Analysis of Transient Characteristics in the 110kV Cable Joint System during Switch Closing

被引:0
|
作者
Wang, Huanan [1 ]
Wang, Xia [1 ]
Yu, Dong [1 ]
Shu, Zihang [1 ]
Wu, Kai [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
关键词
cable joint; closing angle; cable line length; overvoltage; electric field strength;
D O I
10.1109/icempe.2019.8727350
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, there occur quite a few breakdowns of cable joint when circuit breakers are closed in the 110kV cable lines. It's necessary to pay attention to the influence of cable joint in cable line without load during closing because of the different wave impedance between cable body and joint. In this paper, a RLC equivalent model of cable joint is established, and then an 110kV cable line including 14 joints is simulated by PSCAD. To study the effects of closing angle on overvoltage at cable joint core and metal shielding, the circuit breaker was closed 360 times in one power frequency cycle by using Multiple Run in PSCAD. Additionally, Fast Fourier Transform ( FFT) is used to analyze the frequency characteristic of overvoltage at joint metal shielding. Then to study the effects of cable length on joint overvoltage, three different cable line lengths with the number of joint unchanged are simulated. Then electric field distribution inside the joint which suffered the most serious overvoltage is simulated by ANSYS. The simulation results show that cable line overvoltage is a 180 degrees periodic function of the closing angle. The ideal closing angle and the closing angle matched the most serious overvoltage are both at the intersections of overvoltage curve of the phase B and the phase C. When breaker is closed at 0 degrees, the maximum overvoltage of cable is 1.23p.u. While when breaker is closed at 90 degrees, the maximum overvoltage of cable line is 1.85p.u. In addition, the shielding overvoltage of the 4 straightthrough joints (3#, 6#, 9# and 12#) is more severe than that of other insulated joints. The maximum shielding overvoltage 5.23kV is at 6# joint of phase A with breaker closed at 90 degrees. And FFT analysis of overvoltage at joint metal shielding shows that overvoltage at joint metal shielding contains high-frequency voltage component of 12 kHz to 14 kHz and 4 kHz with their amplitude below 70V. What's more, the line overvoltage increases with the increase of cable length, and the location of maximum overvoltage gradually moves from the end joint to the middle joint with the increase of the cable length when the cable line length is longer than 7500m. What's more, the electric field distribution inside two joints, the 6# joint whose metal shielding suffered the most severe overvoltage in all joints and the 12# joint whose core suffered the most severe overvoltage in all joints, are simulated by ANSYS. The results show that the maximum field strength in the joint 6# and 12# are more than that in joint without overvoltage, and the maximum field strength is always at the root of stress cone. The field strength at interface between silicone rubber and cable insulation in 12# joint is- 1.4kV/mm, and the maximum field strength at the high-voltage shielding tube is 5.7kV/mm, both of which are doubled than those in joint without overvoltage.
引用
收藏
页码:395 / 399
页数:5
相关论文
共 50 条
  • [41] Travelling-Wave-Based On-line Fault Location Scheme for 110kV Power Cable
    Xia Chengjun
    Zhang Hong
    Li Yong
    Jin Bingmei
    2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 632 - 635
  • [42] External Disturbance Detection of 110kV Power Cable based on Built-in Sensing Optical Fiber
    Tian, Haoyuan
    Zhang, Weikai
    Liu, Hong
    Wu, Zhaoguo
    Song, Yuxuan
    Zhang, Zhixian
    Chen, Weigen
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [43] The growth of electrical tree and its PD in inner and outer layer of 110kV XLPE cable insulation
    Wang, Wei
    Sui, Heng
    Yu, YanLong
    Wu, Yankun
    Chen, Guanghui
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [44] Overvoltage of 110kV, 220kV Transformer Neutral Point and Its Protection Analysis
    Li Yining
    Liu Junyi
    Kuang Shi
    Xie Wenbing
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [45] Transient Analysis of the 161-kV Taiwan- PengHu Submarine Power Cable System
    Ho, Ping-Heng
    Wu, Chi-Jui
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2786 - 2793
  • [46] Three-dimensional simulation analysis of electric field distribution at the middle joint of 110 kV cable with typical defects
    Xu, Siqin
    Huang, Xiangqian
    Yang, Song
    Yu, Bin
    Gan, Pengfei
    6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2021, 647
  • [47] Experimental Investigation on the Propagation Characteristics of UHF signals in an Actual 110kV Power Transformer
    Du, Jinchao
    Zhu, Chengzhi
    Chen, Weigen
    Zhang, Zhixian
    Tenbohlen, Stefan
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [48] Study on Leakage Current Characteristics and Influence Factors of 110kV Polluted Composite Insulators
    Liu Zhengfa
    Zhou Qing
    Zhang Wuyang
    Li Shimian
    Wu Gaolin
    Hu Jianlin
    Bi Maoqiang
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 896 - 900
  • [49] Accumulative Insulation Characteristics of 110kV GIS Spacer Under Repeated Impulse Voltages
    Wang, Zengbin
    Lv, Hong
    Wang, Liuhuo
    Chen, Yilong
    Tang, Ying
    Rao, Zhangquan
    Wu, Ji
    Liu, Shupin
    Zhou, Hongyang
    Ma, Guoming
    Zheng, Shusheng
    Li, Chengrong
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 185 - 188