Effect of strut distribution on neointimal coverage of everolimus-eluting bioresorbable scaffolds: an optical coherence tomography study

被引:0
|
作者
Sato, Takao [1 ,2 ]
Jose, John [1 ,3 ]
Allai, Abdelhakim [1 ]
El-Mawardy, Mohamed [1 ]
Toelg, Ralph [1 ]
Richardt, Gert [1 ]
Abdel-Wahab, Mohamed [1 ]
机构
[1] Univ Kiel, Acad Teaching Hosp, Heart Ctr, Segeberger Kliniken GmbH, Kurpk 1, D-23795 Bad Segeberg, Germany
[2] Tachikawa Gen Hosp, Cardiol, Nagaoka, Niigata, Japan
[3] Christian Med Coll & Hosp, Vellore, Tamil Nadu, India
关键词
Neointimal proliferation; Optical coherence tomography; Bioresorbable vascular scaffolds; CORONARY-ARTERY MODEL; STENT IMPLANTATION; INTRAVASCULAR ULTRASOUND; VASCULAR SCAFFOLDS; SHEAR-STRESS; METALLIC STENT; TRIAL; HYPERPLASIA; RESTENOSIS; PREDICTORS;
D O I
10.1007/s11239-017-1511-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The thick struts of bioresorbable vascular scaffolds (BRS) are associated with changes in wall shear stress and contribute to neointimal proliferation. We aimed to evaluate the relationship between the BRS strut distribution and the neointimal proliferation. 50 lesions underwent optical coherence tomography, 12 months after BRS implantation. Scaffold area and neointimal thickness were evaluated in each cross-sectional area (CSA). Scaffold eccentricity was defined as follows: (maximum diameter - minimum diameter) x 100/maximum diameter. CSAs of BRS were divided into four quadrants. The maximal neointimal thickness (Maximal-NIT), Minimal-NIT and the number of struts in each quadrant were measured. The number of struts were classified as 1, 2, 3 and 4. Furthermore, the mean-NIT acquired in each quadrant was divided by the average-NIT of all struts in the same CSA, which was defined as the unevenness score. In addition, Maximal-NIT minus Minimal-NIT was divided by the average-NIT of all struts in the same CSA, which was defined as heterogenicity of neointimal proliferation. There was a significant difference in the association between the number of struts and not only the unevenness score (no. of strut = 1 (N = 440), unevenness score 1.04 +/- 0.34; 2 (N = 696), 0.98 +/- 0.27; 3 (N = 994), 0.96 +/- 0.23; 4 (N = 1202), 1.04 +/- 0.22, P < 0.01) but also Maximal-NIT and Minimal-NIT. Furthermore, a significant correlation was observed between scaffold eccentricity in each CSA and the heterogeneity of neointimal proliferation in the same CSA (N = 892, R = 0.38, p = 0.01). Crowding of struts is associated with increased neointimal proliferation after BRS implantation. The scaffold eccentricity causes heterogeneity of neointimal proliferation.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [21] Serial Optical Coherence Tomography Assessment of the Everolimus-Eluting Absorb™ Bioresorbable Vascular Scaffold: Strut Coverage and Dynamic Malapposition Patterns at 9-month
    Antonsen, Lisbeth
    Thayssen, Per
    Jensen, Lisette Okkels
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B151 - B151
  • [22] Longitudinal Neointimal Distribution Pattern After Everolimus-Eluting Stent Implantation: Insights From Optical Coherence Tomography Study
    Curio, Jonathan
    Hioki, Hirofumi
    Brugaletta, Salvatore
    Gomez-Lara, Josep
    Romaguera, Rafael
    Cequier, Angel
    Herrera, Raul
    Jimenez-Quevedo, Pilar
    Otsuki, Shuji
    Masotti, Monica
    Sabate, Manel
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 26 : 17 - 23
  • [23] Intracoronary Optical Coherence Tomography and Histology of Overlapping Everolimus-Eluting Bioresorbable Vascular Scaffolds in a Porcine Coronary Artery Model
    Farooq, Vasim
    Serruys, Patrick W.
