Scanning Laser Doppler Vibrometer measurements for vibrating beam model updating

被引:0
|
作者
Stanbridge, AB [1 ]
Ewins, DJ [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Mech Engn, London SW7 2BX, England
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The response mode shape of a uniform beam is, in general, a polynomial function of distance along the beam, of which, as is shown, only four of the polynomial coefficients are independent. Ratios involving the other coefficients can therefore, in principle, be used to determine its density/stiffness ratio, and to confirm that it is, indeed, uniform. A scanning Laser Doppler Vibrometer is particularly useful for measuring mode shapes because the required polynomial coefficients can be derived directly. Practical trials on uniform and non-uniform beams have shown some promise. The lowest frequency modes of vibration are not normally satisfactory, because the mode shapes do not involve higher polynomial components. The process is one of limited accuracy and is affected by numerical instabilities, the paper includes some investigation of these problems.
引用
收藏
页码:1498 / 1504
页数:7
相关论文
共 50 条
  • [21] Nonperturbing measurements of spatially distributed underwater acoustic fields using a scanning laser Doppler vibrometer
    Harland, AR
    Petzing, JN
    Tyrer, JR
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (01): : 187 - 195
  • [22] LASER DOPPLER SCANNING OF THE VIBRATING TYMPANIC MEMBRANE
    TOREMALM, NG
    [J]. ACTA OTO-LARYNGOLOGICA, 1988, : 52 - 55
  • [23] Establishing correction solutions for scanning laser Doppler vibrometer measurements affected by sensor head vibration
    Halkon, Ben J.
    Rothberg, Steve J.
    [J]. Mechanical Systems and Signal Processing, 2021, 150
  • [24] Analysis of the Phase Change of a Laser Beam in a Laser Doppler Vibrometer Due To the Sound Field Radiated From Structures Vibrating Underwater
    Kil, Hyun-Gwon
    Jarzynski, Jacek
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2008, 27 (04): : 178 - 182
  • [25] Continuous scanning laser Doppler vibrometer for mode shape analysis
    La, JP
    Choi, J
    Wang, SY
    Kim, K
    Park, K
    [J]. OPTICAL ENGINEERING, 2003, 42 (03) : 730 - 737
  • [26] Normal mode testing using a scanning Laser Doppler Vibrometer
    Brehmer, A
    [J]. FOURTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2000, 4072 : 184 - 193
  • [27] Two-axis-scanning laser Doppler vibrometer for microstructure
    Ngoi, BKA
    Venkatakrishnan, K
    Tan, B
    Noël, N
    Shen, ZW
    Chin, CS
    [J]. OPTICS COMMUNICATIONS, 2000, 182 (1-3) : 175 - 185
  • [28] A novel algorithm for determining the pose of a scanning laser Doppler vibrometer
    Liu, Cuihong
    Zang, Chaoping
    Zhou, Biao
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (02)
  • [29] Two-axis-scanning Laser Doppler Vibrometer for Microstructure
    Ngoi, BKA
    Venkatakrishnan, K
    Tan, B
    Noël, N
    Shen, ZW
    Chin, CS
    [J]. FOURTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2000, 4072 : 414 - 421
  • [30] Characterization of acoustic materials using the scanning laser Doppler vibrometer
    Vanlanduit, Steve
    Vanherzeele, Joris
    Vuye, Cedric
    Guillaume, Patrick
    [J]. SEVENTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2006, 6345