Photon spectral characteristics of dissimilar 6MV linear accelerators

被引:0
|
作者
Hinson, W. H. [1 ]
Kearns, W. T. [1 ]
deGguzman, A. F. [1 ]
Bourland, J. D. [1 ]
机构
[1] Wake Forest Univ, Baptist Med Ctr, Winston Salem, NC 27109 USA
关键词
D O I
10.1118/1.2761010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine and compare the energy spectra of four 6MV beams, generated from four physically different accelerators. Also, to demonstrate that the spectra of clinical photon beams can be measured as a part of the beam data collection process for input to a 3D treatment planning system. Methods and Materials: The spectra of 6MV beams that are dosimetrically matched were studied to determine if the beam spectra are similarly matched. Each of the four accelerators examined had different physical designs. The four accelerators were two Varian 2100C/Ds (one 6MV/18MV waveguide and one 6MV/10MV waveguide), one Varian 600C with a vertically mounted waveguide and no bending magnet, and one Siemens MD 67/40 with a 6MV/10MV waveguide. All four accelerators had Percent Depth Dose curves for 6MV that were matched. Spectral measurements were performed by narrow beam transmission measurements through pure aluminum along the central axis of the accelerator, made with a graphite Farmer ion chamber with a Lucite buildup cap. Results: Reconstructed spectra show that all four beams have similar energy distributions with only subtle differences, despite the differences in accelerator design. Comparisons of the measured spectra to the spectra found by the auto‐modeling algorithm in a commercial treatment planning system also showed excellent agreement. Plots of the measured spectra are shown. Conclusions: The measured spectra of different 6MV beams are similar, regardless of accelerator design. The measured spectra agree with those derived by the treatment planning system. Thus, beam spectra can be acquired in a clinical setting at the time of commissioning as a part of the routine beam data collection. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2481 / 2481
页数:1
相关论文
共 50 条
  • [1] Photon spectral characteristics of dissimilar 6 MV linear accelerators
    Hinson, William H.
    Kearns, William T.
    deGuzman, Allan F.
    Bourland, J. Daniel
    MEDICAL PHYSICS, 2008, 35 (05) : 1698 - 1702
  • [2] MATCHING THE 6-MV PHOTON-BEAM CHARACTERISTICS OF 2 DISSIMILAR LINEAR ACCELERATORS
    MARSHALL, MG
    MEDICAL PHYSICS, 1993, 20 (06) : 1743 - 1746
  • [3] Surface dose for five telecobalt machines, 6MV photon beam from four linear accelerators and a Hi-Art TomoTherapy
    Kinhikar, Rajesh A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (05) : 381 - 384
  • [4] Skyshine photon doses from 6 and 10 MV medical linear accelerators
    de Paiva, Eduardo
    da Rosa, Luiz A. R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 215 - 219
  • [5] Investigation of the RBE of radiation in the penumbra of a 6mv photon beam
    Syme, A.
    Kirkby, C.
    Mirzayans, R.
    MacKenzie, M.
    Field, C.
    Fallone, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S78 - S78
  • [6] Polarity and ion recombination corrections for SemiFlex 3D 31021 IC in 6MV and 6MV FFF photon beams
    Castellet Garcia, M. C.
    Monasor Denia, P.
    Manjon Garcia, C.
    Lopez Tarjuelo, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S921 - S921
  • [7] IMRT treatment of prostate cancer using 6MV photon beam
    Huang, J
    Katz, A
    Haas, J
    Urrutia, T
    Lauritano, J
    MacMelville, W
    MEDICAL PHYSICS, 2002, 29 (06) : 1254 - 1254
  • [8] Surface Dose and Build-Up Dose Comparison of 6MV and 10MV Flattened with 6MV FFF and 10MV FFF Photon Beams with Different Detectors
    Nambiraj, Arunai
    Sigamani, Ashokkumar
    Kaviarasu, K.
    Rajesh, T.
    Karthikeyan, S.
    Subramanian, Narayanan
    Meerza, Kazem
    MEDICAL PHYSICS, 2015, 42 (06) : 3502 - 3502
  • [9] Comparison of 6MV Photon Dose in a Perpendicular and Parallel Magnetic Field
    Ghila, A.
    Fallone, B.
    Rathee, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 163 - 163
  • [10] Variations in 6MV Photon Energy Spectra Impact the Response of TLD
    Scarboro, S.
    Kry, S.
    Howell, R.
    Followill, D.
    MEDICAL PHYSICS, 2010, 37 (06)