Effect of Image Degradation on nm-scale MEMS FFT optical displacement measurements

被引:0
|
作者
King, Hunter [1 ]
Warnat, Stephan [1 ]
Hubbard, Ted [1 ]
机构
[1] Dalhousie Univ, Dept Mech Engn, Halifax, NS B3J 2X4, Canada
关键词
ACTUATORS;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This paper examines the optical measurement of nm-scale MEMS in-plane motion using microphotographs, and the effect of degraded images on these results. Two common forms of image degradation are: blurring caused by the dynamic (AC) motion of the actuator and focus effects due to changes in focal plane or media changes. This paper address whether consistent nm-scale results can still be obtained when the image is thus changed. The motion of MEMS thermal actuators was measured by taking a series of undegraded microphotographs at varying DC voltages that produce displacements of similar to 2.5 microns. A FFT based algorithm was used to analyze the phase of periodic structures in the image and measure displacements with precision on the order of 20-100 nm. Pristine undegraded measurements were compared with both artificially blurred images as well as manually defocused images. It was found that the FFT method was robust to large amounts of blurring and defocusing.
引用
收藏
页码:1387 / 1392
页数:6
相关论文
共 37 条
  • [31] Effect of radiation-induced mean wavelength shift in optical fibers on the scale factor of an interferometric fiber optic gyroscope at a wavelength of 1300 nm
    金靖
    王学勤
    林松
    宋凝芳
    Chinese Physics B, 2012, 21 (09) : 366 - 372
  • [32] Effects of Spectral-Domain Optical Coherence Tomography Image Quality Degradation on Retinal Nerve Fiber Layer and Macular Thickness Measurements in Normal Individuals.
    Chaon, Benjamin
    Eldweik, Luai
    Lee, Michael S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [33] Bookshelf Kinematics and the Effect of Dilatation on Fault Zone Inelastic Deformation: Examples From Optical Image Correlation Measurements of the 2019 Ridgecrest Earthquake Sequence
    Milliner, Christopher
    Donnellan, Andrea
    Aati, Saif
    Avouac, Jean-Philippe
    Zinke, Robert
    Dolan, James F.
    Wang, Kang
    Burgmann, Roland
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2021, 126 (03)
  • [34] Ganglion cell thickness measurements obtained using Optical coherence tomography (OCT): Effect of retinal location, foveal cutout diameter and image segmentation
    Davey, Pinakin Gunvant
    Dong, Ying
    Yang, Qi
    Huang, Wei Chieh
    Leung, Danny
    Ng, Edmund
    Reisman, Charles A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [35] The effect of manually refining automated image segmentations on retinal nerve fiber layer thickness measurements from optical coherence tomography (OCT) scans
    Menda, Shivali
    Fortune, Brad
    Mansberger, Steven L.
    Gardiner, Stuart Keith
    Demirel, Shaban
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [36] Visualization and measurements of two-phase flows in metallic ducts using neutrons as microscopic probes (4th report. Effect of image gray scale and pixel number on image quantification)
    Hibiki, T.
    Mishima, K.
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1996, 62 (597): : 1781 - 1787
  • [37] An adaptive atmospheric correction algorithm for the effective adjacency effect correction of submeter-scale spatial resolution optical satellite images: Application to a WorldView-3 panchromatic image
    Wang, Tao
    Du, Lili
    Yi, Weining
    Hong, Jin
    Zhang, Liming
    Zheng, Jianyu
    Li, Chao
    Ma, Xiaoshan
    Zhang, Dongying
    Fang, Wei
    Huang, Honglian
    Wang, Anjing
    Song, Bo
    Zhou, Nan
    Ti, Rufang
    Li, Kaitao
    Cui, Wenyu
    REMOTE SENSING OF ENVIRONMENT, 2021, 259