Calibration of low-cost particulate matter sensors: Model development for a multi-city epidemiological study

被引:87
|
作者
Zusman, Marina [1 ]
Schumacher, Cooper S. [1 ]
Gassett, Amanda J. [1 ]
Spalt, Elizabeth W. [1 ]
Austin, Elena [1 ]
Larson, Timothy V. [2 ]
Carvlin, Graeme [1 ]
Seto, Edmund [1 ]
Kaufman, Joel D. [1 ,3 ,4 ]
Sheppard, Lianne [1 ,5 ]
机构
[1] Univ Washington, Dept Environm & Occupat Hlth Sci, Seattle, WA 98195 USA
[2] Univ Washington, Dept Civil & Environm Engn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Epidemiol, Seattle, WA 98195 USA
[5] Univ Washington, Dept Biostat, Seattle, WA 98195 USA
关键词
Low-cost monitors (LCM); Calibration; Air pollution; Fine particulate matter; Multicenter study design; Air quality system network (AQS); AIR-POLLUTION; PARTICLE COUNTER; EXPOSURE; PERFORMANCE; QUALITY; AMBIENT;
D O I
10.1016/j.envint.2019.105329
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-cost air monitoring sensors are an appealing tool for assessing pollutants in environmental studies. Portable low-cost sensors hold promise to expand temporal and spatial coverage of air quality information. However, researchers have reported challenges in these sensors' operational quality. We evaluated the performance characteristics of two widely used sensors, the Plantower PMS A003 and Shinyei PPD42NS, for measuring fine particulate matter compared to reference methods, and developed regional calibration models for the Los Angeles, Chicago, New York, Baltimore, Minneapolis-St. Paul, Winston-Salem and Seattle metropolitan areas. Duplicate Plantower PMS A003 sensors demonstrated a high level of precision (averaged Pearson's r = 0.99), and compared with regulatory instruments, showed good accuracy (cross-validated R-2 = 0.96, RMSE = 1.15 mu g/m(3) for daily averaged PM2.5 estimates in the Seattle region). Shinyei PPD42NS sensor results had lower precision (Pearson's r = 0.84) and accuracy (cross-validated R-2 = 0.40, RMSE = 4.49 mu g/m(3)). Region-specific Plantower PMS A003 models, calibrated with regulatory instruments and adjusted for temperature and relative humidity, demonstrated acceptable performance metrics for daily average measurements in the other six regions (R-2 = 0.74-0.95, RMSE = 2.46-0.84 mu g/m(3)). Applying the Seattle model to the other regions resulted in decreased performance (R-2 = 0.67-0.84, RMSE = 3.41-1.67 mu g/m(3)), likely due to differences in meteorological conditions and particle sources. We describe an approach to metropolitan region-specific calibration models for low-cost sensors that can be used with caution for exposure measurement in epidemiological studies.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [21] Calibration Method for Particulate Matter Low-Cost Sensors Used in Ambient Air Quality Monitoring and Research
    Jagatha, Janani Venkatraman
    Klausnitzer, Andre
    Chacon-Mateos, Miriam
    Laquai, Bernd
    Nieuwkoop, Evert
    van der Mark, Peter
    Vogt, Ulrich
    Schneider, Christoph
    SENSORS, 2021, 21 (12)
  • [22] Investigation of Low-Cost and Optical Particulate Matter Sensors for Ambient Monitoring
    Rogulski, Mariusz
    Badyda, Artur
    ATMOSPHERE, 2020, 11 (10)
  • [23] A Review of Low-Cost Particulate Matter Sensors from the Developers' Perspectives
    Alfano, Brigida
    Barretta, Luigi
    Del Giudice, Antonio
    De Vito, Saverio
    Di Francia, Girolamo
    Esposito, Elena
    Formisano, Fabrizio
    Massera, Ettore
    Miglietta, Maria Lucia
    Polichetti, Tiziana
    SENSORS, 2020, 20 (23) : 1 - 56
  • [24] Opportunities for Low-Cost Particulate Matter Sensors in Filter Emission Measurements
    Schwarz, Almuth D.
    Meyer, Joerg
    Dittler, Achim
    CHEMICAL ENGINEERING & TECHNOLOGY, 2018, 41 (09) : 1826 - 1832
  • [25] Suitability of Low-Cost Particulate Matter Sensors for Measurements in Ventilation Systems
    Marval, Jesus
    Medina, Luis
    Vallejo, Juan
    Tronville, Paolo
    IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [26] A Review of Literature on the Usage of Low-Cost Sensors to Measure Particulate Matter
    Raysoni, Amit U.
    Pinakana, Sai Deepak
    Mendez, Esmeralda
    Wladyka, Dawid
    Sepielak, Katarzyna
    Temby, Owen
    EARTH, 2023, 4 (01): : 168 - 186
  • [27] Evaluation of Low-Cost Particulate Matter (PM) Sensors: A Preliminary Investigation
    Qian, Defeng
    Pang, Zhihong
    O'Neill, Zheng
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [28] Laboratory and field evaluation of three low-cost particulate matter sensors
    Ghamari, Mohammad
    Soltanpur, Cinna
    Rangel, Pablo
    Groves, William A.
    Kecojevic, Vladislav
    IET WIRELESS SENSOR SYSTEMS, 2022, 12 (01) : 21 - 32
  • [29] Low-Cost Particulate Matter Sensors for Monitoring Residential Wood Burning
    Hassani, Amirhossein
    Schneider, Philipp
    Vogt, Matthias
    Castell, Nuria
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (40) : 15162 - 15172
  • [30] Field calibration of fine particulate matter low-cost sensors in a highly industrialized semi-arid conurbation
    Mariana Villarreal-Marines
    Michael Pérez-Rodríguez
    Yasmany Mancilla
    Gabriela Ortiz
    Alberto Mendoza
    npj Climate and Atmospheric Science, 7 (1)