Plasma human immunodeficiency virus (HIV) type 1 RNA load in men and women with advanced HIV-1 disease

被引:12
|
作者
Kalish, LA
Collier, AC
Flanigan, TP
Kumar, PN
机构
[1] New England Res Inst, Watertown, MA 02472 USA
[2] Univ Washington, Sch Med, Dept Med, Seattle, WA 98195 USA
[3] Brown Univ, Miriam Hosp, Dept Med, Providence, RI USA
[4] Georgetown Univ, Med Ctr, Dept Med, Washington, DC 20007 USA
来源
JOURNAL OF INFECTIOUS DISEASES | 2000年 / 182卷 / 02期
关键词
D O I
10.1086/315710
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Several studies of patients infected with human immunodeficiency virus (HIV) type 1 have suggested that women have lower plasma HIV-1 RNA levels than men, even when controlling for CD4 T cell levels. A cross-sectional analysis was performed in 494 patients (21% of whom were women) who enrolled in a prospective study of anemic HIV-1-infected patients requiring transfusion. The median CD4 T cell count and plasma HIV-1 RNA levels were 15 cells/mu L and 4.83 log(10) copies/mL (67,350 copies/mL), respectively. In unadjusted analyses, women had slightly higher mean log HIV-1. RNA titers than men (0.19 log(10) higher copieslml; 95% confidence interval, -0.05 to 0.44; P = .11), Adjustment for CD4 T cell count, race or ethnicity, injection drug use, and age yielded a smaller sex difference (0.13 log(10) copieslml higher in women; P = .28), In this population of patients with very advanced HIV disease, there is no evidence that women have lower HIV-1 RNA levels than men.
引用
收藏
页码:603 / 606
页数:4
相关论文
共 50 条
  • [21] Human immunodeficiency virus (HIV) type I antibodies in perinatal HIV-1 infection: Association with human HIV-1 transmission, infection, and disease progression
    Pitt, J
    Henrard, D
    FitzGerald, G
    Mofenson, L
    Lew, J
    Hillyer, G
    Mendez, H
    Cooper, E
    Hanson, C
    Rich, KC
    [J]. JOURNAL OF INFECTIOUS DISEASES, 2000, 182 (04): : 1243 - 1246
  • [22] Primary human immunodeficiency virus type 1 (HIV-1) infection during HIV-1 gag vaccination
    Balamurugan, Arumugam
    Lewis, Martha J.
    Kitchen, Christina M. R.
    Robertson, Michael N.
    Shiver, John W.
    Daar, Eric S.
    Pitt, Jacqueline
    Ali, Ayub
    Ng, Hwee L.
    Currier, Judith S.
    Yang, Otto O.
    [J]. JOURNAL OF VIROLOGY, 2008, 82 (06) : 2784 - 2791
  • [23] MYOPATHY WITH HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 (HIV-1) INFECTION - HIV-1 OR ZIDOVUDINE
    TILL, M
    MACDONELL, KB
    [J]. ANNALS OF INTERNAL MEDICINE, 1990, 113 (07) : 492 - 494
  • [24] Preliminary evaluation of human immunodeficiency virus type 1 (HIV-1) immunogen in children with HIV-1 infection
    Sei, S
    Sandelli, SL
    Theofan, G
    Ratto-Kim, S
    Kumagai, M
    Loomis-Price, LD
    Cox, JH
    Jarosinski, P
    Walsek, CM
    Brouwers, P
    Venzon, DJ
    Xu, J
    Pizzo, PA
    Moss, RB
    Robb, ML
    Wood, LV
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1999, 180 (03): : 626 - 640
  • [25] Correlation between Human Immunodeficiency Virus Type 1 (HIV-1) RNA Measurements Obtained with Dried Blood Spots and Those Obtained with Plasma by Use of Nuclisens EasyQ HIV-1 and Abbott RealTime HIV Load Tests
    Garrido, Carolina
    Zahonero, Natalia
    Corral, Angelica
    Arredondo, Miguel
    Soriano, Vincent
    de Mendoza, Carmen
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (04) : 1031 - 1036
  • [26] Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT
    Swanson, P
    de Mendoza, C
    Joshi, Y
    Golden, A
    Hodinka, RL
    Soriano, V
    Devare, SG
    Hackett, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (08) : 3860 - 3868
  • [27] A SIMPLIFIED METHOD FOR QUANTITATION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 (HIV-1) RNA IN PLASMA - CLINICAL CORRELATES
    STRICKER, RB
    ZHU, YS
    ELSWOOD, BF
    [J]. RESEARCH IN VIROLOGY, 1995, 146 (02): : 151 - 158
  • [28] Comparison of the artus HIV-1 QS-RGQ and VERSANT HIV-1 RNA 1.0 assays for quantitative detection of human immunodeficiency virus type 1 in plasma samples
    Dvir, Roee
    Canducci, Filippo
    Racca, Sara
    Rolla, Serena
    Stucchi, Sonia
    Clementi, Massimo
    [J]. NEW MICROBIOLOGICA, 2015, 38 (03): : 337 - 344
  • [29] Simian immunodeficiency virus engrafted with human immunodeficiency virus type 1 (HIV-1)-specific ipitopes: Replication, neutralization, and survey of HIV-1-positive plasma
    Yuste, E
    Sanford, HB
    Carmody, J
    Bixby, J
    Little, S
    Zwick, MB
    Greenough, T
    Burton, DR
    Richman, DD
    Desrosiers, RC
    Johnson, WE
    [J]. JOURNAL OF VIROLOGY, 2006, 80 (06) : 3030 - 3041
  • [30] Comparative analysis of commercial assays for the detection and quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma from patients infected with HIV-1 subtype C
    Hoesley, CJ
    Allen, SA
    Raper, JL
    Musonda, R
    Niu, YF
    Gao, F
    Squires, KE
    Aldrovandi, GM
    [J]. CLINICAL INFECTIOUS DISEASES, 2002, 35 (03) : 323 - 325