Real Time Control of Above-Knee Prosthesis with Powered Knee and Ankle Joints

被引:2
|
作者
Jelacic, Zlata [1 ]
Dedic, Remzo [2 ]
机构
[1] Univ Sarajevo, Fac Mech Engn, Vilsonovo Setaliste 9, Sarajevo 71000, Bosnia & Herceg
[2] Univ Mostar, Mostar 88000, Bosnia & Herceg
关键词
Powered above-knee prosthesis; Control unit; Real time control; Prototype testing;
D O I
10.1007/978-3-030-18072-0_33
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Passive prostheses, which are mostly used by amputees, enable performance of various activities such as walking on levelled and inclined ground, and even running, riding a bicycle and as of lately swimming. However, performing high power demanding tasks, such as stair ascent, presents a problem, because the lack of muscles makes it impossible to produce the required forces. To perform high demanding power activities, prosthesis must be powered, primarily in its main joints - knee and ankle. In this paper, we present the real time control of newly developed above-knee prosthetic SmartLeg prototype with powered knee and ankle joints. Specialized control unit is developed in order to achieve required kinematics and dynamics to enable it to perform high power demanding activities in more natural manner, especially stair ascent.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 50 条
  • [31] BIOFEEDBACK TRAINING OF KNEE CONTROL IN ABOVE-KNEE AMPUTEE
    FERNIE, G
    HOLDEN, J
    SOTO, M
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1978, 57 (04) : 161 - 166
  • [32] Can a powered knee-ankle prosthesis improve weight-bearing symmetry during stand-to-sit transitions in individuals with above-knee amputations?
    Hunt, Grace R.
    Hood, Sarah
    Gabert, Lukas
    Lenzi, Tommaso
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2023, 20 (01)
  • [33] An above-knee prosthesis with magnetorheological variable-damping
    Ochoa-Diaz, Claudia
    Rocha, Thiago S.
    Oliveira, Lucas de Levy
    Paredes, Miguel G.
    Lima, Rafael
    Bo, Antonio Padilha L.
    Borges, Geovany A.
    2014 5th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), 2014, : 108 - 113
  • [34] Parametric Design and Hybrid Fabrication of Above-Knee Prosthesis
    Amrutsagar, Lalitrao
    Parit, Gaurav
    Ghyar, Rupesh
    Bhallamudi, Ravi
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (03) : 381 - 390
  • [35] Can a powered knee-ankle prosthesis improve weight-bearing symmetry during stand-to-sit transitions in individuals with above-knee amputations?
    Grace R. Hunt
    Sarah Hood
    Lukas Gabert
    Tommaso Lenzi
    Journal of NeuroEngineering and Rehabilitation, 20
  • [36] Analysis of a novel above-knee prosthesis based on EMG
    Zhang, Min
    Wang, Hong
    Zuo, Koucheng
    2007 IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION, VOLS 1-7, 2007, : 1602 - +
  • [37] Parametric Design and Hybrid Fabrication of Above-Knee Prosthesis
    Lalitrao Amrutsagar
    Gaurav Parit
    Rupesh Ghyar
    Ravi Bhallamudi
    Indian Journal of Orthopaedics, 2020, 54 : 381 - 390
  • [38] A Test-bed for above-knee intelligent prosthesis
    Hao, Lina
    Xu, Xinhe
    Cheng, Jun
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-3, 2006, : 1311 - +
  • [39] A PNEUMATIC ARTIFICIAL MUSCLE ACTUATED ABOVE-KNEE PROSTHESIS
    Waycaster, Garrett
    Wu, Sai-Kit
    Shen, Xiangrong
    PROCEEDINGS OF THE ASME DYNAMIC SYSTEMS AND CONTROL CONFERENCE 2010, VOL 1, 2010, : 793 - 800
  • [40] Modelling and reference tracking of the robotic above-knee prosthetic leg with actuated knee and ankle joints during stair climbing
    Jelacic, Zlata
    Dedic, Remzo
    HEALTH AND TECHNOLOGY, 2020, 10 (01) : 119 - 134