Iris claw phakic intraocular lens for high myopia

被引:0
|
作者
Menezo, JL
Avino, JA
Cisneros, A
RodriguezSalvador, V
MartinezCosta, R
机构
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND: The implantation of a Worst-Fechner iris claw intraocular lens (IOL) is one of the surgical procedures used for the correction of high myopia. This technique reduces myopia with stable refractive results; however, its potential long-term risks have not been evaluated. We report results in 94 eyes with a minimum follow-up of 3 years. METHODS: We studied 94 eyes of 62 patients with myopia greater than or equal to -7.00 diopters (D) who underwent Worst-Fechner IOL implantation. Lens decentration, permeability of the blood-aqueous barrier by iris angiography, and changes in corneal endothelial density were analyzed. RESULTS: Mean follow-up time was 48.9 months (range 36 to 72 mo). Three years after surgery, 58 eyes (61%) had an uncorrected visual acuity greater than or equal to 20/40, and 77 eyes (82%) gained two or more lines of spectacle-corrected visual acuity with respect to the preoperative value; 75 eyes (79%) were within +/-1.00 D of emmetropia and 46 eyes (48%) were within +/-0.50 D of emmetropia. The mean endothelial cell loss was 17.9% at 5 years after surgery, while the percentage of hexagonality and the coefficient of cell variation tended toward preoperative levels. No vision threatening complications were seen. CONCLUSIONS: The implantation of a Worst-Fechner iris claw phakic IOL reduced high myopia with a stable refractive outcome. Endothelial cell damage was within acceptable limits. The absence of major complications makes this procedure an acceptable method for correcting high myopia.
引用
收藏
页码:545 / 555
页数:11
相关论文
共 50 条
  • [1] Iris-claw phakic intraocular lens for high myopia
    Landesz, M
    van Rij, G
    Luyten, G
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (06) : 634 - 640
  • [2] Phakic iris claw artisan intraocular lens for correction of high myopia and hyperopia
    Hardten, DR
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) : 209 - 221
  • [3] Ultrasound biomicroscopy of the iris-claw phakic intraocular lens for high myopia
    Pop, M
    Mansour, M
    Payette, Y
    JOURNAL OF REFRACTIVE SURGERY, 1999, 15 (06) : 632 - 635
  • [4] Iris claw phakic intraocular lens
    Dietrich, Marie
    Moussa, Sarah
    Ruckhofer, Josef
    Halbwirth, Esther
    Reitsamer, Herbert
    SPEKTRUM DER AUGENHEILKUNDE, 2019, 33 (06) : 155 - 159
  • [5] Iris claw phakic (Artisan lens) to correct high myopia
    Malecaze, F
    Hulin, H
    Bierer, P
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2000, 23 (09): : 879 - 883
  • [6] Long-term results of correction of high myopia with an iris claw phakic intraocular lens
    Landesz, M
    Worst, JGF
    van Rij, G
    JOURNAL OF REFRACTIVE SURGERY, 2000, 16 (03) : 310 - 316
  • [7] Combined surgery to correct high myopia:: Iris claw phakic intraocular lens and laser in situ keratomileusis
    Güell, JL
    Vazquez, M
    Gris, O
    De Muller, A
    Manero, F
    JOURNAL OF REFRACTIVE SURGERY, 1999, 15 (05) : 529 - 537
  • [8] Outcome of Iris-Claw Phakic Intraocular Lens Implantation for High Myopia; A Subspecialty Training Setting
    Siatiri, Heidar
    Mohammadi, Seyed Farzad
    Nasab, Mercede Majdi
    AbdollahiNia, Tahereh
    Siatiri, Nasim
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2009, 21 (03): : 21 - 28
  • [9] Artisan phakic iris claw intraocular lens for high primary and secondary hyperopia
    Alió, JL
    Mulet, ME
    Shalaby, AMM
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (06) : 697 - 707
  • [10] Giant retinal tear after iris claw phakic intraocular lens
    Hernáez-Ortega, MC
    Soto-Pedre, E
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (06) : 839 - 840