Ultrasound biomicroscopy of the iris-claw phakic intraocular lens for high myopia

被引:0
|
作者
Pop, M [1 ]
Mansour, M [1 ]
Payette, Y [1 ]
机构
[1] Michel Pop Clin, Montreal, PQ H4N 3H5, Canada
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the in situ relative intraocular position of the Ophtec Artisan iris-claw phakic intraocular lens (PIOL) for high myopia using ultrasound biomicroscopy, METHODS: Three PIOLs (13.00, 17.00 and 18.00 D lens powers) were implanted in phakic myopic eyes. Using ultrasound biomicroscopy, echograms were taken in the anterior chamber to measure the preoperative anterior chamber depth, postoperative distance between the PIOL and the corneal endothelium (endothelial-optic distance), and the postoperative distance between the PIOL and the crystalline lens. RESULTS: Preoperative anterior chamber depth ranged hom 3.10 to 3.40 mm and the postoperative endothelial-optic distance measured 2.11 to 2.44 mm, The distance between the crystalline lens and the posterior surface of the! IOL ranged from 0.78 to 0.93 mm, Several echograms revealed the position of the PIOL on the iris. The pigment layer of the iris did not seem to be disturb;ed by the presence of the PIOL, CONCLUSION: The original anterior chamber depths were reduced by 28% to 34% after implantation, The PIOL-crystalline lens distance ranged hom 0.78 to 0.93 mm. This study of 3 eyes revealed that echograms taken by ultrasound biomicroscopy are useful in verifying the intraocular position of the PIOL within the anterior chamber.
引用
收藏
页码:632 / 635
页数:4
相关论文
共 50 条
  • [1] Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation
    Ayong Yu
    [J]. 眼科学报, 2006, (01) : 35 - 39
  • [2] Iris-claw phakic intraocular lens for high myopia
    Landesz, M
    van Rij, G
    Luyten, G
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (06) : 634 - 640
  • [3] Position of myopic iris-claw phakic intraocular lens by Scheimpflug photography and ultrasound biomicroscopy
    A-Y Yu
    Z-D Lin
    X-Q Chen
    X-Y Cai
    Y-Z Liu
    S-K Luo
    [J]. Eye, 2008, 22 : 233 - 239
  • [4] Position of myopic iris-claw phakic intraocular lens by Scheimpflug photography and ultrasound biomicroscopy
    Yu, A-Y
    Lin, Z-D
    Chen, X-Q
    Cai, X-Y
    Liu, Y-Z
    Luo, S-K
    [J]. EYE, 2008, 22 (02) : 233 - 239
  • [5] Iris claw phakic intraocular lens for high myopia
    Menezo, JL
    Avino, JA
    Cisneros, A
    RodriguezSalvador, V
    MartinezCosta, R
    [J]. JOURNAL OF REFRACTIVE SURGERY, 1997, 13 (06) : 545 - 555
  • [6] Outcome of Iris-Claw Phakic Intraocular Lens Implantation for High Myopia; A Subspecialty Training Setting
    Siatiri, Heidar
    Mohammadi, Seyed Farzad
    Nasab, Mercede Majdi
    AbdollahiNia, Tahereh
    Siatiri, Nasim
    [J]. IRANIAN JOURNAL OF OPHTHALMOLOGY, 2009, 21 (03): : 21 - 28
  • [7] Phakic iris claw artisan intraocular lens for correction of high myopia and hyperopia
    Hardten, DR
    [J]. INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) : 209 - 221
  • [8] Late spontaneous dislocation of a silicone iris-claw phakic intraocular lens
    Shen, Carl
    Elbaz, Uri
    Chan, Clara C.
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2014, 49 (04): : E92 - E94
  • [9] Phacoemulsification in phakic iris-claw lens with cataract
    Khokhar, Sudarshan
    Mahabir, Manish
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (11) : 1609 - 1610
  • [10] Refractive lens exchange versus iris-claw Artisan phakic intraocular lens for hyperopia
    Pop, M
    Payette, Y
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (01) : 20 - 24