Detailed analysis on part load ratio characteristics and cooling energy saving of chiller staging in an office building

被引:49
|
作者
Seo, Byeong Mo [1 ]
Lee, Kwang Ho [2 ]
机构
[1] Hanbat Natl Univ, Grad Sch, Daejeon, South Korea
[2] Hanbat Natl Univ, Dept Architectural Engn, Daejeon, South Korea
关键词
Commercial building; Part load ratio; Chiller staging; Coefficient of performance; EnergyPlus;
D O I
10.1016/j.enbuild.2016.03.067
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Commercial buildings account for significant portions of the total building energy in Korea and thus a variety of research on the chiller operation was carried out thus far. However, most of the researches were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in the existing studies. In this study, the part load ratio and the operating characteristics of vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. In addition, the energy consumption among different chiller staging schemes was comparatively analyzed. As a result, significant portions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range of 0 through 50% and thus the energy consumption was significantly affected by the chiller COP (Coefficient of Performance) at low part load conditions, indicating that the chiller operation at the part load is an important factor in commercial buildings. In addition, utilizing sequential chiller staging scheme can save annual cooling energy usage by more than 10.3% compared to operating a single chiller. For further reduction in cooling energy, applying the sequential control chiller staging during the intermediate season and applying the uniform control chiller staging algorithm during the cooling season is considered to be the optimal control algorithm for maximum efficiency of chillers. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:309 / 322
页数:14
相关论文
共 50 条
  • [41] Energy saving obtainable by applying a commercially available M-cycle evaporative cooling system to the air conditioning of an office building in North Italy
    Zanchini, Enzo
    Naldi, Claudia
    [J]. ENERGY, 2019, 179 : 975 - 988
  • [42] Air conditioning energy consumption measurement and saving strategy analysis for an office building in hot summer and cold winter area
    Ran, Bin
    Qiu, Shuting
    Zhang, Ying
    Zeng, Li
    Zhu, Jianming
    Xiang, Zhifeng
    Long, Jibo
    [J]. ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (01) : 73 - 97
  • [43] Analysis of reduction of energy demands for Zero Emission Renovated Office Building by using thermal mass and ventilative cooling
    Alonso, Maria Justo
    Mathisen, Hans Martin
    [J]. 11TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB2017), 2017, 132 : 592 - 597
  • [44] SPECTRAL ANALYSIS OF COINCIDENT WEATHER DATA FOR APPLICATION AND BUILDING HEATING, COOLING LOAD AND ENERGY CONSUMPTION CALCULATION
    CUMALI, ZO
    [J]. ASHRAE JOURNAL, 1970, 12 (06): : 42 - &
  • [45] Thermal Analysis of Wall and Window Glass Materials for Cooling Load Reduction in Green Energy Building Design
    KiranKumar, G.
    Saboor, S.
    Babu, T. P. Ashok
    [J]. MATERIALS TODAY-PROCEEDINGS, 2017, 4 (09) : 9514 - 9518
  • [46] Key prescriptive parameters analysis of the new china building energy code based on saving to investment ratio methodology
    Zhang, Shicong
    Jiang, Yiqiang
    Xu, Wei
    Liu, Zongjiang
    Sun, Deyu
    [J]. INDOOR AND BUILT ENVIRONMENT, 2017, 26 (01) : 78 - 91
  • [47] Feasibility study of a water-to-air heat pipe based heat exchanger for cooling load reduction and energy saving in the office buildings: A simulation study
    Ahmadzadehtalatapeh, M.
    [J]. SCIENTIA IRANICA, 2017, 24 (03) : 1040 - 1050
  • [48] Dynamic forecast of cooling load and energy saving potential based on Ensemble Kalman Filter for an institutional high-rise building with hybrid ventilation
    Hou, Danlin
    Lin, Cheng-Chun
    Katal, Ali
    Wang, Liangzhu
    [J]. BUILDING SIMULATION, 2020, 13 (06) : 1259 - 1268
  • [49] Dynamic forecast of cooling load and energy saving potential based on Ensemble Kalman Filter for an institutional high-rise building with hybrid ventilation
    Danlin Hou
    Cheng-Chun Lin
    Ali Katal
    Liangzhu (Leon) Wang
    [J]. Building Simulation, 2020, 13 : 1259 - 1268
  • [50] Calibrating detailed building energy simulation programs with measured data - Part II: Application, to three case study office buildings (RP-1051)
    Reddy, T. Agami
    Maor, Itzhak
    Panjapornpon, Chanin
    [J]. HVAC&R RESEARCH, 2007, 13 (02): : 243 - 265