Enhanced Static Modulated Fourier Transform Spectrometer for Fast Approximation in Field Application

被引:0
|
作者
Cho, Ju Yong [1 ]
Oh, Won Chun [2 ]
Jang, Won Kweon [1 ]
机构
[1] Hanseo Univ, Dept Aeronaut Elect, Seosan 31962, South Korea
[2] Hanseo Univ, Dept Adv Mat Sci & Engn, Seosan 31962, South Korea
来源
MOLECULES | 2021年 / 26卷 / 11期
关键词
InGaAs; light emitting diode; energy band gap; static modulation; spectrometer; SPECTRAL RESOLUTION;
D O I
10.3390/molecules26113312
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We discuss the data sampling frequency, the spectral resolution, and the limit for non-aliasing in the static modulated Fourier transform spectrometer based on a modified Sagnac interferometer. The measurement was performed in a very short 4 ms, which is applicable for real time field operation. The improved spectrometer characteristics were used to investigate the spectral properties of an InGaAs light emitting diode. In addition, The measured spectral peak was shifted from 6420 cm(-1) to 6365 cm(-1), as the temperature increased from 25 degrees C to 40 degrees C, when the operating current is fixed to be 0.55 A. As the applied current increased from 0.30 A to 0.55 A at room temperature, the spectral width was broadened from 316 cm(-1) to 384 cm(-1). Compared to the conventional Fourier transform spectrometer, the measured spectral width by the static modulated Fourier transform spectrometer showed a deviation less than 10%, and the spectral peak shift according to the temperature rise showed a difference within 2%.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Static Fourier-transform spectrometer based on Savart polariscope
    Zhan, G
    Oka, K
    Ishigaki, T
    Baba, N
    IMAGING SPECTROMETRY VII, 2001, 4480 : 198 - 203
  • [32] Coherent modelling and stray light in a static Fourier transform spectrometer
    Etcheto, P
    Rosak, A
    Parent, P
    Vigier, O
    OPTICAL DESIGN AND ENGINEERING, 2004, 5249 : 22 - 33
  • [33] Static, refractive and monolithic Fourier transform spectrometer: development and prototyping
    Fabio Frassetto
    Lorenzo Cocola
    Paola Zuppella
    Vania Da Deppo
    Luca Poletto
    Scientific Reports, 14
  • [34] Theory and correction of interference fringe in static Fourier transform spectrometer
    Lin Ling
    Ren Zhao
    Li Gang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (09) : 2067 - 2072
  • [35] A STATIC FOURIER-TRANSFORM SPECTROMETER BASED ON WOLLASTON PRISMS
    PADGETT, MJ
    HARVEY, AR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (04): : 2807 - 2811
  • [36] Static, refractive and monolithic Fourier transform spectrometer: development and prototyping
    Frassetto, Fabio
    Cocola, Lorenzo
    Zuppella, Paola
    Da Deppo, Vania
    Poletto, Luca
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [37] Broadband static Fourier transform mid-infrared spectrometer
    Kohler, Michael H.
    Nassl, Stefan S.
    Kienle, Patrick
    Dong, Xingchen
    Koch, Alexander W.
    APPLIED OPTICS, 2019, 58 (13) : 3393 - 3400
  • [38] FAST FOURIER TRANSFORM IN A FINITE FIELD
    POLLARD, JM
    MATHEMATICS OF COMPUTATION, 1971, 25 (114) : 365 - +
  • [39] Signal Approximation via the Gopher Fast Fourier Transform
    Ben Segal, I.
    Iwen, M. A.
    APPLICATION OF MATHEMATICS IN TECHNICAL AND NATURAL SCIENCES, 2010, 1301 : 494 - +
  • [40] Analyzing the Approximation Error of the Fast Graph Fourier Transform
    Le Magoarou, Luc
    Tremblay, Nicolas
    Gribonval, Remi
    2017 FIFTY-FIRST ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS, AND COMPUTERS, 2017, : 45 - 49