Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning

被引:88
|
作者
Li, JS [1 ]
Pawlicki, T [1 ]
Deng, J [1 ]
Jiang, SB [1 ]
Mok, E [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 10期
关键词
D O I
10.1088/0031-9155/45/10/316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new EGS4/PRESTA Monte Carlo user code, MCDOSE, has been developed as a routine dose calculation tool for radiotherapy treatment planning. It is suitable for both conventional and intensity modulated radiation therapy. Two important features of MCDOSE are the inclusion of beam modifiers in the patient simulation and the implementation of several variance reduction techniques. Before this tool can be used reliably for clinical dose calculation, it must be properly validated. The validation for beam modifiers has been performed by comparing the dose distributions calculated by MCDOSE and the well-benchmarked EGS4 user codes BEAM and DOSXYZ. Various beam modifiers were simulated. Good agreement in the dose distributions was observed. The differences in electron cutout factors between the results of MCDOSE and measurements were within 2%. The accuracy of MCDOSE with various variance reduction techniques was tested by comparing the dose distributions in different inhomogeneous phantoms with those calculated by DOSXYZ without variance reduction. The agreement was within 1.0%. Our results demonstrate that MCDOSE is accurate and efficient for routine dose calculation in radiotherapy treatment planning, with or without beam modifiers.
引用
收藏
页码:2969 / 2985
页数:17
相关论文
共 50 条
  • [21] An overview of Monte Carlo treatment planning for radiotherapy
    Spezi, Emiliano
    Lewis, Geraint
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) : 123 - 129
  • [22] Validation of Monte Carlo Electron Dose Calculation in RayStation
    Yang, K.
    Chen, H.
    Mourtada, F.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E261 - E261
  • [23] Evaluation of a Commercial Monte Carlo Dose Calculation Algorithm for Electron Treatment Planning
    Huang, J.
    Dunkerley, D.
    Smilowitz, J.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E546 - E546
  • [24] Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning
    Huang, Jessie Y.
    Dunkerley, David
    Smilowitz, Jennifer B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 184 - 193
  • [25] Dose calculation using Monte Carlo algorithm of Monaco treatment planning system
    Li, J.
    Doemer, A.
    Harrison, A. S.
    Galvin, J. M.
    Xiao, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S674 - S674
  • [26] Is Monte Carlo Dose Calculation Method Necessary for Cyberknife Brain Treatment Planning?
    Wang, L.
    Fourkal, E.
    Hayes, S.
    Jin, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 275 - 275
  • [27] Monte-Carlo calculation of integral dose for gamma knife treatment planning
    Li, K.
    Wang, J.
    Cai, M.
    Mayr, N.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2473 - 2473
  • [28] Effect of voxel size on Monte Carlo dose calculation for IMRT treatment planning
    Mora, G
    Li, JS
    Xiong, W
    King, I
    Ma, CM
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1451 - 1451
  • [29] Study of Dose Calculation Using Monte Carlo Method in Radiotherapy
    Gao, C.
    Chi, Z.
    Liu, D.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [30] STEREOTACTIC RADIOTHERAPY FOR LUNG TUMOURS: TREATMENT PRESCRIPTION USING MONTE CARLO DOSE CALCULATION
    Bolt, R.
    Van der Schaaf, A.
    Hollander, M.
    Widder, J.
    van't Veld, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S116 - S116