Feasibility of Non-invasive Measurement of Tumour NAD(H) by In Vivo Phosphorus-31 Magnetic Resonance Spectroscopy

被引:0
|
作者
Nath, Kavindra [1 ,2 ]
Arias-Mendoza, Fernando [1 ,2 ]
Xu, He N. [1 ,2 ]
Gupta, Pradeep K. [1 ,2 ]
Li, Lin Z. [1 ,2 ]
机构
[1] Univ Penn, Perelman Sch Med, Dept Radiol, Britton Chance Lab Redox Imaging, Philadelphia, PA USA
[2] Univ Penn, Perelman Sch Med, Dept Radiol, Lab Mol Imaging, Philadelphia, PA USA
来源
关键词
Optical redox ratio; xenograft of MAD-MB-231 breast cancer cell line; xenografts of MCF-7 and BT474 breast cancer cell line; Solution phantoms; INTRACELLULAR PH; REDOX STATE; XENOGRAFTS; MRS;
D O I
10.1007/978-3-031-14190-4_39
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Importance of the redox status of nicotinamide adenine dinucleotide (NAD), including its oxidized (NAD(+)) and reduced (NADH) forms, has been shown in many biological processes. However, NAD(H) redox status assessment is traditionally limited to biochemical assays in vitro or optical redox imaging (ORI) for superficial tissues in vivo and for deep tissues ex vivo. In recent years, phosphorous-31 magnetic resonance spectroscopy (P-31-MRS) was utilized to quantify NAD(+), NADH, and the redox ratio NAD(+)/NADH in normal tissues in vivo. The quantification is based on the spectral fitting of the upfield shoulder of the alpha ATP peak that contains signals of NAD(+) (a quartet) and NADH (a singlet), assuming pH-independence of peak positions. To evaluate the feasibility of measuring tumour NAD(H) redox status in vivo, we fitted single voxel 31P-MR spectra of subcutaneous mouse xenografts of human breast cancer cell lines acquired on a 9.4-T horizontal bore preclinical MR scanner. We found larger variations in the chemical shift offsets of NAD(+) and NADH from alpha ATP in these tumours than the literature values of normal tissues. Furthermore, our P-31-MR spectra of alpha ATP, NAD(+), and NADH solution phantoms indicated that the chemical shift of alpha ATP and thus the offsets between NAD(H) and alpha ATP were pH dependent. Therefore, whether tumour pH should be incorporated into the spectral fitting model should be further evaluated. Additionally, spectral resolution and signal-to-noise ratio should be improved by optimising P-31-MRS protocols, increasing data acquisition time, and using a more sensitive coil for signal detection.
引用
下载
收藏
页码:237 / 242
页数:6
相关论文
共 50 条
  • [31] Non-invasive measurement of human brain temperature using magnetic resonance spectroscopy
    Yoshioka, Y.
    Oikawa, H.
    Kanbara, Y.
    Matsumura, Y.
    Ehara, S.
    Inoue, T.
    Ogawa, A.
    BIORHEOLOGY, 2008, 45 (1-2) : 101 - 102
  • [32] PHOSPHORUS-31 NUCLEAR MAGNETIC-RESONANCE SPECTROSCOPY OF EXTRACELLULAR, YEAST O-PHOSPHONOHEXOGLYCANS
    COSTELLO, AJR
    GLONEK, T
    SLODKI, ME
    SEYMOUR, FR
    CARBOHYDRATE RESEARCH, 1975, 42 (01) : 23 - 37
  • [33] PHOSPHORUS-31 MAGNETIC-RESONANCE SPECTROSCOPY FOR QUANTITATIVE-EVALUATION OF THERAPEUTIC REGIMENS IN DERMATOMYOSITIS
    KING, LE
    PARK, JH
    ADAMS, LB
    OLSEN, NJ
    ARCHIVES OF DERMATOLOGY, 1995, 131 (05) : 522 - 524
  • [34] Utility of hepatic phosphorus-31 magnetic resonance spectroscopy in a rat model of acute liver failure
    Corbin, IR
    Buist, R
    Peeling, J
    Zhang, M
    Uhanova, J
    Minuk, GY
    JOURNAL OF INVESTIGATIVE MEDICINE, 2003, 51 (01) : 42 - 49
  • [35] Assessment of pretransplantation warm ischemia time by phosphorus-31 magnetic resonance spectroscopy in pig kidneys
    Cadrobbi, R
    Rigotti, P
    Baldan, N
    Toffano, M
    Corazza, A
    Scarpa, M
    Rigo, A
    Ancona, E
    TRANSPLANTATION PROCEEDINGS, 1997, 29 (08) : 3415 - 3416
  • [36] Identification of organic phosphorus compounds in the Bronx River bed sediments by phosphorus-31 nuclear magnetic resonance spectroscopy
    Wang, Jingyu
    Pant, Hari K.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 171 (1-4) : 309 - 319
  • [37] Phosphorus-31 Nuclear Magnetic Resonance Spectroscopy Transect Study of Poultry Operations on the Delmarva Peninsula
    Hill, Jane E.
    Cade-Menun, Barbara J.
    JOURNAL OF ENVIRONMENTAL QUALITY, 2009, 38 (01) : 130 - 138
  • [38] In vivo and in vitro hepatic phosphorus-31 magnetic resonance spectroscopy and electron microscopy in chronic ductopenic rejection of human liver allografts
    Taylor-Robinson, SD
    Sargentoni, J
    Bell, JD
    Thomas, EL
    Marcus, CD
    Changani, KK
    Saeed, N
    Hodgson, HJF
    Davidson, BR
    Burroughs, AK
    Rolles, K
    Foster, CS
    Cox, IJ
    GUT, 1998, 42 (05) : 735 - 743
  • [39] Reduced metabolic efficiency of skeletal muscle energetics in hyperthyroid patients evidenced quantitatively by in vivo phosphorus-31 magnetic resonance spectroscopy
    Erkintalo, M
    Bendahan, D
    Mattéi, JP
    Fabrguettes, C
    Vague, P
    Cozzone, PJ
    METABOLISM-CLINICAL AND EXPERIMENTAL, 1998, 47 (07): : 769 - 776
  • [40] Identification of organic phosphorus compounds in the Bronx River bed sediments by phosphorus-31 nuclear magnetic resonance spectroscopy
    Jingyu Wang
    Hari K. Pant
    Environmental Monitoring and Assessment, 2010, 171 : 309 - 319