A procedure was established for the determination of ethanol in water samples by isotope dilution analysis. After spiking the sample with labelled [C-13(2)]ethanol, it was analysed by gas chromatography-combustion-isotope ratio mass spectrometry. Results are reported for two certified reference materials and also ethanol solutions prepared for a CITAC (Co-operation on International Traceability in Analytical Chemistry) interlaboratory comparison. The certified reference materials were certified using the dichromate titration method at nominal levels of 80 and 200 mg per 100 mL. The CITAC solutions were prepared gravimetrically at nominal levels of 50, 80 and 200 mg per 100 mL. The results of the analysis agree well to within 0.5% of the gravimetric values of the different samples. The relative expanded standard uncertainties (with a coverage factor equal to 2) associated with the results varied between 0.18 and 0.37%, a range that encompassed the gravimetric values for the different samples. A complete uncertainty budget was also drawn up so that the different contributions could be identified and quantified. The main contributions were due to variations in the measured isotope amount ratios and a 'between' blend component introduced to quantify the contribution of factors such as the degree of matching of the isotope amount ratios between standards and samples used in the isotope dilution analysis.
引用
收藏
页码:2189 / 2195
页数:7
相关论文
共 50 条
  • [41] Low Temperature Catalytic Combustion Reactors for High Precision Carbon Isotope Measurements in Gas Chromatography Combustion Isotope Ratio Mass Spectrometry
    Tobias, Herbert J.
    Jones, Andrew
    Spanjers, Charlie
    Bowers, Larry
    Brenna, J. Thomas
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (04) : 2901 - 2907
  • [42] Isotope ratio monitoring gas chromatography mass spectrometry of D H by high temperature conversion isotope ratio mass spectrometry
    Hilkert, AW
    Douthitt, CB
    Schlüter, HJ
    Brand, WA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (13) : 1226 - 1230
  • [43] Analysis of exogenous dehydroepiandrosterone excretion in urine by gas chromatography/combustion/isotope ratio mass spectrometry
    Ueki, M
    Okano, M
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (22) : 2237 - 2243
  • [44] Determination of urea kinetics by isotope dilution with [C-13]urea and gas chromatography isotope ratio mass spectrometry (GC-IRMS) analysis
    Kloppenburg, WD
    Wolthers, BG
    Stellaard, F
    Elzinga, H
    Tepper, T
    deJong, PE
    Huisman, RM
    [J]. CLINICAL SCIENCE, 1997, 93 (01) : 73 - 80
  • [45] Bias estimation in the certification of steroid reference materials for carbon isotope delta measurements via elemental analyser and gas chromatography-combustion-isotope ratio mass spectrometry
    Merrick, Jeffrey P.
    Liu, Fong-Ha
    Lewin, Mark
    Iavetz, Raluca
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (10)
  • [46] Analysis of 13C labeling enrichment in microbial culture applying metabolic tracer experiments using gas chromatography-combustion-isotope ratio mass spectrometry
    Heinzle, Elmar
    Yuan, Yongbo
    Kumar, Sathish
    Wittmann, Christoph
    Gehre, Matthias
    Richnow, Hans-Herrmann
    Wehrung, Patrick
    Adam, Pierre
    Albrecht, Pierre
    [J]. ANALYTICAL BIOCHEMISTRY, 2008, 380 (02) : 202 - 210
  • [47] Comparison of gas chromatography and liquid chromatography mass spectrometric measurements for high accuracy analysis of cholesterol in human serum by isotope dilution mass spectrometry
    Briche, CSJW
    Carter, D
    Webb, KS
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (09) : 848 - 853
  • [48] Comparison of liquid chromatography-isotope ratio mass spectrometry (LC/IRMS) and gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) for the determination of collagen amino acid δ13C values for palaeodietary and palaeoecological reconstruction
    Dunn, Philip J. H.
    Honch, Noah V.
    Evershed, Richard P.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 2995 - 3011
  • [49] Development of an analytical method for the determination of the misuse in sports of boldenone through the analysis of urine by on-line coupling liquid chromatography-gas chromatography-combustion-isotope ratio mass spectrometry
    Toledano, R. M.
    Diaz-Plaza, E. M.
    Cortes, J. M.
    Aragon, A.
    Vazquez, A. M.
    Villen, J.
    Munoz-Guerra, J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1370 : 171 - 178
  • [50] High accuracy method for the application of isotope dilution to gas chromatography/mass spectrometric analysis of gases
    Milton, MJT
    Wang, J
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (23) : 2621 - 2625