Real-time visualization of renal microperfusion using laser speckle contrast imaging

被引:14
|
作者
Heeman, Wido [1 ,2 ,3 ]
Maassen, Hanno [2 ,4 ]
Calon, Joost [5 ]
van Goor, Harry [4 ]
Leuvenink, Henri [2 ]
van Dam, Gooitzen M. [2 ]
Boerma, E. Christiaan [6 ]
机构
[1] Univ Groningen, Fac Campus Fryslan, Leeuwarden, Netherlands
[2] Univ Med Ctr Groningen, Dept Surg, Groningen, Netherlands
[3] LIMIS Dev BV, Leeuwarden, Netherlands
[4] Univ Med Ctr Groningen, Dept Pathol & Med Biol, Groningen, Netherlands
[5] ZiuZ Visual Intelligence, Gorredijk, Netherlands
[6] Med Ctr Leeuwarden, Dept Intens Care, Leeuwarden, Netherlands
关键词
laser speckle contrast imaging; transplantation; kidney; sidestream dark-field imaging; renal microperfusion; HUMAN KIDNEY; PERFUSION; MICROCIRCULATION; INJURY;
D O I
10.1117/1.JBO.26.5.056004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Intraoperative parameters of renal cortical microperfusion (RCM) have been associated with postoperative ischemia/reperfusion injury. Laser speckle contrast imaging (LSCI) could provide valuable information in this regard with the advantage over the current standard of care of being a non-contact and full-field imaging technique. Aim: Our study aims to validate the use of LSCI for the visualization of RCM on ex vivo perfused human-sized porcine kidneys in various models of hemodynamic changes. Approach: A comparison was made between three renal perfusion measures: LSCI, the total arterial renal blood flow (RBF), and sidestream dark-field (SDF) imaging in different settings of ischemia/reperfusion. Results: LSCI showed a good correlation with RBF for the reperfusion experiment (0.94 +/- 0.02; p < 0.0001) and short- and long-lasting local ischemia (0.90 +/- 0.03; p < 0.0001 and 0.81 +/- 0.08; p < 0.0001, respectively). The correlation decreased for low flow situations due to RBF redistribution. The correlation between LSCI and SDF (0.81 +/- 0.10; p < 0.0001) showed superiority over RBF (0.54 +/- 0.22; p < 0.0001). Conclusions: LSCI is capable of imaging RCM with high spatial and temporal resolutions. It can instantaneously detect local perfusion deficits, which is not possible with the current standard of care. Further development of LSCI in transplant surgery could help with clinical decision making. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Multimodal real-time imaging with laser speckle contrast and fluorescent contrast
    Park, Hyun-Seo
    Shim, Min-Jae
    Kim, Yikeun
    Ko, Taek-Yong
    Choi, Jin-Hyuk
    Ahn, Yeh-Chan
    [J]. PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 45
  • [2] Intraoperative real-time and continuous cerebral blood flow visualization with laser speckle contrast imaging
    Miller, David R.
    Ashour, Ramsey
    Sullender, Colin T.
    Dunn, Andrew K.
    [J]. CLINICAL AND TRANSLATIONAL NEUROPHOTONICS 2022, 2022, 11945
  • [3] ACTIVSIGHT™: REAL-TIME, DYE-FREE VISUALIZATION OF BOWEL PERFUSION USING LASER SPECKLE CONTRAST IMAGING.
    Nwaiwu, C. A.
    Liu, Y. Z.
    Mehrotra, S.
    Wilson, E. B.
    Schwaitzberg, S. D.
    Park, A.
    Kalady, M. F.
    Kim, P. C.
    [J]. DISEASES OF THE COLON & RECTUM, 2022, 65 (05) : 248 - 248
  • [4] Real-time monitoring of biomechanical activity in aphids by laser speckle contrast imaging
    Yordanov, Stoyan
    Drucker, Martin
    Butt, Hans-Jurgen
    Koynov, Kaloian
    [J]. OPTICS EXPRESS, 2021, 29 (18) : 28461 - 28480
  • [5] Real-time quantification of bowel perfusion using Laparoscopic Laser Speckle Contrast Imaging (LSCI) in a porcine model
    Saloni Mehrotra
    Yao Z. Liu
    Chibueze A. Nwaiwu
    Vasiliy E. Buharin
    Roman Stolyarov
    Steven D. Schwaitzberg
    Matthew F. Kalady
    Peter C. W. Kim
    [J]. BMC Surgery, 23
  • [6] Cortical Hemodynamic Responses Under Focused Ultrasound Stimulation Using Real-Time Laser Speckle Contrast Imaging
    Yuan, Yi
    Zhao, Yanchao
    Jia, Hongshuai
    Liu, Mengyang
    Hui, Shuo
    Li, Yingwei
    Li, Xiaoli
    [J]. FRONTIERS IN NEUROSCIENCE, 2018, 12
  • [7] Real-time quantification of bowel perfusion using Laparoscopic Laser Speckle Contrast Imaging (LSCI) in a porcine model
    Mehrotra, Saloni
    Liu, Yao Z.
    Nwaiwu, Chibueze A.
    Buharin, Vasiliy E.
    Stolyarov, Roman
    Schwaitzberg, Steven D.
    Kalady, Matthew F.
    Kim, Peter C. W.
    [J]. BMC SURGERY, 2023, 23 (01)
  • [8] Robust Estimation of Vessel Misfocus and Real-time Misfocus Correction in Laser Speckle Contrast Imaging
    Ringuette, Dene
    Sigal, Iliya
    Levi, Ofer
    [J]. BIOMEDICAL APPLICATIONS OF LIGHT SCATTERING IX, 2015, 9333
  • [9] Dual-display laparoscopic laser speckle contrast imaging for real-time surgical assistance
    Zheng, Corey
    Lau, Lung Wai
    Cha, Jaepyeong
    [J]. BIOMEDICAL OPTICS EXPRESS, 2018, 9 (12): : 5962 - 5981
  • [10] Real-time video-rate perfusion imaging using multi-exposure laser speckle contrast imaging and machine learning
    Hultman, Martin
    Larsson, Marcus
    Stromberg, Tomas
    Fredriksson, Ingemar
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (11)