Proton dose monitoring with PET: Quantitative studies in lucite

被引:115
|
作者
Oelfke, U
Lam, GKY
Atkins, MS
机构
[1] BRITISH COLUMBIA CANC AGCY,DEPT DEV RADIOTHERAPY,VANCOUVER,BC,CANADA
[2] BRITISH COLUMBIA CANC AGCY,DEPT CLIN PHYS,VANCOUVER,BC V5Z 4E6,CANADA
[3] SIMON FRASER UNIV,DEPT COMP SCI,BURNABY,BC V5A 1S6,CANADA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1996年 / 41卷 / 01期
关键词
D O I
10.1088/0031-9155/41/1/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The feasibility of using PET for proton dose monitoring is examined here in detail. First experimental studies in a Lucite phantom have been performed at the medical TRIUMF proton beamline for proton energies of 62 MeV and 110 MeV. The proton dose delivered to the phantom ranged from 16 Gy up to 317 Gy. The induced activity was analysed 20-40 min after the irradiation with a PET scanner. The obtained depth activity profiles were compared to our calculation based on a model using available isotope production cross-section data. Both the observed absolute count rates and the activity profiles were found to agree very well with this model. Effects such as proton range straggling, inelastic nuclear interactions and the energy spectrum of the emitted positrons were studied in detail and found to change the activities by 5-10%. The lateral deposition of dose in the phantom could be very well localized by the induced activity. However, the spatial correlation between dose depth profiles and depth activity profiles was found to be poor, hence the extraction of isodose profiles from activity profiles seems to be very difficult.
引用
收藏
页码:177 / 196
页数:20
相关论文
共 50 条
  • [1] A Dose Determination Procedure by PET Monitoring in Proton Therapy
    Aiello, Marco
    Attanasi, Francesca
    Becari, Nicola
    Rosso, Valeria
    Straub, Katrin
    Del Guerra, Alberto
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3534 - 3538
  • [2] A Dose Determination Procedure by PET Monitoring in Proton Therapy: Monte Carlo Validation
    Aiello, Marco
    Attanasi, Francesca
    Belcari, Nicola
    Rosso, Valeria
    Straub, Katrin
    Del Guerra, Alberto
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3298 - 3304
  • [3] Evaluation of Distal Dose Surface with In-Room PET for Proton Therapy Monitoring
    Min, C.
    Zhu, X.
    Grogg, K.
    Winey, B.
    Fakhri, G.
    Bortfeld, T.
    Shih, H.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3860 - 3860
  • [4] Monitoring proton therapy with PET
    Paganetti, H.
    El Fakhri, G.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1051):
  • [5] Quantitative analysis of PET studies
    Weber, Wolfgang A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 (03) : 308 - 310
  • [6] Evaluation of Monte Carlo codes for dose monitoring using PET and prompt gamma imaging in proton therapy
    Robert, Charlotte
    Dedes, George
    Battistoni, Giuseppe
    Lestand, Loic
    Gueth, Pierre
    Prezado, Yolanda
    Testa, Etienne
    Montarou, Gerard
    Sarrut, David
    Buvat, Irene
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [7] MONITORING OF SPACE PROTON DOSE TO BODY ORGANS
    BILLINGS, MP
    LANGLEY, RW
    [J]. HEALTH PHYSICS, 1974, 27 (06): : 613 - 613
  • [8] Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies
    Silva-Rodriguez, Jesus
    Aguiar, Pablo
    Sanchez, Manuel
    Mosquera, Javier
    Luna-Vega, Victor
    Cortes, Julia
    Garrido, Miguel
    Pombar, Miguel
    Ruibal, Alvaro
    [J]. MEDICAL PHYSICS, 2014, 41 (05)
  • [9] Eye dose monitoring of PET/CT workers
    Walsh, C.
    O'Connor, U.
    O'Reilly, G.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1042):
  • [10] The need for quantitative PET in multicentre studies
    Adriaan A. Lammertsma
    Ronald Boellaard
    [J]. Clinical and Translational Imaging, 2014, 2 (4) : 277 - 280