Exercise echocardiography versus exercise electrocardiography in the diagnosis of coronary artery disease in hypertension

被引:16
|
作者
Maltagliati, A [1 ]
Berti, M [1 ]
Muratori, M [1 ]
Tamborini, G [1 ]
Zavalloni, D [1 ]
Berna, G [1 ]
Pepi, M [1 ]
机构
[1] Univ Milan, Ist Cardiol, Fdn I Monzino, IRCCS,Ctr Studio Ric Cardiovasc,CNR, I-20138 Milan, Italy
关键词
hypertension; exercise echocardiography; nifedipine;
D O I
10.1016/S0895-7061(00)00247-8
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In hypertension, coronary artery disease (CAD) can be overestimated by stress electrocardiography (ECG) and scintigraphy due to frequent false-positive results. Exercise tests are also limited by an excessive blood pressure increase, and pharmacologic pressure normalization decreases the accuracy of the test. The aim of this study was to assess the accuracy of exercise echocardiography as an alternative test for CAD detection in hypertension, both before and after adequate blood pressure control. We studied 59 hypertensive and 59 normotensive patients undergoing coronary angiography for chest pain. Upright bicycle exercise ECG and echocardiographic tests were performed in each group in the absence of therapy; in hypertensives, the tests were repeated a day apart after blood pressure normalization with sublingual nifedipine. Significant CAD (lumen narrowing >50%) was detected in 22 hypertensive and 41 normotensive patients. In the two groups, sensitivity, specificity, and diagnostic accuracy treatment were not statistically different (95%, 94%, 94% in hypertensives and 82%, 77%, 83% in normotensives, respectively), but were significantly higher than for the exercise ECG test (68%, 70%, and 69%, respectively). After blood pressure lowering, exercise echocardiography sensitivity slightly decreased (91%), whereas specificity (100%) and diagnostic accuracy (96%) did not vary; on the contrary, exercise ECG sensitivity decreased to 45%. Therefore, according to our data, exercise echocardiography can be an accurate test and more reliable than exercise ECG to detect CAD in normotensives as well as in hypertensives. Normalization of blood pressure with nifedipine does not affect its accuracy, but markedly reduces the sensitivity of exercise EGG. (C) 2000 American Journal of Hypertension, Ltd.
引用
收藏
页码:796 / 801
页数:6
相关论文
共 50 条
  • [41] Exercise electrocardiography for pre-test assessment of the likelihood of coronary artery disease
    Rasmussen, Laust Dupont
    Schmidt, Samuel Emil
    Knuuti, Juhani
    Newby, David E.
    Singh, Trisha
    Nieman, Koen
    Galema, Tjebbe W.
    Vrints, Christiaan
    Bottcher, Morten
    Winther, Simon
    HEART, 2024, 110 (04) : 263 - 270
  • [42] ROLE OF EXERCISE ELECTROCARDIOGRAPHY IN RISK STRATIFICATION OF CORONARY-ARTERY DISEASE IN THE ELDERLY
    ARORA, RR
    TEICHHOLZ, LE
    BUTLER, RN
    LIBOW, LN
    HOROWITZ, SF
    CIRCULATION, 1986, 74 (04) : 504 - 504
  • [43] COMPARATIVE ACCURACY OF MAXIMAL TREADMILL AND 2-STEP EXERCISE ELECTROCARDIOGRAPHY IN DIAGNOSIS OF CORONARY-ARTERY DISEASE
    AMSTERDAM, EA
    DEMARIA, A
    DASILVA, O
    WOOD, M
    BROCCHINI, R
    RENDIG, S
    MASON, DT
    CLINICAL RESEARCH, 1976, 24 (02): : A79 - A79
  • [44] Electrocardiography versus Echocardiography in Severe Aortic Stenosis with the Consideration of Coexistent Coronary Artery Disease
    Chyrchel, Michal
    Silka, Wojciech
    Wylaz, Mateusz
    Wojcik, Wiktor
    Surdacki, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [45] SUPINE EXERCISE ELECTROCARDIOGRAPHY COMPARED WITH EXERCISE RADIONUCLIDE ANGIOGRAPHY IN NONINVASIVE IDENTIFICATION OF SEVERE CORONARY-ARTERY DISEASE
    GIBBONS, RJ
    ZINSMEISTER, AR
    MILLER, TD
    CLEMENTS, IP
    ANNALS OF INTERNAL MEDICINE, 1990, 112 (10) : 743 - 749
  • [46] COMPARISON OF DOBUTAMINE AND EXERCISE ECHOCARDIOGRAPHY FOR DETECTING CORONARY-ARTERY DISEASE
    COHEN, JL
    OTTENWELLER, JE
    GEORGE, AK
    DUVVURI, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (17): : 1226 - 1231
  • [47] First-line evaluation of coronary artery disease with coronary calcium scanning or exercise electrocardiography
    Dedic, Admir
    Rossi, A.
    ten Kate, G. J. R.
    Neefjes, L. A.
    Galema, T. W.
    Moelker, A.
    van Domburg, R. T.
    Schultz, C. J.
    Mollet, N. R.
    de Feyter, P. J.
    Nieman, K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 (02) : 190 - 195
  • [48] Dipyridamole-atropine stress echocardiography versus exercise SPECT scintigraphy for detection of coronary artery disease in hypertensives with positive exercise test
    Astarita, A
    Palinkas, A
    Nicolai, E
    Maresca, FS
    Picano, E
    EUROPEAN HEART JOURNAL, 2000, 21 : 618 - 618
  • [49] Incremental prognostic value of exercise imaging over exercise electrocardiography in patients with suspected coronary disease and an intermediate pretest probability of coronary artery disease
    Morise, AP
    CIRCULATION, 2003, 108 (17) : 566 - 566
  • [50] Dipyridamole-atropine stress echocardiography versus exercise SPECT scintigraphy for detection of coronary artery disease in hypertensives with positive exercise test
    Astarita, C
    Pálinkás, A
    Nicolai, E
    Maresca, FS
    Varga, A
    Picano, E
    JOURNAL OF HYPERTENSION, 2001, 19 (03) : 495 - 502