Image correction in magneto-optical microscopy

被引:11
|
作者
Paturi, P [1 ]
Larsen, BH
Jacobsen, BA
Andersen, NH
机构
[1] Univ Turku, Dept Phys, Wihuri Phys Lab, FIN-20014 Turku, Finland
[2] Riso Natl Lab, Mat Res Dept, DK-4000 Roskilde, Denmark
[3] NKT Res AS, DK-2605 Brondby, Denmark
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2003年 / 74卷 / 06期
关键词
D O I
10.1063/1.1571952
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An image-processing procedure that assures correct determination of the magnetic field distribution of magneto-optical images is presented. The method remedies image faults resulting from sources that are proportional to the incident light intensity, such as different types of defects in the indicator film and unevenness of light, as well as additive signals from detector bias, external light sources, etc. When properly corrected a better measurement of the local magnetic field can be made, even in the case of heavily damaged films. For superconductors the magnetic field distributions may be used for accurate determination of the current distributions without the spurious current loops associated with defects in the films. (C) 2003 American Institute of Physics.
引用
收藏
页码:2999 / 3001
页数:3
相关论文
共 50 条
  • [31] Magneto-optical heterostructures with second resonance of transverse magneto-optical Kerr effect
    Rezaeian, Amene
    Farzad, Mahmood Hosseini
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01)
  • [32] Magneto-optical heterostructures with second resonance of transverse magneto-optical Kerr effect
    Amene Rezaeian
    Mahmood Hosseini Farzad
    [J]. Scientific Reports, 14
  • [33] Near-field magneto-optical microscopy in collection and illumination mode
    Matthes, F
    Bruckl, H
    Reiss, G
    [J]. ULTRAMICROSCOPY, 1998, 71 (1-4) : 243 - 248
  • [34] Optimization of electromagnet for high-field polar magneto-optical microscopy
    Lukas, D.
    Postava, K.
    Zivotsky, O.
    Pistora, J.
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2010, 322 (9-12) : 1471 - 1474
  • [35] Domain observation in Magneto-Optical recording media using Lorentz microscopy
    Yatsuya, S
    [J]. ELECTRON MICROSCOPY 1998, VOL 2: MATERIALS SCIENCE 1, 1998, : 561 - 562
  • [36] Magneto-optical indicator film (MOIF) microscopy of granular and layer structures
    Nikitenko, VI
    Gornakov, VS
    Dedukh, LM
    Khapikov, AF
    Bennett, LH
    McMichael, RD
    Swartzendruber, LJ
    Shapiro, AJ
    Donahue, MJ
    Matveev, VN
    Levashov, VI
    [J]. JOURNAL OF APPLIED PHYSICS, 1996, 79 (08) : 6073 - 6073
  • [37] Study of functioning of the magneto-optical method as part of magnetic force microscopy
    Vysokikh Y.E.
    Shelaev A.V.
    Shevyakov V.I.
    Prokopov A.R.
    Belov A.N.
    Krasnoborod’ko S.Y.
    [J]. Nanotechnologies in Russia, 2016, 11 (11-12): : 815 - 819
  • [38] Theoretical aspects of near-field magneto-optics and scanning magneto-optical microscopy
    Kosobukin, VA
    [J]. NEAR-FIELD OPTICS: PHYSICS, DEVICES, AND INFORMATION PROCESSING, 1999, 3791 : 93 - 101
  • [39] OPTICAL AND MAGNETO-OPTICAL PROPERTIES OF NDS
    BRANDLE, H
    SCHOENES, J
    HULLIGER, F
    [J]. HELVETICA PHYSICA ACTA, 1989, 62 (2-3): : 199 - 202
  • [40] Optical and magneto-optical properties of gadolinium
    Saini, Sapan Mohan
    Singh, Nirpendra
    Nautiyal, Tashi
    Auluck, Sushil
    [J]. JOURNAL OF APPLIED PHYSICS, 2007, 101 (03)