Bismuth-Coated Reticulated Vitreous Carbon and Bismuth-Coated Glassy Carbon Electrodes for On-Line Coupling of ASV with ICP-MS

被引:3
|
作者
Liu, Lin [1 ,2 ]
Do, Huy N. L. [2 ]
Wang, Jianxiu [1 ]
Zhou, Feimeng [1 ,2 ]
机构
[1] Cent S Univ, Coll Chem & Chem Engn, Changsha 410083, Hunan, Peoples R China
[2] Calif State Univ Los Angeles, Dept Chem & Biochem, Los Angeles, CA 90032 USA
基金
中国国家自然科学基金;
关键词
ASV-ICP-MS; Bismuth; Reticulated vitreous carbon; Glassy carbon; Sample preconcentration; Matrix effect elimination; Thin films; ANODIC-STRIPPING VOLTAMMETRY; ATOMIC EMISSION-SPECTROMETRY; PLASMA-MASS SPECTROMETRY; MERCURY FILM ELECTRODES; FLOW CELL; PRETREATMENT; CADMIUM; URANIUM; COBALT; COPPER;
D O I
10.1002/elan.200900485
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anodic stripping voltammetry (ASV) has been combined on-line with inductively coupled plasma-mass spectrometry (ICP-MS) using both Bi-coated reticulated vitreous carbon (RVC) and Bi-coated glassy carbon (GC) disk electrodes. Because the same flow cell is used for the RVC and GC disk electrodes, the analytical performances between these two types of Bi-coated electrodes can be accurately compared for their utilizations in the ASV-ICP-MS technique. Comparison of the performances includes signal enhancement, reproducibility, dynamic range, and hydrodynamic stability of the Bi coating. The results indicate that the signal enhancement produced by the Bi-coated RVC electrode (in the flow-through configuration) is greater, while the hydrodynamic stability of the Bi-coated GC disk electrode is better. Both types of electrodes were found to be highly effective in eliminating the matrix effects that are detrimental to ICP-MS analysis. For the purpose of metal preconcentration. Bi has similar properties to Hg (e.g., high hydrogen overpotential and ability to accumulate a range of analytes). However, the Bi film is more robust than the Hg film in a flow system and, unlike Hg2+, Bi3+ in the solution does not cause the memory effect (i.e., it does not adhere onto glass nebulizer and spray chamber of ICP over a long period of time). The nontoxicity of bismuth also makes it an environmentally friendly alternative to mercury for coupling ASV on-line with ICP-based techniques.
引用
收藏
页码:1476 / 1482
页数:7
相关论文
共 31 条
  • [21] Parallel on-line detection of a methylbismuth species by hyphenated GC/EI-MS/ICP-MS technique as evidence for bismuth methylation by human hepatic cells
    Hollmann, Markus
    Boertz, Jens
    Dopp, Elke
    Hippler, Joerg
    Hirner, Alfred Vitalis
    [J]. METALLOMICS, 2010, 2 (01) : 52 - 56
  • [22] A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS
    Chen, Zhenna
    Chen, Beibei
    He, Man
    Wang, Han
    Hu, Bin
    [J]. MICROCHIMICA ACTA, 2019, 186 (02)
  • [23] A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS
    Zhenna Chen
    Beibei Chen
    Man He
    Han Wang
    Bin Hu
    [J]. Microchimica Acta, 2019, 186
  • [24] Plasma-catalyst interactions in the treatment of volatile organic compounds and NOx with pulsed corona discharge and reticulated vitreous carbon Pt/Rh-coated electrodes
    Kirkpatrick, MJ
    Finney, WC
    Locke, BR
    [J]. CATALYSIS TODAY, 2004, 89 (1-2) : 117 - 126
  • [25] Determination of Trace Rare Earth Elements by ICP-MS after On-line Column Preconcentration and Separation with Single-Wall Carbon Nanotubes
    Chen, Shizhong
    Liu, Cheng
    Lu, Dengbo
    Zhu, Li
    [J]. ATOMIC SPECTROSCOPY, 2009, 30 (01) : 20 - 25
  • [26] Plasma-catalyst interactions in the treatment of volatile organic compounds and nox with pulsed corona discharge and reticulated vitreous carbon Pt/Rh-coated electrodes.
    Kirkpatrick, MJ
    Finney, WC
    Clarks, RJ
    Locke, BR
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U53 - U53
  • [27] Study on speciation of aluminum in human serum using zwitterionic bile acid derivative dynamically coated C18 column HPLC separation with UV and on-line ICP-MS detection
    Chen, Beibei
    Zeng, Yan
    Hu, Bin
    [J]. TALANTA, 2010, 81 (1-2) : 180 - 186
  • [28] Simultaneous Determination of Rare Earth Elements by ICP OES After On-Line Enrichment Using Multi-Walled Carbon Nanotubes Coated Cellulose Acetate Membrane
    Zolfonoun, Ehsan
    Yousefi, Seyed Reza
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (12) : 2348 - 2353
  • [29] Thermo-responsive polymer coated fiber-in-tube capillary microextraction and its application to on-line determination of Co, Ni and Cd by inductively coupled plasma mass spectrometry (ICP-MS)
    Zheng, Fei
    Hu, Bin
    [J]. TALANTA, 2011, 85 (02) : 1166 - 1173
  • [30] Carbon-coated Fe3O4 nanoparticles with surface amido groups for magnetic solid phase extraction of Cr(III), Co(II), Cd(II), Zn(II) and Pb(II) prior to their quantitation by ICP-MS
    Mohamed A. Habila
    Zeid A. ALOthman
    Ahmed Mohamed El-Toni
    Saad A. Al-Tamrah
    Mustafa Soylak
    Joselito Puzon Labis
    [J]. Microchimica Acta, 2017, 184 : 2645 - 2651