Novel EFHAT system and exergy analysis with energy utilization diagram

被引:22
|
作者
Jin, HG [1 ]
Zhao, HB [1 ]
Liu, ZL [1 ]
Cai, RX [1 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100080, Peoples R China
关键词
D O I
10.1016/j.energy.2004.03.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a new type of gas turbine cycle has been proposed based on an innovative combination of a newly designed HAT cycle with an externally fired heater. In this manner, "dirty" fuels such as coal and biomass can be more efficiently used than before and the water in this cycle can be recycled. This is radically different from the conventional HAT cycle. In particular, the temperature of the clean humid air out of the turbine is not restricted by the dew point of gas. Hence, some amount of latent heat can be utilized to generate hot water being supplied to the humidifier. This will enhance the humidification ability for improving performance of the system. The new system is also analyzed by using the graphical exergy methodology based on energy-utilization diagrams (EUDs). As a result, for a turbine inlet temperature (TIT) of 1073 K, the thermal efficiency of the new system may be as high as 45.37%. The new system will effectively recover both the energy quality and quantity at the low- and middle-temperature ranges. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1983 / 1991
页数:9
相关论文
共 50 条
  • [21] Evaluation of renewable energy utilization efficiency in buildings with exergy analysis
    Zhou, Yan
    [J]. APPLIED THERMAL ENGINEERING, 2018, 137 : 430 - 439
  • [22] Sankey diagram framework for energy and exergy flows
    Soundararajan, Kamal
    Ho, Hiang Kwee
    Su, Bin
    [J]. APPLIED ENERGY, 2014, 136 : 1035 - 1042
  • [23] A new type of EFHAT power generation system with effective utilization of latent heat
    Jin, HG
    Liu, ZL
    Cai, RX
    Zha, HB
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (13) : 1231 - 1244
  • [24] Comprehensive evaluation of a novel liquid carbon dioxide energy storage system with cold recuperator: Energy, conventional exergy and advanced exergy analysis
    Liu, Xu
    Yan, Xuewen
    Liu, Xianglei
    Liu, Zhan
    Zhang, Weifeng
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 250
  • [25] Energy and exergy analysis of an ejector refrigeration system
    Untea, George Adrian
    Dobrovicescu, Alexandru
    Grosu, Lavinia
    Mladin, Emilia Cerna
    [J]. UPB Scientific Bulletin, Series D: Mechanical Engineering, 2013, 75 (04): : 111 - 126
  • [26] Evaluation and integration of energy utilization in a process system through material flow analysis coupled with exergy flow analysis
    Yang, Feifei
    Liu, Yongzhong
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2016, 103 : 334 - 347
  • [27] Exergy analysis of the United Kingdom energy system
    Hammond, GP
    Stapleton, AJ
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2001, 215 (A2) : 141 - 162
  • [28] APPLICATION OF ENERGY-DIRECTION FACTOR DIAGRAM FOR EXERGY ANALYSIS OF A DISTILLATION COLUMN
    ISHIDA, M
    OHNO, T
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1983, 16 (04) : 281 - 287
  • [29] Extension of energy-utilisation diagram to power availability for exergy loss analysis
    Bouapetch, Winit
    Tungwungwiwat, Pongsiri
    Srinophakun, Thongchai
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2013, 12 (03) : 323 - 343
  • [30] Modeling of sectoral energy and exergy utilization
    Hepbasli, A
    [J]. ENERGY SOURCES, 2005, 27 (10): : 903 - 912