Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque

被引:160
|
作者
Brand, JC [1 ]
Pienkowski, D [1 ]
Steenlage, E [1 ]
Hamilton, D [1 ]
Johnson, DL [1 ]
Caborn, DNM [1 ]
机构
[1] Univ Kentucky, Sch Med, Lexington, KY 40536 USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2000年 / 28卷 / 05期
关键词
D O I
10.1177/03635465000280051501
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to determine whether bone mineral density of the host bone, measured using conventional dual photon absorptiometry techniques, and insertion torque can predict part of the ultimate failure strength of interference screw fixation of quadrupled hamstring tendon grafts. The semitendinosus and gracilis tendons were harvested from 10 human cadaveric knees, mean age 66.5 years (range, 53 to 81). The bone tunnel was sized within 0.5 mm of the graft. The graft was fixed with a biodegradable screw (7 x 25 mm for the femur, and 9 x 25 mm for the tibia) directly against the tendon and at the joint surfaces. Tibial fixation and femoral fixation were tested to failure using a materials testing system. Bone mineral density was measured in the metaphyseal region of the tibia and femur. The results of multiple regression analyses showed that both insertion torque and bone mineral density were related to the maximum load the graft withstood. These two variables explained 77.1% of the maximum load observed. We concluded that bone mineral density measurements of the host bone site are an important determinant of postoperative graft strength and thus have an important, but previously unrecognized, clinical role in establishing individual postsurgery rehabilitation protocols. Insertion torque in this study was a useful predictor of graft fixation strength.
引用
收藏
页码:705 / 710
页数:6
相关论文
共 44 条
  • [11] Comparison of bone-patellar tendon-bone interference screw fixation and hamstring transfemoral screw fixation in anterior cruciate ligament reconstruction
    Randall, RL
    Wolf, EM
    Heilmann, MR
    Lotz, J
    ORTHOPEDICS, 1999, 22 (06) : 587 - 591
  • [12] Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?
    Ab-Lazid, Rosidah
    Perilli, Egon
    Ryan, Melissa K.
    Costi, John J.
    Reynolds, Karen J.
    JOURNAL OF BIOMECHANICS, 2014, 47 (02) : 347 - 353
  • [13] Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation
    Stalder, Michael
    Farshad, Mazda
    Snedeker, Jess G.
    Meyer, Dominik C.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (03) : 584 - 588
  • [14] Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation
    Michael Stalder
    Mazda Farshad
    Jess G. Snedeker
    Dominik C. Meyer
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 584 - 588
  • [15] STRENGTH OF ANTERIOR VERTEBRAL SCREW FIXATION IN RELATIONSHIP TO BONE-MINERAL DENSITY
    LIM, TH
    AN, HS
    EVANICH, C
    HASANOGLU, KY
    MCGRADY, L
    WILSON, CR
    JOURNAL OF SPINAL DISORDERS, 1995, 8 (02): : 121 - 125
  • [16] Influence of thread design on bioabsorbable interference screw insertion torque during retrograde fixation of a soft-tissue graft in synthetic bone
    Wozniak, TD
    Kocabey, Y
    Klein, S
    Nyland, J
    Caborn, DNM
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (07): : 815 - 819
  • [17] BIOMECHANICAL ANALYSIS OF BONE-MINERAL DENSITY, INSERTION TECHNIQUE, SCREW TORQUE, AND HOLDING STRENGTH OF ANTERIOR CERVICAL PLATE SCREWS
    RYKEN, TC
    CLAUSEN, JD
    TRAYNELIS, VC
    GOEL, VK
    JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 324 - 329
  • [18] Pullout strength of tibial graft fixation in ACL-replacement with a patellar tendon graft: Interference screw versus staple fixation in human knees
    Gerich, TG
    Cassim, A
    Lattermann, C
    Lobenhoffer, HP
    Tscherne, H
    UNFALLCHIRURG, 1998, 101 (03): : 204 - 208
  • [19] Comparison of failure strength between metallic and absorbable interference screws - Influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference
    Pena, F
    Grontvedt, T
    Brown, GA
    Aune, AK
    Engebretsen, L
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (03): : 329 - 334
  • [20] The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation
    Lee, J. H.
    Lee, J-H.
    Park, J. W.
    Shin, Y. H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (01): : 93 - 97