Simultaneous determination of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry on a stannum film electrode

被引:101
|
作者
Zhu, Wei Wei [1 ]
Bing, Nian [1 ]
Luo, Hong Qun [1 ]
机构
[1] Southwest Univ, Sch Chem & Chem Engn, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
stannum film electrode; chromium(III); cadmium(ll); differential pulse anodic stripping voltammetry;
D O I
10.1016/j.talanta.2007.04.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stannum film electrode has been developed for the simultaneous determination of trace levels of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry (DPASV). The stannum film electrode was generated in situ by depositing simultaneously the stannum film and the metals obtained by reduction of Cd(II) and Cr(III) at -1.4 V on a glassy carbon electrode. Then, the reduced products were oxidized by scanning the potential of the electrode from -1.4 to -0.4 V using DPASV. The electrode exhibited well-defined and separated stripping signals for both metals accompanied with a low background contribution. The possible mechanism of this design was proposed. Under the optimized working conditions, the detection limit was 2.0 and 1.1 mu g l(-1) for Cr(III) and Cd(II) at a deposition time of 3 min. Finally, the stannum film electrode was successfully applied to the determination of Cd(II) in tap water with satisfactory results. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1733 / 1737
页数:5
相关论文
共 50 条
  • [1] A stannum-bismuth composite film electrode for simultaneous determination of zinc(II) and cadmium(II) using differential pulse anodic stripping voltammetry
    Li, Nian Bing
    Zhu, Wei Wei
    Luo, Jun Hua
    Luo, Hong Qun
    ANALYST, 2012, 137 (03) : 614 - 617
  • [2] Simultaneous Determination of Trace Zinc(II) and Cadmium(II) by Differential Pulse Anodic Stripping Voltammetry Using a MWCNTs-NaDBS Modified Stannum Film Electrode
    Tian, Yun Qing
    Li, Nian Bing
    Luo, Hong Qun
    ELECTROANALYSIS, 2009, 21 (23) : 2584 - 2589
  • [3] Anodic Stripping Voltammetry with Pencil Graphite Electrode for Determination of Chromium (III)
    Wyantuti, S.
    Hafidza, R. A.
    Ishmayana, S.
    Hartati, Y. W.
    INTERNATIONAL SEMINAR ON MATHEMATICS, SCIENCE, AND COMPUTER SCIENCE EDUCATION (MSCEIS 2016), 2017, 812
  • [4] DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY OF CADMIUM(II) WITH A ROTATING MEMBRANE-COVERED MERCURY FILM ELECTRODE
    STEWART, EE
    SMART, RB
    ANALYTICAL CHEMISTRY, 1984, 56 (07) : 1131 - 1135
  • [5] DETERMINATION OF ARSENIC BY ANODIC STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY
    OLAUGHLI.JW
    FORSBERG, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1973, (AUG26): : 34 - 34
  • [6] Determination of cadmium in sewage sludge by differential pulse anodic stripping voltammetry
    Pacer, RA
    Ellis, CKS
    Peng, RZ
    TALANTA, 1999, 49 (04) : 725 - 733
  • [7] Simultaneous determination of lead(II) and cadmium(II) at a diacetyldioxime modified carbon paste electrode by differential pulse stripping voltammetry
    Hu, CG
    Wu, KB
    Dai, X
    Hu, SS
    TALANTA, 2003, 60 (01) : 17 - 24
  • [8] Determination of antimony in steel by differential pulse anodic stripping voltammetry at a rotating gold film electrode
    Tanaka, T
    Ishiyama, T
    Okamoto, K
    ANALYTICAL SCIENCES, 2000, 16 (01) : 19 - 23
  • [9] Determination of Antimony in Steel by Differential Pulse Anodic Stripping Voltammetry at a Rotating Gold Film Electrode
    Tatsuhiko Tanaka
    Takashi Ishiyama
    Kumi Okamoto
    Analytical Sciences, 2000, 16 : 19 - 24
  • [10] Barium Hydrogen Phosphate Modified Carbon Paste Electrode for the Simultaneous Determination of Cadmium and Lead by Differential Pulse Anodic Stripping Voltammetry
    Sheela, T.
    Basavanna, S.
    Viswanatha, R.
    Kalachar, H. C. B.
    Naik, Y. Arthoba
    ELECTROANALYSIS, 2011, 23 (05) : 1150 - 1157