequencies (<1 Hz). Twelve WBBs were tested to address the issue of inter-device variability. There was a significant effect of sway amplitude, frequency, and direction on the WBB's CoP measurement error, with an increase in error as both sway amplitude and frequency increased and a significantly greater error in the mediolateral (ML) (compared to the anteroposterior (AP)) sway direction. There was no difference in error across the 12 WBB's, supporting low inter-device variability. A linear calibration procedure was then implemented to correct the WBB's CoP signals and reduce measurement error. There was a significant effect of calibration on the WBB's CoP signal accuracy, with a significant reduction in CoP measurement error (quantified by root-mean-squared error) from 2-6 mm (before calibration) to 0.5-2 mm (after calibration). WBB-based CoP signal calibration also significantly reduced the percent error in derived (time-domain) CoP sway measures, from -10.5% (before calibration) to -0.05% (after calibration) (percent errors averaged across all sway measures and in both sway directions). In this study, we characterized the WBB's CoP measurement error under controlled, dynamic conditions and implemented a linear calibration procedure for WBB CoP signals that is recommended to reduce CoP measurement error and provide more reliable estimates of time-domain CoP measures. Despite our promising results, additional work is necessary to understand how our findings translate to the clinical and rehabilitation research domains. Once the WBB's CoP measurement error is fully characterized in human postural sway (which differs from our simulated postural sway in both amplitude and frequency content), it may be used to measure CoP displacement in situations where lower accuracy and precision is acceptable.
引用
收藏
页码:18244 / 18267
页数:24
相关论文
共 50 条
  • [21] Open Source Affordable Balance Testing based on a Nintendo Wii Balance Board
    Hyldgaard, David
    von Schweder, Frederik Jarosch
    Ali, Qasim
    Heldal, Ilona
    Knapstad, Mari Kalland
    Aasen, Torbjorn
    [J]. 2021 INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING (EHB 2021), 9TH EDITION, 2021,
  • [22] Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board
    June Quek
    Julia Treleaven
    Sandra G. Brauer
    Shaun O’Leary
    Ross A. Clark
    [J]. Journal of Foot and Ankle Research, 8
  • [23] Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board
    Quek, June
    Treleaven, Julia
    Brauer, Sandra G.
    O'Leary, Shaun
    Clark, Ross A.
    [J]. JOURNAL OF FOOT AND ANKLE RESEARCH, 2015, 8
  • [24] Suitability of Nintendo Wii Balance Board for rehabilitation of standing after stroke
    Harvey, Nathan
    Ada, Louise
    [J]. PHYSICAL THERAPY REVIEWS, 2012, 17 (05) : 311 - 321
  • [25] Validity of the Nintendo Wii® balance board for the assessment of standing balance in Parkinson's disease
    Holmes, Jeffrey D.
    Jenkins, Mary E.
    Johnson, Andrew M.
    Hunt, Michael A.
    Clark, Ross A.
    [J]. CLINICAL REHABILITATION, 2013, 27 (04) : 361 - 366
  • [26] Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation
    Park, Dae-Sung
    Lee, GyuChang
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [27] Novel Use of Nintendo Wii Balance Board for Automatic Evaluation on Motion Quality
    Liang, Zilu
    Nishimura, Takuichi
    Iino, Nami
    Yoshida, Yasuyuki
    Nishimura, Satoshi
    [J]. 2017 IEEE 6TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE), 2017,
  • [28] Measurements of Weight Bearing Asymmetry Using the Nintendo Wii Fit Balance Board Are Not Reliable for Older Adults and Individuals With Stroke
    Liuzzo, Derek M.
    Peters, Denise M.
    Middleton, Addie
    Lanier, Wes
    Chain, Rebecca
    Barksdale, Brittany
    Fritz, Stacy L.
    [J]. JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2017, 40 (01) : 37 - 41
  • [29] Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation
    Dae-Sung Park
    GyuChang Lee
    [J]. Journal of NeuroEngineering and Rehabilitation, 11
  • [30] Use of Nintendo Wii Balance Board for posturographic analysis of Multiple Sclerosis patients with minimal balance impairment
    Giacomo Severini
    Sofia Straudi
    Claudia Pavarelli
    Marco Da Roit
    Carlotta Martinuzzi
    Laura Di Marco Pizzongolo
    Nino Basaglia
    [J]. Journal of NeuroEngineering and Rehabilitation, 14