Novel Electrochemical Sensors Based on Cuprous Oxide-Electrochemically Reduced Graphene Oxide Nanocomposites Modified Electrode toward Sensitive Detection of Sunset Yellow

被引:59
|
作者
He, Quanguo [1 ,2 ]
Liu, Jun [1 ,2 ]
Liu, Xiaopeng [2 ]
Xia, Yonghui [3 ]
Li, Guangli [1 ,2 ]
Deng, Peihong [4 ]
Chen, Dongchu [1 ]
机构
[1] Foshan Univ, Sch Mat Sci & Energy Engn, Foshan 528000, Peoples R China
[2] Hunan Univ Technol, Coll Life Sci & Chem, Zhuzhou 412007, Peoples R China
[3] Zhuzhou Inst Food & Drug Control, Zhuzhou 412000, Peoples R China
[4] Hengyang Normal Univ, Dept Chem & Mat Sci, Hengyang 421008, Peoples R China
来源
MOLECULES | 2018年 / 23卷 / 09期
关键词
cuprous oxide nanoparticles; reduced graphene oxide; modified electrode; sunset yellow; second-derivative linear sweep voltammetry; SYNTHETIC FOOD COLORANTS; WALLED CARBON NANOTUBES; TARTRAZINE; DYES; NANOPARTICLES; PHOTOCATALYST; PERFORMANCE; FABRICATION; CU2O;
D O I
10.3390/molecules23092130
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Control and detection of sunset yellow is an utmost demanding issue, due to the presence of potential risks for human health if excessively consumed or added. Herein, cuprous oxide-electrochemically reduced graphene nanocomposite modified glassy carbon electrode (Cu2O-ErGO/GCE) was developed for the determination of sunset yellow. The Cu2O-ErGO/GCE was fabricated by drop-casting Cu2O-GO dispersion on the GCE surface following a potentiostatic reduction of graphene oxide (GO). Scanning electron microscope and X-ray powder diffractometer was used to characterize the morphology and microstructure of the modification materials, such as Cu2O nanoparticles and Cu2O-ErGO nanocomposites. The electrochemical behavior of sunset yellow on the bare GCE, ErGO/GCE, and Cu2O-ErGO/GCE were investigated by cyclic voltammetry and second-derivative linear sweep voltammetry, respectively. The analytical parameters (including pH value, sweep rate, and accumulation parameters) were explored systematically. The results show that the anodic peak currents of Cu2O-ErGO /GCE are 25-fold higher than that of the bare GCE, due to the synergistic enhancement effect between Cu2O nanoparticles and ErGO sheets. Under the optimum detection conditions, the anodic peak currents are well linear to the concentrations of sunset yellow, ranging from 2.0 x 10(-8) mol/L to 2.0 x 10(-5) mol/L and from 2.0 x 10(-5) mol/L to 1.0 x 10(-4) mol/L with a low limit of detection (S/N = 3, 6.0 x 10(-9) mol/L). Moreover, Cu2O-ErGO/GCE was successfully used for the determination of sunset yellow in beverages and food with good recovery. This proposed Cu2O-ErGO/GCE has an attractive prospect applications on the determination of sunset yellow in diverse real samples.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] One-Pot Electrochemical Synthesis of Lead Oxide-Electrochemically Reduced Graphene Oxide Nanostructures and Their Electrocatalytic Applications
    Urhan, Bingul Kurt
    Oznuluer, Tuba
    Demir, Umit
    Dogan, Hulya Ozturk
    IEEE SENSORS JOURNAL, 2019, 19 (13) : 4781 - 4788
  • [22] Electrochemical sensing of phenacetin on electrochemically reduced graphene oxide modified glassy carbon electrode
    Meng, Xiao-Tong
    Zhu, De-Jing
    Jiang, Yu-Hang
    Cao, Yue
    Si, Wei-Meng
    Cao, Jun
    Li, Qiu-Hong
    Li, Jiao
    Lei, Wu
    NEW CARBON MATERIALS, 2022, 37 (04) : 764 - 771
  • [23] A Sensitive Electrochemical Sensor for Tectoridin Detection Based on Reduced Graphene Oxide/Polyethyleneimine Modified Glassy Carbon Electrode
    Wei, Yingliang
    Wang, Anting
    Wang, Lu
    Wang, Fang
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2023, 59 (06) : 473 - 480
  • [24] A Sensitive Electrochemical Sensor for Tectoridin Detection Based on Reduced Graphene Oxide/Polyethyleneimine Modified Glassy Carbon Electrode
    Anting Yingliang Wei
    Lu Wang
    Fang Wang
    Russian Journal of Electrochemistry, 2023, 59 : 473 - 480
  • [25] Graphene electrode modified with electrochemically reduced graphene oxide for label-free DNA detection
    Li, Bing
    Pan, Genhua
    Avent, Neil D.
    Lowry, Roy B.
    Madgett, Tracey E.
    Waines, Paul L.
    BIOSENSORS & BIOELECTRONICS, 2015, 72 : 313 - 319
  • [26] Polydopamine@electrochemically reduced graphene oxide-modified electrode for electrochemical detection of free-chlorine
    Kumar, Deivasigamani Ranjith
    Kesavan, Srinivasan
    Thi Toan Nguyen
    Hwang, Jinho
    Lamiel, Charmaine
    Shim, Jae-Jin
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 818 - 828
  • [27] Electrochemical Sensors for Detection of Glucose based on Electrochemically Reduced Graphene Oxide: Optimization of pH and Number of Cycles
    Ilias, Muhammad Haziq
    Khairuddin, Norhazlin
    Zolkapli, Maizatul
    Zain, Zainiharyati Mohd
    Bakar, Noor Fitrah Abu
    Rani, Rozina Abdul
    Manut, Azrif
    Zoolfakar, Ahmad Sabirin
    INTERNATIONAL JOURNAL OF NANOELECTRONICS AND MATERIALS, 2023, 16 : 241 - 252
  • [28] Electrochemical behavior of palmatine and its sensitive determination based on an electrochemically reduced L-methionine functionalized graphene oxide modified electrode
    WenhuaQiao
    Wang, Lu
    Ye, Baoxian
    Li, Gaiping
    Li, Jianjun
    ANALYST, 2015, 140 (23) : 7974 - 7983
  • [29] Electrochemical sensors for simultaneous detection of dopamine and uric acid based on a composite of electrochemically reduced graphene oxide and PEDOT:PSS-modified glassy carbon electrode
    Ta'alia, Shafa Aini Hasnawati
    Rohaeti, Eti
    Putra, Budi Riza
    Wahyuni, Wulan Tri
    RESULTS IN CHEMISTRY, 2023, 6
  • [30] Simple and Sensitive Voltammetric Determination of Esculetin Using Electrochemically Reduced Graphene Oxide Modified Electrode
    Li, Yinfeng
    Li, Ying
    Li, Kunjing
    Ye, Baoxian
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2015, 62 (07) : 652 - 660