Changes in Accommodative and Binocular Function following Phakic Intraocular Lens for High and Low-to-Moderate Myopia

被引:0
|
作者
Lopez-Artero, Esther [1 ]
Poyales, Francisco [1 ]
Garzon, Nuria [1 ,2 ]
Matamoros, Alicia [1 ]
Saez, Alba [1 ]
Zhou, Ying [3 ]
Garcia-Montero, Maria [1 ,2 ]
机构
[1] Miranza Grp, C Galileo 104, Madrid 28003, Spain
[2] Univ Complutense Madrid, Fac Opt & Optometry, Optometry & Vis Dept, Madrid 28037, Spain
[3] OCULUS Iberia SL, Madrid 28760, Spain
关键词
refractive surgery; phakic intraocular lens; implantable collamer lens (ICL); accommodation; binocular vision; high-myopia and low-to-moderate myopia; CONVERGENCE;
D O I
10.3390/ijerph19116716
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim was to evaluate accommodative and binocular function of phakic intraocular lens implantable collamer lens (ICL) in high and low-to-moderate myopia. Prospective comparative cohort study with 38 myopic patients who underwent ICL implantation were divided into two groups of 19 patients, each one based on the spherical equivalent (SE): high-power (SE <= -6 D) and low-to-moderate (SE > -6 D). The push-up amplitude of accommodation (AA), monocular accommodative facility (MAF), distance and near ocular deviation, near convergence amplitude, near point convergence (NPC), stereopsis, and accommodative convergence/accommodation (AC/A) ratio were assessed before surgery and 1 week and 1 month postoperatively. The mean residual refractive error at 1 month after surgery improved in both groups, 0.18 +/- 0.34 D and 0.09 +/- 0.26 D, respectively (p < 0.001). There was a significant decrease in AA in both groups between preoperatively and at 1-week (p = 0.001; p = 0.008, respectively) and 1-month follow-up (p = 0.001; p = 0.008). For the rest of the binocular measurements, no statistically significant postoperative changes were found in any group. This finding suggests follow-up studies on amplitude of accommodation in phakic intraocular lens ICL implantation.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Posterior chamber phakic intraocular lens implantation: comparative, multicentre study in 351 eyes with low-to-moderate or high myopia
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Kitazawa, Yoshihiro
    Kojima, Takashi
    Nakamura, Tomoaki
    Oka, Yoshitaka
    Matsumoto, Rei
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (02) : 177 - 181
  • [2] Ultrasound Biomicroscopy of Anterior Segment Accommodative Changes with Posterior Chamber Phakic Intraocular Lens in High Myopia
    Du, Chixin
    Wang, Jianhua
    Wang, Xiaoyu
    Dong, Ying
    Gu, Yangshun
    Shen, Ye
    OPHTHALMOLOGY, 2012, 119 (01) : 99 - 105
  • [3] Artisan phakic intraocular lens for correcting high myopia
    Lifshitz T.
    Levy J.
    Aizenman I.
    Klemperer I.
    Levinger S.
    International Ophthalmology, 2004, 25 (4) : 233 - 238
  • [4] Iris claw phakic intraocular lens for high myopia
    Menezo, JL
    Avino, JA
    Cisneros, A
    RodriguezSalvador, V
    MartinezCosta, R
    JOURNAL OF REFRACTIVE SURGERY, 1997, 13 (06) : 545 - 555
  • [5] Phakic posterior chamber intraocular lens for high myopia
    Pineda-Fernández, A
    Jaramillo, J
    Vargas, J
    Jaramillo, M
    Jaramillo, J
    Galíndez, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11): : 2277 - 2283
  • [6] Correction of high myopia with the PRL phakic intraocular lens
    Donoso, Rodrigo
    Castillo, Pavel
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08): : 1296 - 1300
  • [7] Posterior chamber collamer phakic intraocular lens implantation: Comparison of efficacy and safety for low and moderate-to-high myopia
    Pinto, Christophe
    Monteiro, Tiago
    Franqueira, Nuno
    Faria-Correia, Fernando
    Mendes, Jose
    Vaz, Fernando
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (02) : 894 - 901
  • [8] Posterior chamber phakic intraocular lens implantation for high myopia
    沈晔
    杜持新
    顾扬顺
    王竞
    Chinese Medical Journal, 2003, (10)
  • [9] Posterior chamber phakic intraocular lens implantation for high myopia
    Shen, Y
    Du, CX
    Gu, YS
    Wang, J
    CHINESE MEDICAL JOURNAL, 2003, 116 (10) : 1523 - 1526
  • [10] Iris-claw phakic intraocular lens for high myopia
    Landesz, M
    van Rij, G
    Luyten, G
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (06) : 634 - 640