Eye dose monitoring of PET/CT workers

被引:5
|
作者
Walsh, C. [1 ]
O'Connor, U. [1 ]
O'Reilly, G. [1 ]
机构
[1] St James Hosp, Dept Med Phys, Dublin 8, Ireland
来源
BRITISH JOURNAL OF RADIOLOGY | 2014年 / 87卷 / 1042期
关键词
LENS DOSIMETRY; LIMIT;
D O I
10.1259/bjr.20140373
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of the study was to measure eye dose [Hp(3)] to workers in a busy positron emission tomography (PET)/CT centre. Doses were compared with the proposed new annual dose limit of 20mSv. Methods: We used a newly designed dosemeter to measure eye dose [Hp(3)]. Eye dosemeters were worn with an adjustable headband, with the dosemeter positioned adjacent to the left eye. The whole-body dose was also recorded using electronic personal dosemeter (EPD r Mk2; Thermo Electron Corporation, Waltham, MA). Exposed staff included radiographers, nurses and healthcare assistants. Results: The radiographers received the highest exposure of the staff groups studied, with one radiographer receiving an exposure of 0.5mSv over the 3-month survey period. The estimated maximum eye dose for 1 year is approximately 2mSv. The numeric value for eye dose was compared with the numeric value for personal dose equivalent to see if one could be used as an indicator for the other. From our data, a conservative estimate of eye dose Hp(3) (mSv) can be made as being up to approximately twice the numeric value for wholebody dose [Hp(10)] (mSv). Conclusion: Eye dose was found to be well within the new proposed annual limit at our PET/CT centre. Routine whole-body dose measurements may be a useful starting point for assessing whether eye dose monitoring should be prioritized in a PET facility. Advances in knowledge: Following the proposal of a reduced eye dose limit, this article provides new measurement data on staff eye doses for PET/CT workers.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Effective dose of for medical workers operating in a PET/CT department
    Dalianis, K.
    Kollias, G.
    Gogos, K.
    Pipikos, T.
    Vogiatzis, M.
    Vlachou, F.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S664 - S665
  • [2] Video Extremity Dose Monitoring in a PET/CT Department
    Guy, M. J.
    Sellinger, J.
    Morton, R. J.
    Hall, J. R. W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S210 - S210
  • [3] A Radiation Dose Monitoring System for the PET/CT Clinic
    Palmer, Matthew
    Zhang, Da
    Barbaras, Larry
    Parker, J. Anthony
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [4] Effective dose of for medical workers operating in a PET/CT with the use of synthesis module
    Dalianis, K.
    Gogos, K.
    Kollias, G.
    Efthimiadou, R.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S454 - S455
  • [5] Occupational exposure for eye, thyroid and gonads to medical workers operating in a PET/CT facility
    Dalianis, K.
    Vlachou, F.
    Eftymiadou, R.
    Pipikos, T.
    Andreou, J.
    Kollias, G.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S448 - S449
  • [6] Occupational exposure for eye, thyroid and gonads to medical workers operating in a PET/CT facility
    Dalianis, K.
    Kollias, G.
    Vlachou, F.
    Pipikos, T.
    Vogiatzis, M.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S742 - S742
  • [7] Evaluation of wrist and finger dose of dedicated medical workers operating in PET/CT departments
    Dalianis, K.
    Vlachou, F.
    Filippi, V.
    Gogou, L.
    Kechagias, D.
    Gogos, K.
    Tsaroucha, A.
    Andreou, I.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S343 - S343
  • [8] CT Dose in Pediatric PET/CT Examinations
    Tonkopi, E.
    Ross, A.
    MacDonald, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [9] Effects of CT dose management in PET/CT
    Baun, C.
    Falch, K.
    Gerke, O.
    Braad, P. E.
    Petersen, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S204 - S204
  • [10] Impacts of Reduction of CT Radiation Dose on PET in PET/CT Imaging
    Xia, Ting
    Wang, Wenli
    Ji, Changguo
    Niu, Xiaofeng
    Ye, Hongwei
    Winkler, Mark
    Teshigawara, Manabu
    Noshi, Yasuhiro
    Gagnon, Daniel
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,