Quantification of lorazepam and lormetazepam in human breast milk using GC-MS in the negative chemical ionization mode

被引:8
|
作者
Lemmer, Patrick
Schneider, Serge
Muehe, Annette
Wennig, Robert
机构
[1] Univ Luxembourg, Div Toxicol, Lab Natl Sante, L-1511 Luxembourg, Luxembourg
[2] Ctr Hosp Luxembourg, Serv Psychiat Adult, L-1210 Luxembourg, Luxembourg
[3] Ctr Hosp Luxembourg, Serv Psychiat Enfant, L-1210 Luxembourg, Luxembourg
关键词
D O I
10.1093/jat/31.4.224
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lormetazepam (Loramet®) is a benzodiazepine mainly used as an hypnotic to treat insomnia. Lorazepam (Temesta®) is used as an anxiolytic, tranquilizer, sedative, and anticonvulsant, and it is the major metabolite of lormetazepam. In this study, we designed a method to simultaneously detect and quantify these substances in human breast milk. Solid-phase extraction of 2 mL of milk was followed by derivatization with a trimethylsilyl reagent. Separation and detection was performed using gas chromatography coupled to mass spectrometry in the negative chemical ionization mode. Calibration curves were linear in the ranges of 10-200 and 1-20 ng/mL for lorazepam and lormetazepam, respectively. Limits of detection were estimated at 0.016 ng/mL for lormetazepam and 0.100 ng/mL for lorazepam. Our method was applied to real case samples from a woman receiving both benzodiazepines. Lorazepam concentrations varied from 55.3 to 123.1 ng/mL, and lormetazepam concentrations varied from 1.7 to 7.3 ng/mL.
引用
收藏
页码:224 / 226
页数:3
相关论文
共 50 条
  • [21] Automated Solid-Phase Microextraction and Negative Chemical Ionization GC-MS for the Measurement of Synthetic Pyrethroids
    Koch, Del
    Clark, Kevin L.
    Owen, John
    Chickering, Clark D.
    Plastridge, Robert
    Hendley, Paul
    Xu, Tianbo
    CHEMICAL RESEARCH IN TOXICOLOGY, 2021, 34 (09) : 2045 - 2053
  • [22] DETERMINATION OF HYDROXYCARBAMATES IN AQUEOUS MATRICES BY DIRECT DERIVATIZATION AND GC-MS ANALYSIS IN CHEMICAL-IONIZATION MODE
    VINCENTI, M
    MINERO, C
    LAGO, S
    ROVIDA, C
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (06): : 359 - 362
  • [23] Detection of 20 phthalate esters in breast milk by GC-MS/MS using QuEChERS extraction method
    Fan, Ji-Cai
    Ren, Ren
    Jin, Quan
    He, Hua-Li
    Wang, Shu-Ting
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2019, 36 (10): : 1551 - 1558
  • [24] GC-MS CHEMICAL IONIZATION ASSAY FOR HALOPERIDOL WITH SELECTED ION MONITORING
    HORNBECK, CL
    GRIFFITHS, JC
    FAULKNER, MA
    NABORSKY, RJ
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1089 - 1089
  • [25] Chemical ionization and MS-MS technologies for benchtop ion trap GC-MS systems
    Brittain, Robert
    Feigel, Carl
    American Laboratory, 1994, 26 (03)
  • [26] GC-MS/MS quantification of benzyl salicylate on skin and hair: A novel chemical simulant for human decontamination studies
    James, Thomas
    Collins, Samuel
    Amlot, Richard
    Marczylo, Tim
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1129
  • [27] GC-MS Method for Quantification of Mephedrone in Human Blood Sample
    Mohamed, Khaled M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (08) : 784 - 789
  • [28] A selective method for quantification of diazinon in human plasma by GC-MS
    Birich, Bouchra
    El Hajjaji, Souad
    Daoud, Naima Ait
    Bencheikh, Rachida Soulaymani
    Ghandi, Mohammed
    Badrane, Narjis
    ANNALES DE BIOLOGIE CLINIQUE, 2020, 78 (06) : 617 - 622
  • [29] DETERMINATION OF VOLATILE POLLUTANTS IN HUMAN AND ANIMAL MILK BY GC-MS
    KRONELD, R
    REUNANEN, M
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1990, 44 (06) : 917 - 923
  • [30] GC-MS and QuEChERS as an Analytical Tool for the Determination of Impurities in Breast Milk
    Pajewska, Martyna
    Gadzala-Kopciuch, Renata
    Buszewski, Boguslaw
    PROCEEDINGS OF THE 13TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2017, : 65 - 68