Compositing water samples for analysis of volatile organic compounds

被引:3
|
作者
Lopes, TJ
Fallon, JD
Maluk, TL
机构
[1] US Geol Survey, Rapid City, SD 57702 USA
[2] US Geol Survey, Mounds View, MN 55112 USA
[3] US Geol Survey, Columbia, SC 29210 USA
来源
关键词
D O I
10.1061/(ASCE)0733-9372(2000)126:8(769)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate mean concentrations of volatile organic compounds (VOCs) can easily and economically be obtained from a single VOC analysis by using proven methods of collecting representative, discrete water samples and compositing them with a gas-tight syringe. The technique can be used in conjunction with chemical analysis by a conventional laboratory, field-portable equipment, or a mobile laboratory. The type of mean concentration desired depends on the objectives of monitoring. For example, flow-weighted mean VOC concentrations can be used to estimate mass loadings in wastewater and urban storm water, and spatially integrated mean VOC concentrations can be used to assess sources of drinking water (e.g., reservoirs and rivers). The mean error in a discrete sample due to compositing is about 2% for most VOC concentrations greater than 0.1 mu g/L. The total error depends on the number of discrete samples comprising the composite sample and precision of the chemical analysis.
引用
收藏
页码:769 / 773
页数:5
相关论文
共 50 条
  • [21] ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN WATER, WASTEWATER AND AN INDUSTRIAL EFFLUENT
    LEINSTER, P
    MCINTYRE, AE
    LESTER, JN
    PERRY, R
    [J]. CHEMOSPHERE, 1981, 10 (03) : 291 - 301
  • [22] Analysis of volatile organic compounds in waste water by headspace/GC/MS
    Gu, Yueling
    Hu, Gengyuan
    Liu, Qing
    [J]. Zhejiang Daxue Xuebao (Ziran Kexue Ban)/Journal of Zhejiang University (Natural Science Edition), 1997, 31 (03): : 405 - 407
  • [23] GC-MS ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN WATER
    BEGGS, DP
    [J]. AMERICAN LABORATORY, 1978, 10 (07) : 81 - &
  • [24] Determination of very volatile organic compounds in Water samples by purge and trap analysis with a needle-type extraction device
    Ueta, Ikuo
    Mitsumori, Tomoki
    Suzuki, Yasutada
    Kawakubo, Susumu
    Saito, Yoshihiro
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1397 : 27 - 31
  • [25] SIMPLIFIED DETERMINATION OF VOLATILE ORGANIC-COMPOUNDS IN WATER SAMPLES USING ACTIVE-CARBON
    TAKEUCHI, R
    UENO, H
    NAITO, K
    FUJIKI, Y
    [J]. BUNSEKI KAGAKU, 1995, 44 (08) : 651 - 657
  • [26] Development of a Water Matrix Certified Reference Material for Volatile Organic Compounds Analysis in Water
    Fang, Liping
    Huang, Linyan
    Yang, Gang
    Jiang, Yang
    Liu, Haiping
    Lu, Bingwen
    Zhao, Yaxian
    Tian, Wen
    [J]. MOLECULES, 2021, 26 (14):
  • [27] Static headspace analysis of volatile organic compounds in soil and vegetation samples for site characterization
    Alvarado, JS
    Rose, C
    [J]. TALANTA, 2004, 62 (01) : 17 - 23
  • [28] ASSESSMENT OF THE STABILITY OF VOLATILE ORGANIC-COMPOUNDS IN AQUEOUS SAMPLES
    COLLANTES, ER
    BERNTSSON, M
    DUNN, WJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 74 - ENVR
  • [29] Volatile organic compounds related to Chlamydia trachomatis in urogenital samples
    Rubio Sanchez, R.
    Cristina, U. A.
    Rocio, R. R.
    [J]. CLINICA CHIMICA ACTA, 2024, 558
  • [30] Investigation of Sorption Microsystems as Reference Samples of Volatile Organic Compounds
    I. A. Platonov
    I. N. Kolesnichenko
    E. A. Novikova
    L. V. Pavlova
    [J]. Measurement Techniques, 2019, 62 : 646 - 650