    Heo, Jung Ho
    Gogas, Bill D.
    Onuma, Yoshinobu
    Perkins, Laura E.
    Diletti, Roberto
    Radu, Maria D.
    Raber, Lorenz
    Bourantas, Christos V.
    Zhang, Yaojun
    van Remortel, Eric
    Pawar, Ravindra
    Rapoza, Richard J.
    Powers, Jennifer C.
    van Beusekom, Heleen M. M.
    Garcia-Garca, Hector M.
    Virmani, Renu
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (05) : 523 - 532
  • [24] Assessment of strut coverage of everolimus-eluting platinum chromium stent 2 weeks after implantation by optical coherence tomography
    Oka, Norikiyo
    Fujii, Kenichi
    Kadohira, Tadayuki
    Kitahara, Hideki
    Fujimoto, Yoshihide
    Takahara, Masayuki
    Himi, Toshiharu
    Ishikawa, Keishi
    Sano, Koichi
    Kobayashi, Yoshio
    [J]. HEART AND VESSELS, 2019, 34 (08) : 1258 - 1265
  • [25] Early Coverage of Drug Eluting Stents and Bioresorbable Scaffolds Analysed By Optical Coherence Tomography: Evidence of the Impact of Stent Apposition and Strut Characteristic on the Neointimal Healing Process
    Lee, Renick D.
    Foin, Nicolas
    Soh, Nicole
    Ang, Ivy
    Shim, Winston
    Torii, Ryo
    Wong, Philip
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B180 - B180
  • [26] Neointimal Coverage, Vessel Wall Healing and Major Evaginations after Everolimus-Eluting Absorb™ Bioresorbable Vascular Scaffold implantation Assessed with Serial Optical Coherence Tomography
    Antonsen, Lisbeth
    Thayssen, Per
    Jensen, Lisette Okkels
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B222 - B222
  • [27] Comparison of Early Strut Coverage Between Zotarolimus- and Everolimus-Eluting Stents Using Optical Coherence. Tomography
    Kim, Seunghwan
    Kim, Jung-Sun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Cho, Yun-Kyeong
    Nam, Chang-Wook
    Hur, Seung-Ho
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (01): : 1 - 5
  • [28] Assessment of strut coverage of everolimus-eluting platinum chromium stent 2 weeks after implantation by optical coherence tomography
    Norikiyo Oka
    Kenichi Fujii
    Tadayuki Kadohira
    Hideki Kitahara
    Yoshihide Fujimoto
    Masayuki Takahara
    Toshiharu Himi
    Keishi Ishikawa
    Koichi Sano
    Yoshio Kobayashi
    [J]. Heart and Vessels, 2019, 34 : 1258 - 1265
  • [29] ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT)
    Kim, Jung-Sun
    Kim, Byeong-Kuk
    Jang, Ik-Kyung
    Shin, Dong-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Cho, Yun-Kyeong
    Nam, Chang-Wook
    Hur, Seung-Ho
    Choi, Jin-Ho
    Song, Young Bin
    Hahn, Joo Yong
    Choi, Seung Hyuk
    Gwon, Hyeon Cheol
    Jang, Yangsoo
    [J]. AMERICAN HEART JOURNAL, 2012, 163 (04) : 601 - 607
  • [30] An observational study of clinical outcomes of everolimus-eluting bioresorbable scaffolds comparing the procedural use of optical coherence tomography against angiography alone
    Hamshere, Stephen
    Byrne, Alex
    Guttmann, Oliver
    Rees, Paul
    Bourantas, Christos
    Weerakody, Roshan
    Wragg, Andrew
    Knight, Charles
    Mathur, Anthony
    Jones, Daniel A.
    [J]. CORONARY ARTERY DISEASE, 2018, 29 (06) : 482 - 488