Experimental performance comparison of adiabatic and internally-cooled membrane dehumidifiers

被引:20
|
作者
Annadurai, Gurubalan [1 ]
Tiwari, Shaligram [1 ]
Maiya, M. P. [1 ]
机构
[1] Indian Inst Technol Madras, Dept Mech Engn, Madras 600036, Tamil Nadu, India
关键词
internally cooled membrane dehumidifier; liquid desiccant dehumidification; moisture removal rate; latent effectiveness; experimental analysis; ENERGY EXCHANGERS; MASS-TRANSFER; LIQUID; SYSTEM; DESIGN;
D O I
10.1093/ijlct/cty020
中图分类号
O414.1 [热力学];
学科分类号
摘要
Humidity control of indoor space using the conventional air conditioning system is energy intensive. The liquid desiccant dehumidifier, which operates on low grade energy sources, is one of the energy efficient alternatives for humidity control. Membrane dehumidifiers avoid the desiccant carryover and hence are preferred over the packed bed dehumidifiers. However, their performance is lower due to the additional resistance in the membrane. Internal cooling is one way to improve the performance of the membrane dehumidifier and the present study experimentally investigates such a dehumidifier. The operating parameters considered are specific humidity, mass flow rate, temperature and of inlet air. The performances of the adiabatic and internally cooled dehumidifiers are presented in terms of moisture removal rate and latent effectiveness. It is found that these are higher by 60 and 50%, respectively, for the internally cooled dehumidifier.
引用
收藏
页码:240 / 249
页数:10
相关论文
共 50 条
  • [21] Entropy and exergy analysis of an internally-cooled membrane liquid desiccant dehumidifier
    Liang, Cai-Hang
    Li, Nan-Feng
    Huang, Si-Min
    ENERGY, 2020, 192
  • [22] Experimental analysis of a novel internally-cooled dehumidifier with self-cooled liquid desiccant
    Lun, Wei
    Li, Kuining
    Liu, Bin
    Zhang, Hongji
    Yang, Yuxiao
    Yang, Cheng
    BUILDING AND ENVIRONMENT, 2018, 141 : 117 - 126
  • [23] Performance analysis of an internally-cooled plate membrane liquid desiccant dehumidifier (IMLDD): An analytical solution approach
    Huang, Si-Min
    Yang, Minlin
    Hu, Bing
    Tao, Shi
    Qin, Frank G. F.
    Weng, Wanliang
    Wang, Wenhao
    Liu, Jian
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 119 : 577 - 585
  • [24] Cooling and dehumidification performance analysis of internally-cooled liquid desiccant absorbers
    Khan, AY
    APPLIED THERMAL ENGINEERING, 1998, 18 (05) : 265 - 281
  • [25] Performance comparison of an adiabatic and an internally cooled structured packed-bed dehumidifier
    Bansal, Pradeep
    Jain, Sanjeev
    Moon, Choon
    APPLIED THERMAL ENGINEERING, 2011, 31 (01) : 14 - 19
  • [26] Performance study of the internally-cooled ultrasonic atomization liquid desiccant dehumidification system
    Yang, Zili
    Tao, Ruiyang
    Ni, Hui
    Zhong, Ke
    Lian, Zhiwei
    ENERGY, 2019, 175 : 745 - 757
  • [27] CONSTRUCTING, FABRICATING, AND FORMING INTERNALLY-COOLED CABLED SUPERCONDUCTORS
    OLMSTEAD, MM
    HOENIG, MO
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (01) : 922 - 924
  • [28] Internally-cooled atmospheric water harvesting enabling improved productivity
    Feng, Yaohui
    Ge, Lurong
    Li, Qian
    Wang, Ruzhu
    Ge, Tianshu
    WATER RESEARCH, 2024, 265
  • [29] THERMAL ANALYSIS OF AN INTERNALLY-COOLED METAL-CUTTING TOOL
    JEFFRIES, NP
    ZERKLE, RD
    INTERNATIONAL JOURNAL OF MACHINE TOOL DESIGN AND RESEARCH, 1970, 10 (03): : 381 - &
  • [30] EXPERIMENTAL INVESTIGATION OF AN INTERNALLY-COOLED OPEN SORPTION SYSTEM FOR AIR DEHUMIDIFICATION USING IONIC LIQUIDS
    Ricart, Cristina
    Meyer, Thomas
    Niemann, Klemens
    Kuehn, Roland
    Winker, Max
    Ziegler, Felix
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 844 - 852