Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements:: A phase I trial

被引:33
|
作者
Boss, Andreas
Martirosian, Petros
Gehrmann, Michael
Artunc, Ferruh
Risler, Teut
Oesingmann, Niels
Claussen, Claus D.
Schick, Fritz
Kueper, Klaus
Schlemmer, Heinz-Peter
机构
[1] Univ Tubingen, Sect Expt Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[3] Univ Tubingen, Sect Nephrol & Hypertens, Dept Internal Med, D-72076 Tubingen, Germany
[4] Siemens Med Solut, Dept Magnet Resonance, Erlangen, Germany
关键词
D O I
10.1148/radiol.2423060209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively demonstrate the feasibility of quantifying the glomerular filtration rate ( GFR) by assessing the renal clearance of gadolinium-based contrast medium from the extracellular fluid volume in healthy volunteers. Materials and Methods: The study was approved by the ethics committee and the governmental drug administration department ( registration number 4030139, EudraCT number 2004-002969-20, study protocol number 318/2004). Informed consent was obtained from 16 healthy volunteers ( six female, 10 male; mean age, 24.5 years +/- 2.8 [ standard deviation]). Thirteen volunteers ( four women, nine men; mean age, 24.8 years +/- 2.7; range, 23-30 years) successfully contributed to the study. The GFR was assessed by recording the renal clearance of gadobutrol ( 3.75 mL, approximately 0.05 mmol per kilogram of body weight) at navigator-gated turbo fast low-angle shot magnetic resonance ( MR) imaging. Time-signal intensity curves were constructed from manually drawn regions of interest in the liver, spleen, and renal cortex, and the GFR was calculated by using exponential fitting. Simultaneously obtained iopromide clearance measurements were the reference standard. Statistical evaluations included Bland-Altman plotting and analysis of the relative deviation from iopromide clearance. Results: Evaluation of liver regions of interest revealed the lowest mean of paired differences from the iopromide clearance measurements ( -5.9 mL/min per 1.73 m(2) +/- 14.6), with a mean GFR of 109.0 mL/min per 1.73 m(2) +/- 17.1 ( 134.1 mL/min per 1.73 m(2) +/- 35.4 for spleen, 100.7 mL/min per 1.73 m(2) +/- 25.1 for renal cortex) compared with a mean GFR of 103.1 mL/min per 1.73 m(2) +/- 9.4 measured by using iopromide clearance. The maximum deviation of MR-determined gadobutrol clearance values from iopromide clearance values was 29.2%. The mean disposition half-life of gadobutrol measured in the liver was 83.0 minutes +/- 14.2 ( 72.4 minutes +/- 20.2 in spleen, 92.6 minutes +/- 23.7 in renal cortex). Conclusion: The described MR imaging method enables absolute quantification of the GFR after routine contrast material-enhanced MR imaging.
引用
收藏
页码:783 / 790
页数:8
相关论文
共 50 条
  • [31] CLINICAL ASSESSMENT OF GLOMERULAR FILTRATION RATE BY DIFFERENT FORMS OF CREATININE CLEARANCE AND A MODIFIED URINARY PHENOLSULPHONPHTHALEIN EXCRETION TEST
    HEALY, JK
    AMERICAN JOURNAL OF MEDICINE, 1968, 44 (03): : 348 - &
  • [32] Assessment of glomerular filtration rate measurement in dogs using dynamic contrast CT compared to serum iohexol clearance
    Kaenkangploo, Duangdaun
    Kampa, Naruepon
    Jitpean, Supranee
    Seesupa, Suvaluk
    Yongvanit, Karn
    VETERINARY RADIOLOGY & ULTRASOUND, 2022, 63 (01) : 38 - 46
  • [33] ASSESSMENT OF GLOMERULAR-FILTRATION RATE IN NORMAL DOGS - ANALYSIS OF THE CR-51-EDTA CLEARANCE AND ITS RELATION TO SEVERAL ENDOGENOUS PARAMETERS OF GLOMERULAR-FILTRATION
    VANDENBROM, WE
    BIEWENGA, WJ
    RESEARCH IN VETERINARY SCIENCE, 1981, 30 (02) : 152 - 157
  • [34] Assessment of glomerular filtration rate in normally hydrated and dehydrated dromedary camel by plasma exogenous creatinine clearance test
    Kamili, Asma
    Bengoumi, Mohammed
    Oukessou, Mohamed
    Faye, Bernard
    Lefebvre, Herve P.
    EMIRATES JOURNAL OF FOOD AND AGRICULTURE, 2013, 25 (04): : 314 - 319
  • [35] Assessment of aminoglycoside dosing and estimated glomerular filtration rate in determining gentamicin and tobramycin area under the curve and clearance
    Lim, A. K. H.
    Mathanasenarajah, G.
    Larmour, I.
    INTERNAL MEDICINE JOURNAL, 2015, 45 (03) : 319 - 329
  • [36] ACCURATE ASSESSMENT OF THE GLOMERULAR FILTRATION RATE (GFR) IN KIDNEY TRANSPLANT RECIPIENTS USING BAYESIAN ESTIMATION OF THE IOHEXOL CLEARANCE
    Besombes, J.
    Riff, C.
    Benz-De Bretagne, I.
    Gatault, P.
    Barbet, C.
    Buchler, M.
    Halimi, J. M.
    Barin-Le Guellec, C.
    TRANSPLANT INTERNATIONAL, 2020, 33 : 6 - 6
  • [37] Long-term precision of glomerular filtration rate measurements using Cr-51-EDTA plasma clearance
    Blake, GM
    Roe, D
    Lazarus, CR
    NUCLEAR MEDICINE COMMUNICATIONS, 1997, 18 (08) : 776 - 784
  • [38] ASSESSMENT OF GLOMERULAR-FILTRATION RATE (GFR) AND EXTRACELLULAR FLUID VOLUME (ECF) IN THE PERIOPERATIVE PHASE
    KLETTER, K
    LACKNER, F
    ZIMPFER, M
    ANAESTHESIST, 1985, 34 (11): : 600 - 606
  • [39] ASSESSMENT OF RENAL-FUNCTION BY SERUM CREATININE AND CREATININE CLEARANCE - GLOMERULAR-FILTRATION RATE ESTIMATED BY 4 PROCEDURES
    VANLENTE, F
    SUIT, P
    CLINICAL CHEMISTRY, 1989, 35 (12) : 2326 - 2330
  • [40] A comparison of serum creatinine, cystatin C and iohexol clearance for the assessment of glomerular filtration rate in patients with functional thyroid disease
    Manghat, PAK
    Barron, JL
    Wilcox, AH
    Hyer, SL
    Rodin, DA
    Xavier, FR
    CLINICA CHIMICA ACTA, 2005, 355 : S257 - S258