Hemin-Modified SnO2/Metglas Electrodes for the Simultaneous Electrochemical and Magnetoelastic Sensing of H2O2

被引:16
|
作者
Samourgkanidis, Georgios [1 ]
Nikolaou, Pavlos [2 ]
Gkovosdis-Louvaris, Andreas [2 ]
Sakellis, Elias [3 ]
Blana, Ioanna Maria [2 ]
Topoglidis, Emmanuel [2 ]
机构
[1] Univ Patras, Dept Chem Engn, Patras 26504, Greece
[2] Univ Patras, Dept Mat Sci, Patras 26504, Greece
[3] Natl Ctr Sci Res, Inst Nanosci & Nanotechnol, Athens 15310, Greece
来源
COATINGS | 2018年 / 8卷 / 08期
关键词
SnO2; Metglas; hemin; H2O2; cyclic voltammetry; magnetoelastic resonance; sensor; HYDROGEN-PEROXIDE; NANOPARTICLES; BIOSENSOR; OXIDE; SENSOR; TIO2; ELECTROCATALYSIS; NANOCOMPOSITES; SENSITIVITY; PERFORMANCE;
D O I
10.3390/coatings8080284
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, we present a simple and efficient method for the preparation of hemin-modified SnO2 films on Metglas ribbon substrates for the development of a sensitive magneto-electrochemical sensor for the determination of H2O2. The SnO2 films were prepared at low temperatures, using a simple hydrothermal method, compatible with the Metglas surface. The SnO2 film layer was fully characterized by X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), photoluminescence (PL) and Fourier Transform-Infrared spectroscopy (FT-IR). The properties of the films enable a high hemin loading to be achieved in a stable and functional way. The Hemin/SnO2-Metglas system was simultaneously used as a working electrode (WE) for cyclic voltammetry (CV) measurements and as a magnetoelastic sensor excited by external coils, which drive it to resonance and interrogate it. The CV scans reveal direct reduction and oxidation of the immobilized hemin, as well as good electrocatalytic response for the reduction of H2O2. In addition, the magnetoelastic resonance (MR) technique allows the detection of any mass change during the electroreduction of H2O2 by the immobilized hemin on the Metglas surface. The experimental results revealed a mass increase on the sensor during the redox reaction, which was calculated to be 767 ng/M. This behavior was not detected during the control experiment, where only the NaH2PO4 solution was present. The following results also showed a sensitive electrochemical sensor response linearly proportional to the concentration of H2O2 in the range 1 x 10(-6)-72 x 10(-6) M, with a correlation coefficient of 0.987 and detection limit of 1.6 x 10(-7) M. Moreover, the Hemin/SnO2-Metglas displayed a rapid response (30 s) to H2O2 and exhibits good stability, reproducibility and selectivity.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Study on simultaneous detection of CO and H2 with (Pd, Fe)-modified SnO2 and Pt-loaded SnO2 sensors
    Xi-Tao Yin
    Pin Lv
    Jing Li
    Journal of Materials Science: Materials in Electronics, 2018, 29 : 18935 - 18940
  • [22] Study on simultaneous detection of CO and H2 with (Pd, Fe)-modified SnO2 and Pt-loaded SnO2 sensors
    Yin, Xi-Tao
    Lv, Pin
    Li, Jing
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2018, 29 (22) : 18935 - 18940
  • [23] On the mechanism of H2O2 reduction at Prussian Blue modified electrodes
    Faculty of Chemistry, M.V. Lomonosov Moscow Stt. U., Moscow, Russia
    不详
    Electrochem. Commun., 2 (78-82):
  • [24] On the mechanism of H2O2 reduction at Prussian Blue modified electrodes
    Karyakin, AA
    Karyakina, EE
    Gorton, L
    ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (02) : 78 - 82
  • [25] Electrochemical Sensing of H2O2 at Flavin Adenine Dinucleotide/Chitosan/CNT Nanocomposite Modified Electrode
    Kumar, S. Ashok
    Chen, Szu-Ling
    Chen, Shen-Ming
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2010, 13 (10) : K83 - K86
  • [26] Probing the tunneling of electrons from SnO2 to ZnO in dye sensitization of composite SnO2/ZnO by use of generated H2O2 via reduction of O2
    Bandara, J
    Tennakone, K
    Binduhewa, P
    NEW JOURNAL OF CHEMISTRY, 2001, 25 (10) : 1302 - 1305
  • [27] H2O2 sensing in immunity
    Dietz, Karl-Josef
    Vogelsang, Lara
    NATURE PLANTS, 2022, 8 (10) : 1140 - 1141
  • [28] H2O2 sensing in immunity
    Karl-Josef Dietz
    Lara Vogelsang
    Nature Plants, 2022, 8 : 1140 - 1141
  • [29] ELECTROCHEMICAL CHARACTERISTICS OF H2O2 MICROARRAY ELECTRODES AS BASE ELEMENTS OF BIOSENSORS
    ZHU, JZ
    LIU, XH
    WU, JL
    LU, DR
    ZHANG, GX
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (04): : 277 - 280
  • [30] A comparison of electrochemical oxidation performance of PbO2 and SnO2 electrodes
    Duan, X. Y.
    Li, J. R.
    Chang, L. M.
    Yang, C. W.
    JOURNAL OF WATER REUSE AND DESALINATION, 2016, 6 (03): : 392 - 398