Failure analysis of the wall tubes of a water-tube boiler

被引:50
|
作者
Duarte, Camilo A. [1 ]
Espejo, Edgar [1 ]
Carlos Martinez, Juan [1 ]
机构
[1] Univ Nacl Colombia, Dept Mech & Mechatron Engn, Bogota, Colombia
关键词
Boiler tube; Stress corrosion cracking (SCC); Pitting corrosion; Residual stress; Finite element analysis; STRESS-CORROSION CRACKING;
D O I
10.1016/j.engfailanal.2017.05.032
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An industrial case history of the failure of the evaporator (water wall) tubes of a water-tube boiler is presented in this study. After two years in service, a leak was detected in one of the tubes over its bent section with pitting corrosion on its internal surface. Later on, the same symptoms were discovered in other tubes of the same boiler, and several tubes were extracted for failure analysis. On the basis of visual inspection, chemical analysis, microstructural examination, hardness measurements, and residual stress measurements via X-ray diffraction (XRD), the failure mechanism of the tubes was identified as stress corrosion cracking (SCC). In this paper, the results obtained from the experimental analysis are summarized, and finite element (FE) models are used to predict the residual stress due to the bending of the tube and the operational stress at the moment of failure. It was found that tensile residual stress from an inadequate stress relief treatment prior to service and high concentration of dissolved oxygen in the feed water were the main reasons for the premature failure of the boiler tubes by SCC.
引用
收藏
页码:704 / 713
页数:10
相关论文
共 50 条
  • [41] ACOUSTIC EMISSION DETECTION AND SIGNAL SOURCE ANALYSIS OF BOILER WATER WALL TUBE
    Yuan, Yilin
    Shen, Gongtian
    Shen, Yongna
    Zhang, Wenjun
    Wan, Qiang
    [J]. PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 13, 2021,
  • [42] The Temperature of a Water-Wall Tube in a Drum Boiler
    Kholshchev, V.V.
    [J]. Thermal Engineering, 1998, 45 (10): : 839 - 841
  • [43] ANALYSIS OF THE REASONS FOR THE LEAKAGE OF A BOILER WATER-WALL TUBE IN A POWER PLANT
    Guo, Ruidong
    Xue, Song
    Yang, Tao
    Liu, Xuedong
    [J]. MATERIALI IN TEHNOLOGIJE, 2020, 54 (02): : 221 - 226
  • [44] Failure analysis of bank front boiler tubes
    Khajavi, M. R.
    Abdolmaleki, A. R.
    Adibi, N.
    Mirfendereski, S.
    [J]. ENGINEERING FAILURE ANALYSIS, 2007, 14 (04) : 731 - 738
  • [45] Numerical simulations and an experimental study for optimal design of a 1500 kW water-tube condensing boiler
    Babadi, Keyvan Ahmadi
    Khorasanizadeh, Hossein
    Mirzazadeh, Ghorbanali
    Mirzazadeh, Soheil
    [J]. ENERGY, 2024, 307
  • [46] Analysis of spiral water-wall tube in once-through boiler
    [J]. Hsi An Chiao Tung Ta Hsueh, 11 (51-54):
  • [47] Condition Assessment of Boiler Water Wall Tubes using Robotics
    Vajpayee, Ankit
    Russell, David
    [J]. e-Journal of Nondestructive Testing, 2022, 27 (12):
  • [48] Fire-tube versus water-tube boilers
    Sauselein, Theodore
    [J]. Engineered Systems, 1996, 13 (06):
  • [49] Metallurgical analysis of ASME SA213 T12 boiler vertical water-wall tubes failure
    Khedr, Mahmoud
    Abd Elaziem, Walaa
    Newishy, M.
    Abdel-Aleem, H.
    [J]. ENGINEERING FAILURE ANALYSIS, 2023, 145
  • [50] EFFECTS OF USING A FOUR-RIBBED TUBE ON IMPROVING HEAT TRANSFER IN BOILER WATER WALL TUBES.
    Xu, Ren-De
    Zhang, Yu-lin
    Zhu, Caiquang
    [J]. Heat Transfer Engineering, 1985, 6 (04) : 39 - 44