Measurement of Temperature for Diagnosing, and Treating the Osteomyelitis of Rat using an InGaSb Based Infrared Sensor with ICT Infrastructure

被引:1
|
作者
Murugeswari, S. [1 ]
Murugan, Kalpana [1 ]
机构
[1] Kalasalingam Acad Res & Educ, Dept Elect & Commun Engn, Krishnankoil, India
关键词
Osteomyelitis; Non-Invasive Temperature sensor; Rat; Bone; C10H16N4O3; C66H75Cl2N9O24;
D O I
10.1109/ICMNWC52512.2021.9687829
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
Osteomyelitis is a type of bone contamination that affects people. The most common symptoms are fever, soreness, weakness, and bone redness. The bioactive peptide homocarnosine (C10H16N4O3) is abundant in the cerebrum and skeletal muscles. This paper describes a novel method for detecting temperature due to osteomyelitis using an InGaSb-based Infrared temperature sensor, which was first tested on a rat. The temperature was detected and the synergistic effect of vancomycin (C66H75Cl2N9O24) and C10H16N4O3 against osteomyelitis in the treatment of bacterial infections was studied using 5 rat models. In summary, this work found that combining C10H16N4O3 and C66H75Cl2N9O24 treatment was more effective than C66H75Cl2N9O24 monotherapy in preventing bacterial growth and bone contamination. Rectal probe temperature readings have become common in recent years, and they have proven to be accurate and useful in this regard. Because of the drawbacks of invasive methods, noninvasive continuous monitoring technology has made significant advances in every aspect. Furthermore, non-invasive techniques are non-harmful, include rapid measurements, and do not disturb the subject of measurement. The temperature difference is being 0.2 degrees C on average between an InGaSb based Infrared temperature measurements and rectal measurements (Clinical values) and an accuracy of about 95% is achieved. This data is communicated via Wi-Fi (ESP8266) medium to the remote centre automatically.
引用
收藏
页数:5
相关论文
共 47 条
  • [41] Bragg-Grating-Based Photonic Strain and Temperature Sensor Foils Realized Using Imprinting and Operating at Very Near Infrared Wavelengths
    Missinne, Jeroen
    Beneitez, Nuria Teigell
    Mattelin, Marie-Aline
    Lamberti, Alfredo
    Luyckx, Geert
    Van Paepegem, Wim
    Van Steenberge, Geert
    [J]. SENSORS, 2018, 18 (08)
  • [42] Design of a Temperature Control system Using Incremental PID algorithm for a Special Homemade Shortwave Infrared Spatial Remote Sensor Based on FPGA
    Xu, Zhipeng
    Wei, Jun
    Li, Jianwei
    Zhou, Qianting
    [J]. ADVANCED SENSOR SYSTEMS AND APPLICATIONS IV, 2010, 7853
  • [43] In situ measurement of cross-section temperature field of pulverized coal boiler based on solving radiative transfer equation using a single image sensor
    Li, Tianjiao
    Hu, Zhichao
    Yan, Weijie
    Lou, Chun
    Liu, Dong
    Sun, Li
    Zhou, Huaichun
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2024, 40 (1-4)
  • [44] On-line temperature measurement using single-ended distributed cascading fiber Bragg gratings-based Brillouin optical fiber sensor
    Xu, Jin
    Wang, Rongping
    Cabani, Adnane
    Xu, Ping
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (03)
  • [45] Measurement of arterial, venous, and interstitial pO2 during acute hypoxia in rat brain using a time-resolved luminescence-based oxygen sensor
    Dunn, JF
    Nwaigwe, CI
    Roche, M
    [J]. OXYGEN TRANSPORT TO TISSUE XXI, 1999, 471 : 43 - 48
  • [46] Platinum RTD sensor based multi-channel high-precision temperature measurement system for temperature range -100 degrees C to +100 degrees C using single quartic function
    Sarkar, Shantanu
    [J]. COGENT ENGINEERING, 2018, 5 (01): : 1 - 15
  • [47] Automatic Crop Canopy Temperature Measurement Using a Low-Cost Image-Based Thermal Sensor: Application in a Pomegranate Orchard under a Permanent Shade Net House
    Gimenez-Gallego, Jaime
    Gonzalez-Teruel, Juan D. D.
    Blaya-Ros, Pedro J. J.
    Toledo-Moreo, Ana B. B.
    Domingo-Miguel, Rafael
    Torres-Sanchez, Roque
    [J]. SENSORS, 2023, 23 (06)