Objective: The objective of the study was to measure eye dose [Hp(3)] to workers in a busy positron emission tomography (PET)/CT centre. Doses were compared with the proposed new annual dose limit of 20mSv. Methods: We used a newly designed dosemeter to measure eye dose [Hp(3)]. Eye dosemeters were worn with an adjustable headband, with the dosemeter positioned adjacent to the left eye. The whole-body dose was also recorded using electronic personal dosemeter (EPD r Mk2; Thermo Electron Corporation, Waltham, MA). Exposed staff included radiographers, nurses and healthcare assistants. Results: The radiographers received the highest exposure of the staff groups studied, with one radiographer receiving an exposure of 0.5mSv over the 3-month survey period. The estimated maximum eye dose for 1 year is approximately 2mSv. The numeric value for eye dose was compared with the numeric value for personal dose equivalent to see if one could be used as an indicator for the other. From our data, a conservative estimate of eye dose Hp(3) (mSv) can be made as being up to approximately twice the numeric value for wholebody dose [Hp(10)] (mSv). Conclusion: Eye dose was found to be well within the new proposed annual limit at our PET/CT centre. Routine whole-body dose measurements may be a useful starting point for assessing whether eye dose monitoring should be prioritized in a PET facility. Advances in knowledge: Following the proposal of a reduced eye dose limit, this article provides new measurement data on staff eye doses for PET/CT workers.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Attenuation correction of PET cardiac data with low-dose average CT in PET/CT
    Pan, Tinsu
    Mawlawi, Osama
    Luo, Dershan
    Liu, Hui H.
    Chi, Pai-Chun M.
    Mar, Martha V.
    Gladish, Gregory
    Truong, Mylene
    Erasmus, Jeremy, Jr.
    Liao, Zhongxing
    Macapinlac, H. A.
    MEDICAL PHYSICS, 2006, 33 (10) : 3931 - 3938
  • [32] Radiation Dose to NM Techs from PET/MR and PET/CT
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (05) : 20N - 20N
  • [33] 18F-FLT PET/CT for Early Response Monitoring and Dose Escalation in Oropharyngeal Tumors
    Troost, Esther G. C.
    Bussink, Johan
    Hoffmann, Aswin L.
    Boerman, Otto C.
    Oyen, Wim J. G.
    Kaanders, Johannes H. A. M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (06) : 866 - 874
  • [34] External dosimetry and personnel monitoring for medical workers operating 18F FDG PET/CT scans
    Dalianis, K.
    Malamitsi, J.
    Gogou, L.
    Pagou, M.
    Gogos, K.
    Efthimiadou, R.
    Andreou, J.
    Georgiou, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S126 - S126
  • [35] Diagnostic value of CT, PET and combined PET/CT performed with low-dose unenhanced CT and full-dose enhanced CT in the initial staging of lymphoma
    Pinilla, I.
    Gomez-Leon, N.
    Del Campo-Del Val, L.
    Hernandez-Maraver, D.
    Rodriguez-Vigil, B.
    Jover-Diaz, R.
    Coya, J.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 55 (05): : 567 - 575
  • [36] Implementation of CT tin filter in PET-CT: dose savings and image quality evaluation for tissues and dose levels relevant to PET-CT
    Holdgaard, P.
    Bebbington, N. A.
    Christensen, K. B.
    Ostergard, L. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S227 - S227
  • [37] Implementation of a CT dose modulation methodology for 'functional mapping' PET/CT: Impact on patient dose
    Dickson, J. C.
    Endozo, R.
    Waddington, W. A.
    Bomanji, J. B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S187 - S188
  • [38] IMPLEMENTATION OF MODULATED LOW DOSE CT FOR PET/CT SCANS TO REDUCE RADIATION DOSE TO PATIENT
    Ng, W.
    Welch, J.
    Pathmaraj, K.
    Scott, A.
    INTERNAL MEDICINE JOURNAL, 2017, 47 : 33 - 33
  • [39] Survey of CT radiation dose levels during PET/CT from ACR CT Dose Index Registry
    Alessio, Adam
    Sengupta, Debapriya
    Bhargavan-Chatfield, Mythreyi
    Butler, Priscilla
    Kanal, Kalpana
    Fahey, Frederic
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [40] Dose Optimization in CT, in Nuclear Medicine and in PET-CT Procedures
    Nunes, Ana T. C.
    Vaz, Pedro
    Madeira, Paula
    2013 IEEE 3RD PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2013,