Photon spectral characteristics of dissimilar 6MV linear accelerators

被引:0
|
作者
Hinson, W. H. [1 ]
Kearns, W. T. [1 ]
deGguzman, A. F. [1 ]
Bourland, J. D. [1 ]
机构
[1] Wake Forest Univ, Baptist Med Ctr, Winston Salem, NC 27109 USA
关键词
D O I
10.1118/1.2761010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine and compare the energy spectra of four 6MV beams, generated from four physically different accelerators. Also, to demonstrate that the spectra of clinical photon beams can be measured as a part of the beam data collection process for input to a 3D treatment planning system. Methods and Materials: The spectra of 6MV beams that are dosimetrically matched were studied to determine if the beam spectra are similarly matched. Each of the four accelerators examined had different physical designs. The four accelerators were two Varian 2100C/Ds (one 6MV/18MV waveguide and one 6MV/10MV waveguide), one Varian 600C with a vertically mounted waveguide and no bending magnet, and one Siemens MD 67/40 with a 6MV/10MV waveguide. All four accelerators had Percent Depth Dose curves for 6MV that were matched. Spectral measurements were performed by narrow beam transmission measurements through pure aluminum along the central axis of the accelerator, made with a graphite Farmer ion chamber with a Lucite buildup cap. Results: Reconstructed spectra show that all four beams have similar energy distributions with only subtle differences, despite the differences in accelerator design. Comparisons of the measured spectra to the spectra found by the auto‐modeling algorithm in a commercial treatment planning system also showed excellent agreement. Plots of the measured spectra are shown. Conclusions: The measured spectra of different 6MV beams are similar, regardless of accelerator design. The measured spectra agree with those derived by the treatment planning system. Thus, beam spectra can be acquired in a clinical setting at the time of commissioning as a part of the routine beam data collection. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2481 / 2481
页数:1
相关论文
共 50 条
  • [21] A method for selecting reference beam model of VMAT plans with three 6MV beam-matched linear accelerators during radiation oncology
    Yi Li
    Wenjing Wu
    Wei Yuan
    Linyan Chai
    Fengwen Tang
    Ruixin He
    Yongkai Lu
    Yuemei Zhang
    Yongkai Lu
    Long Wang
    Mengfei Wang
    Xiaozhi Zhang
    Long Zhang
    Scientific Reports, 13
  • [22] Direct Aperture Optimizations IMRT in ENT Tumors: Conventional 6MV Beam versus 6MV Flattening Filter-Free Beam in an ARTISTE Linear Accelerator
    Heyden, S.
    Kretschmer, M.
    Blechschmidt, A.
    Sabatino, M.
    Dahle, J.
    Feine, D.
    Giro, C.
    Wuerschmidt, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 34 - 34
  • [23] BEAM CHARACTERISTICS OF A 6MV LINEAR-ACCELERATOR WITH A 40X40CM2 TREATMENT FIELD
    KUMAR, P
    LARSEN, R
    MEDICAL PHYSICS, 1982, 9 (04) : 610 - 611
  • [24] Effect of a 1.4 T Magnetic Field On TLDs with a 6MV Medical Linear Accelerator
    Culberson, W.
    Culberson, W.
    Hammer, C.
    Kapsch, R.
    Ankerhold, U.
    MEDICAL PHYSICS, 2018, 45 (06) : E358 - E358
  • [25] Influence of RF Coil Materials On Surface and Buildup Dose From a 6MV Photon Beam
    Ghila, A.
    Fallone, B.
    Rathee, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3321 - 3321
  • [26] Monte Carlo Simulation of XHA600D 6MV Linear Accelerator
    Dai, Y.
    Lin, H.
    Wu, B.
    Cai, J.
    Pei, X.
    Cao, R.
    Chen, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Feasibility Study of Respiratory Gated RapidArc SBRT Using a 6MV FFF Photon Beam
    Dou, K.
    Jacobs, M.
    Laser, B.
    Safaraz, M.
    Rodgers, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3609 - 3610
  • [28] Skin dose estimation from 6MV photon beams for different clinical setup parameters
    Fayaz, Vahid
    Zandi, Hassan
    Tavakol, Asieh
    World Academy of Science, Engineering and Technology, 2011, 56 : 629 - 630
  • [29] Simulation of An In-Line 6MV Linear Accelerator From Electron Gun to Target
    St Aubin, J.
    Steciw, S.
    Fallone, B.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [30] Obtaining 5MV and 8MV energies from 6MV linear accelerator and investigating the advantages of using in IMRT
    Catan, I.
    Canbolat, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S150 - S151