Burn-up credit in criticality safety of PWR spent fuel

被引:3
|
作者
Mahmoud, Rowayda F. [1 ]
Shaat, Mohamed K. [2 ]
Nagy, M. E. [3 ]
Agamy, S. A. [3 ]
Abdelrahman, Adel A. [1 ]
机构
[1] Atom Energy Author, Nucl Res Ctr, Dept Met, Cairo, Egypt
[2] Atom Energy Author, Nucl Res Ctr, Reactors Dept, Cairo, Egypt
[3] Univ Alexandria, Nucl & Radiat Dept, Cairo, Egypt
关键词
Compendex;
D O I
10.1016/j.nucengdes.2014.09.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The criticality safety calculations were performed for a proposed design of a wet spent fuel storage pool. This pool will be used for the storage of spent fuel discharged from a typical pressurized water reactor (PWR). The mathematical model based on the international validated codes, WIMS-5 and MCNP-5 were used for calculating the effective multiplication factor, k(eff), for the spent fuel stored in the pool. The data library for the multi-group neutron microscopic cross-sections was used for the cell calculations. The keff was calculated for several changes in water density, water level, assembly pitch and burn-up with different initial fuel enrichment and new types and amounts of fixed absorbers. Also, k(eff) was calculated for the conservative fresh fuel case. The results of the calculations confirmed that the effective multiplication factor for the spent fuel storage is sub-critical for all normal and abnormal states. The future strategy for the burn-up credit recommends increasing the fuel burn-up to a value >60.0 GWD/MTU, which requires new fuel composition and new fuel cladding material with the assessment of the effects of negative reactivity build up. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:628 / 633
页数:6
相关论文
共 50 条