Minimization of optical non-linearities in Fourier transform-infrared microspectroscopic imaging

被引:14
|
作者
Budevska, BO [1 ]
机构
[1] Dupont Co, Expt Stn, Agr Enterprise, Wilmington, DE 19880 USA
关键词
FT-IR microscopy; focal-plane array; optical non-linearities;
D O I
10.1016/S0924-2031(00)00078-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the FT-IR microspectroscopic imaging measurements of 5-mu m diameter particles and demonstrates the associated optical non-linearities, due to chromatic aberration and diffraction. FT-IR microscopes with single-element detector use image masking in order to minimize the optical effect due to diffraction. Image masking cannot be used in the focal-plane array detector microscopes. The work presented here demonstrates that, through the application of multivariate curve resolution (MCR), the chemically significant information can be separated from the optical non-linearities, An improvement of the spatial resolution is achieved through the use of multivariate images of individual components, compared to univariate images at long wavelength. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:37 / 45
页数:9
相关论文
共 50 条
  • [31] Effects of transforming growth factor-β deficiency on bone development:: A Fourier transform-infrared imaging analysis
    Atti, E
    Gomez, S
    Wahl, SM
    Mendelsohn, R
    Paschalis, E
    Boskey, AL
    BONE, 2002, 31 (06) : 675 - 684
  • [32] APPLICATION OF HYPHENATED FOURIER TRANSFORM-INFRARED TECHNIQUES TO ENVIRONMENTAL-ANALYSIS
    GURKA, DF
    PYLE, SM
    FARNHAM, I
    TITUS, R
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (08) : 339 - 344
  • [33] RAMAN MICROPROBE AND FOURIER TRANSFORM-INFRARED MICROSAMPLING STUDIES OF THE MICROSTRUCTURE OF GALLSTONES
    ISHIDA, H
    KAMOTO, R
    UCHIDA, S
    ISHITANI, A
    OZAKI, Y
    IRIYAMA, K
    TSUKIE, E
    SHIBATA, K
    ISHIHARA, F
    KAMEDA, H
    APPLIED SPECTROSCOPY, 1987, 41 (03) : 407 - 412
  • [35] Review of mid-infrared Fourier transform-infrared spectroscopy applications for bacterial detection
    Burgula, Y.
    Khali, D.
    Kim, S.
    Krishnan, S. S.
    Cousin, M. A.
    Gore, J. P.
    Reuhs, B. L.
    Mauer, L. J.
    JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2007, 15 (02): : 146 - 175
  • [36] USE OF FOURIER TRANSFORM-INFRARED SPECTROSCOPY TO DIFFERENTIATE CLINICALLY RELEVANT BACTERIA
    Ines Nieto, Laura
    Silvia Donolo, Ana
    Javier Bava, Amadeo
    Miguel Yantorno, Osvaldo
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2004, 38 (03): : 289 - 295
  • [37] Study on dietary fibre by Fourier transform-infrared spectroscopy and chemometric methods
    Chylinska, Monika
    Szymanska-Chargot, Monika
    Kruk, Beata
    Zdunek, Artur
    FOOD CHEMISTRY, 2016, 196 : 114 - 122
  • [38] CHARACTERIZATION OF TOBACCO LIGNIN BY ANALYTICAL PYROLYSIS AND FOURIER TRANSFORM-INFRARED SPECTROSCOPY
    FAIX, O
    BREMER, J
    MEIER, D
    FORTMANN, I
    SCHEIJEN, MA
    BOON, JJ
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1992, 22 (03) : 239 - 259
  • [39] COMPOSTING OF OIL PALM BIOMASS: FOURIER TRANSFORM-INFRARED AND THERMOGRAVIMETRY ANALYSES
    Abu Hassan, Norhasmillah
    Wei, Puah Chiew
    Ibrahim, Nor Azowa
    Baharuddin, Azhari Samsu
    May, Choo Yuen
    JOURNAL OF OIL PALM RESEARCH, 2015, 27 (03): : 241 - 249
  • [40] Optical non-linearities related to trions in quantum wells and quantum dots
    Puls, J
    Akimov, IA
    Henneberger, F
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2002, 234 (01): : 304 - 312