Comparison of Two Three-Dimensional Printed Models of Complex Intracranial Aneurysms for Surgical Simulation

被引:24
|
作者
Wang, Liang [1 ,2 ,3 ,4 ,5 ]
Ye, Xun [1 ,2 ,3 ]
Hao, Qiang [1 ,2 ,3 ]
Chen, Yu [1 ,2 ,3 ]
Chen, Xiaolin [1 ,2 ,3 ]
Wang, Hao [1 ,2 ,3 ]
Wang, Rong [1 ,2 ,3 ]
Zhao, Yuanli [1 ,2 ,3 ]
Zhao, Jizong [1 ,2 ,3 ]
机构
[1] Capital Med Univ, Dept Neurosurg, Beijing Tian Tan Hosp, Beijing, Peoples R China
[2] Beijing Translat Engn Ctr 3D Printer Clin Neurosc, Beijing, Peoples R China
[3] China Natl Clin Res Ctr Neurol Dis, Beijing, Peoples R China
[4] Tianjin Fifth Ctr Hosp, Dept Neurosurg, Tianjin, Peoples R China
[5] Peking Univ, Int Hosp, Dept Neurosurg, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Aneurysm; Clipping; Surgery simulator; Surgical training; Three-dimensional model; Three-dimensional printing; TRIAL ISAT; SURGERY; OCCLUSION;
D O I
10.1016/j.wneu.2017.04.098
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To compare two 3-dimensional (3D) printed models of intracranial aneurysms for simulation and training for complex aneurysm surgery. METHODS: The study included 6 complex or large aneurysm cases. We printed two 3D models of complex aneurysms based on computed tomography angiography data using a 3D printer: a whole model, which was all-in-one printed hollow aneurysm method with colorful and multiple materials and included the hollow aneurysm, adjacent arteries, skull base, and nerves, and a regional model that included the hollow aneurysm and adjacent arteries. The 3D models were used for surgical planning and for practice in craniotomy and clipping. Neurosurgeons rated the models via questionnaires. RESULTS: Both 3D aneurysm models were accurate: the diameter, width, and neck of the aneurysms in the models were not significantly different from the computed tomography angiography data (P > 0.05). Furthermore, the models were useful for selecting clips before surgery. The whole 3D model improved understanding of the surgical view more than the regional model did (P < 0.05); however, the clip application felt more realistic in the regional model (P < 0.05). The process time for making the whole model is shorter (P < 0.05) but more expensive (P < 0.05) compared with the regional model. CONCLUSIONS: The whole and regional 3D printed aneurysm models were accurate. The whole model was more useful for planning the trajectory of approach to the aneurysm when it was located in close proximity to bone and nerves, whereas the regional 3D aneurysm model was appropriate for aneurysms not involving bone and nerves. This will help neurosurgeon choose the proper 3D model for the complex aneurysm surgery according to the comparison.
引用
收藏
页码:671 / 679
页数:9
相关论文
共 50 条
  • [41] Three-dimensional CT angiography in the detection and characterization of intracranial berry aneurysms
    Hope, JKA
    Wilson, JL
    Thomson, FJ
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (03) : 439 - 445
  • [42] Three-Dimensional Morphological Change of Intracranial Aneurysms Before and Around Rupture
    Kamphuis, Maarten J.
    Timmins, Kimberley M.
    Kuijf, Hugo J.
    de Graaf, Eva K. L.
    Rinkel, Gabriel J. E.
    Vergouwen, Mervyn D. I.
    van der Schaaf, Irene C.
    [J]. NEUROSURGERY, 2024, 94 (06) : 1211 - 1217
  • [43] Computer-Assisted Three-Dimensional Morphology Evaluation of Intracranial Aneurysms
    Rajabzadeh-Oghaz, Hamidreza
    Varble, Nicole
    Shallwani, Hussain
    Tutino, Vincent M.
    Mowla, Ashkan
    Shakir, Hakeem J.
    Vakharia, Kunal
    Atwal, Gursant S.
    Siddiqui, Adnan H.
    Davies, Jason M.
    Meng, Hui
    [J]. WORLD NEUROSURGERY, 2018, 119 : E541 - E550
  • [44] Three-dimensional electron beam CT angiography in the diagnosis of intracranial aneurysms
    Chen, S
    Shen, TZ
    Chen, XR
    [J]. CHINESE MEDICAL JOURNAL, 1999, 112 (08) : 739 - 742
  • [45] Three-Dimensional Biomodeling in Complex Mandibular Reconstruction and Surgical Simulation: Prospective Trial
    Dziegielewski, Peter T.
    Zhu, Jay
    King, Ben
    Grosvenor, Andrew
    Dobrovolsky, Walter
    Singh, Prabhjyot
    Ansari, Kal
    AL-Qahtani, Khalid H.
    Harris, Jeffrey R.
    Seikaly, Hadi
    [J]. JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2011, 40 : S70 - S81
  • [46] Osteotomy training for dental students using three-dimensional simulation software and maxillofacial three-dimensional-printed models
    Yoshida, Shuji
    Watanabe, Akira
    Sugahara, Keisuke
    Odaka, Kento
    Katakura, Akira
    Takano, Masayuki
    [J]. JOURNAL OF DENTAL EDUCATION, 2022, 86 (05) : 526 - 534
  • [47] Three-dimensional printed anatomical models in scaphoid surgery
    ten Berg, Paul W. L.
    Dobbe, Johannes G. G.
    Streekstra, Geert J.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (01) : 101 - 102
  • [48] Three-dimensional printed models in congenital heart disease
    Cantinotti, Massimiliano
    Valverde, Israel
    Kutty, Shelby
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (01): : 137 - 144
  • [49] Three-dimensional printed models in congenital heart disease
    Massimiliano Cantinotti
    Israel Valverde
    Shelby Kutty
    [J]. The International Journal of Cardiovascular Imaging, 2017, 33 : 137 - 144
  • [50] Simulation of Vertical Dynamic Vehicle-Track Interaction - Comparison of Two- and Three-Dimensional Models
    Aggestam, Emil
    Nielsen, Jens C. O.
    Sved, Niklas
    [J]. ADVANCES IN DYNAMICS OF VEHICLES ON ROADS AND TRACKS, IAVSD 2019, 2020, : 415 - 422