Simultaneous determination of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry on a stannum film electrode

被引:101
|
作者
Zhu, Wei Wei [1 ]
Bing, Nian [1 ]
Luo, Hong Qun [1 ]
机构
[1] Southwest Univ, Sch Chem & Chem Engn, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
stannum film electrode; chromium(III); cadmium(ll); differential pulse anodic stripping voltammetry;
D O I
10.1016/j.talanta.2007.04.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stannum film electrode has been developed for the simultaneous determination of trace levels of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry (DPASV). The stannum film electrode was generated in situ by depositing simultaneously the stannum film and the metals obtained by reduction of Cd(II) and Cr(III) at -1.4 V on a glassy carbon electrode. Then, the reduced products were oxidized by scanning the potential of the electrode from -1.4 to -0.4 V using DPASV. The electrode exhibited well-defined and separated stripping signals for both metals accompanied with a low background contribution. The possible mechanism of this design was proposed. Under the optimized working conditions, the detection limit was 2.0 and 1.1 mu g l(-1) for Cr(III) and Cd(II) at a deposition time of 3 min. Finally, the stannum film electrode was successfully applied to the determination of Cd(II) in tap water with satisfactory results. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1733 / 1737
页数:5
相关论文
共 50 条
  • [21] Simultaneous determination of lead and cadmium in water samples using differential pulse anodic stripping voltammetry at platinum nanoflowers modified glassy electrode
    Lieu, Nguyen Thi
    Hoang, Cao Van
    Le, Pham Thi Tuyet
    Giang, Le Truong
    VIETNAM JOURNAL OF CHEMISTRY, 2019, 57 (03) : 379 - 383
  • [22] DETERMINATION OF TL(I), PB(II) AND CU(II) BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY WITH A THIN MERCURY FILM ELECTRODE
    DIEKER, J
    VANDERLINDEN, WE
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1975, 274 (02): : 97 - 101
  • [23] A Novel Tellurium Film Electrode for Simultaneous Determination of Cd(II) and Pb(II) Using Anodic Stripping Voltammetry
    Jiang, Jie
    Xu, Miao-Qing
    Liu, Jin-Feng
    Zhao, Guang-Chao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (11): : 6572 - 6579
  • [24] Differential Pulse Anodic Stripping Voltammetry Determination of Lead(II) and Cadmium(II) with Multiwalled Carbon Nanotubes-Thiol Functionalized Chitosan Modified Bismuth Film Electrode
    Guo, Yan
    Ma, Yan
    Gao, Guizhi
    Li, Jun
    Xu, Jianqiang
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (01) : 113 - 118
  • [25] DETERMINATION OF ARSENIC BY ANODIC-STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    FORSBERG, G
    OLAUGHLIN, JW
    MEGARGLE, RG
    KOIRTYOHANN, SR
    ANALYTICAL CHEMISTRY, 1975, 47 (09) : 1586 - 1592
  • [26] Simultaneous determination of copper, lead, cadmium and zinc using differential pulse anodic stripping voltammetry in a flow system
    van Staden, JF
    Matoetoe, MC
    ANALYTICA CHIMICA ACTA, 2000, 411 (1-2) : 201 - 207
  • [27] Simultaneous determination of Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry based on graphite nanofibers-Nafion composite modified bismuth film electrode
    Li, Dongyue
    Jia, Jianbo
    Wang, Jianguo
    TALANTA, 2010, 83 (02) : 332 - 336
  • [28] Determination of thallium by differential pulse anodic stripping voltammetry
    Karbowska, Bozena
    Zembrzuski, Wlodzimierz
    Wojtkowiak, Tomasz
    Lukaszewski, Zenon
    PRZEMYSL CHEMICZNY, 2014, 93 (06): : 978 - 982
  • [29] DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR MERCURY DETERMINATION
    Verestiuc, Paul C.
    Tucaliuc, Oana-Maria
    Breaban, Iuliana G.
    Cretescu, Igor
    Nemtoi, Gheorghe
    ACTA CHEMICA IASI, 2015, 23 (01) : 13 - 24
  • [30] Determination of trace arsenic(III) by differential-pulse anodic stripping voltammetry with in-situ plated bismuth-film electrode
    Long, Jiajie
    Nagaosa, Yukio
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (01) : 51 - 60