Prediction of the central venous pressure in trauma patients on the basis of non-invasive parameters using artificial neural network

被引:2
|
作者
Moinadini, Shiva [1 ]
Tajoddini, Shahrad [2 ]
Hedayat, Amir Ahmad [3 ]
机构
[1] Rafsanjan Univ Med Sci, Aliebn Hosp, Dept Emergency Med, Mofateh Blvd, Rafsanjan 7717933777, Iran
[2] Kerman Univ Med Sci, Dept Emergency Med, Kerman, Iran
[3] Islamic Azad Univ, Dept Civil Engn, Kerman Branch, Kerman, Iran
关键词
Central venous pressure; non-invasive parameters; caval index; base excess; lactate clearance; artificial neural network; INFERIOR VENA-CAVA; EARLY LACTATE CLEARANCE; GOAL-DIRECTED THERAPY; SEVERE SEPSIS; SHOCK INDEX; RESUSCITATION; MANAGEMENT; DIAGNOSIS; SURVIVAL; PROTOCOL;
D O I
10.1177/1024907919855881
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Generally, in traumatic patients, uncontrolled bleeding leads to shock and ultimately death. So, any early detection of shock can reduce the likelihood of a patient's death. At present, the precise method for estimating the body's need for fluids is to measure central venous pressure (CVP). However, this method is invasive and time consuming. Objective: This study aimed to predict the central venous pressure value and range of trauma patients through non-invasive parameters such as caval index, lactate clearance, base excess and shock index. Methods: A prospective observational study was performed in 100 trauma patients. Written informed consent was obtained from patient(s) or relatives for their anonymized information to be published in any article. Results: It indicated that parameters such as caval index (at a proposed cutoff point of 35%), lactate clearance (at a cutoff point of 6%) and base excess (at a proposed cutoff point of 6 mmol/L) are approximately of the same level of accuracy for estimating the central venous pressure range, while parameter shock index (at a cutoff point of 1.25) is of the least level of accuracy to predict the central venous pressure range. Results also showed that among all proposed predictive models for estimating the central venous pressure value, which were on the basis of either non-linear regression or artificial neural network, the most accurate model was the one on the basis of the artificial neural network. Among parameters lactate clearance, base excess and shock index used to form the artificial neural network-based model, parameters base excess and lactate clearance were of the highest and lowest level of importance, respectively. Conclusion: Among all proposed models and non-invasive parameters to predict the central venous pressure range, CVPLC model (at a cutoff point of 9), which is a non-linear regression model and is in terms of parameter lactate clearance, was the most accurate model.
引用
收藏
页码:152 / 164
页数:13
相关论文
共 50 条
  • [21] SOME OBSERVATIONS ON PERIPHERAL VENOUS PRESSURE USING A NON-INVASIVE TECHNIQUE
    GAYLIS, H
    [J]. SOUTH AFRICAN JOURNAL OF SURGERY, 1974, 12 (02) : 67 - 68
  • [22] Prediction of compressibility parameters of the soils using artificial neural network
    Kurnaz, T. Fikret
    Dagdeviren, Ugur
    Yildiz, Murat
    Ozkan, Ozhan
    [J]. SPRINGERPLUS, 2016, 5
  • [23] An artificial neural network improves the non-invasive diagnosis of significant fibrosis in HIV/HCV coinfected patients
    Resino, Salvador
    Antonio Seoane, Jose
    Maria Bellon, Jose
    Dorado, Julian
    Martin-Sanchez, Fernando
    Alvarez, Emilio
    Cosin, Jaime
    Carlos Lopez, Juan
    Lopez, Guilllermo
    Miralles, Pilar
    Berenguer, Juan
    [J]. JOURNAL OF INFECTION, 2011, 62 (01) : 77 - 86
  • [24] Improvement of Blood Pressure Prediction Using Artificial Neural Network
    Katayama, Kyoko
    Koyama, Shouhei
    Ishizawa, Hiroaki
    Fujimoto, Keisaku
    [J]. 2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 223 - 227
  • [25] Non-invasive fermentation analysis using an artificial neural network algorithm for processing near infrared spectra
    Li, Y
    Brown, CW
    Sun, FM
    McCrady, JW
    Traxler, RW
    Lo, SC
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 1999, 7 (02) : 101 - 108
  • [26] A Novel Non-Invasive Device for the Assessment of Central Venous Pressure in Hospital, Office and Home
    Marcelli, Emanuela
    Cercenelli, Laura
    Bortolani, Barbara
    Marini, Saverio
    Arfilli, Luca
    Capucci, Alessandro
    Plicchi, Gianni
    [J]. MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2021, 14 : 141 - 154
  • [27] ARTIFICIAL NEURAL NETWORK APPLICATION ON NON-INVASIVE UROFLOWMETRY PARAMETERS AND FLOW SHAPE FOR DISCRIMINATING DU FROM BOO IN MALES
    Li, R.
    Gammie, A.
    Zhu, Q.
    Nibouche, M.
    Chen, C.
    [J]. NEUROUROLOGY AND URODYNAMICS, 2019, 38 : S241 - S242
  • [28] Non-Invasive Air-Writing Using Deep Neural Network
    Perotto, Matteo
    Gemma, Luca
    Brunelli, Davide
    [J]. 2021 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 & IOT (IEEE METROIND4.0 & IOT), 2021, : 88 - 93
  • [29] Prediction of Venous Thromboembolism in Patients with Cancer Using Neural Network
    De Laat-Kremers, Romy
    Tagawa, Scott
    Young, Madeline
    Garcia, Christine
    Shah, Manish
    Kasi, Pashtoon Murtaza
    Rand, Jacob H.
    De Laat, Bas
    DeSancho, Maria T.
    [J]. BLOOD, 2023, 142
  • [30] An artificial neural network as a model for prediction of survival in trauma patients: Validation for a regional trauma area
    DiRusso, SM
    Sullivan, T
    Holly, C
    Cuff, SN
    Savino, J
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 49 (02): : 212 - 220