Albumin-binding MR blood pool agents as MRI contrast agents in an intracranial mouse glioma model

被引:26
|
作者
Adzamli, K
Yablonskiy, DA
Chicoine, MR
Won, EK
Galen, KP
Zahner, MC
Woolsey, TA
Ackerman, JJH
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Mallinckrodt Inc, Imaging Div, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Neurosurg, St Louis, MO USA
[4] Barnes Jewish Hosp, St Louis, MO 63110 USA
[5] Univ Washington, Sch Med, Dept Internal Med, St Louis, MO 63110 USA
[6] Univ Washington, Sch Med, Siteman Canc Ctr, St Louis, MO 63110 USA
[7] Univ Washington, Dept Chem Arts & Sci, St Louis, MO USA
关键词
MR contrast media; blood pool agent; brain tumor; mouse glioma model; MRI;
D O I
10.1002/mrm.10382
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intravenous MRI contrast agents are commonly used to improve the detection of intracranial tumors and other central nervous system (CNS) lesions for diagnosis and treatment planning. Two small-molecule, albumin-binding blood pool contrast agents (MP-2269 and MS-325) of potential clinical significance were evaluated at 1.5 Tesla in a mouse glioma model and compared with an extracellular contrast agent (OptiMARK). Tumor image contrast was significantly enhanced and long-lived following administration of 30 mumole/kg of the blood pool agents: specifically, contrast enhancement peaked slowly at 25-30 min following administration, remained constant for >3 hr, and returned to baseline within 20 hr. Comparable but "transient" enhancement was achieved using 100 mumole/kg OptiMARK: specifically, contrast enhancement peaked rapidly at 2-5 min following administration and then declined over 40 min. The blood pool contrast agents demonstrated an approximately threefold increased dose-effectiveness and a lengthened window of tumor contrast enhancement in comparison to commonly available extracellular contrast agents. This demonstrates the potential of alternative contrast-enhanced (CE) MRI examination protocols for tumor detection. (C) 2003 Wiley-Liss, Inc.
引用
下载
收藏
页码:586 / 590
页数:5
相关论文
共 50 条
  • [21] Binding of MRI contrast agents to albumin: a high-field EPR study
    Smirnova, T. I.
    APPLIED MAGNETIC RESONANCE, 2007, 31 (3-4) : 431 - 446
  • [22] Microwave-assisted synthesis of magnetite nanoparticles for MR blood pool contrast agents
    Xiao, Wangchuan
    Gu, Hongchen
    Li, Dan
    Chen, Dandan
    Deng, Xiaoyong
    Jiao, Zheng
    Lin, Jiang
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2012, 324 (04) : 488 - 494
  • [23] An Albumin-Binding T1-T2 Dual-Modal MRI Contrast Agents for Improved Sensitivity and Accuracy in Tumor Imaging
    Zhou, Zijian
    Bai, Ruiliang
    Wang, Zhantong
    Bryant, Henry
    Lang, Lixin
    Merkle, Hellmut
    Munasinghe, Jeeva
    Tang, Longguang
    Tang, Wei
    Tian, Rui
    Yu, Guocan
    Ma, Ying
    Niu, Gang
    Gao, Jinhao
    Chen, Xiaoyuan
    BIOCONJUGATE CHEMISTRY, 2019, 30 (06) : 1821 - 1829
  • [24] SUPERPARAMAGNETIC NANOPARTICLES AS BLOOD-POOL CONTRAST AGENTS - CONTRIBUTION TO MRI PRECLINICAL INVESTIGATIONS
    BENDERBOUS, S
    BONNEMAIN, B
    RADIOLOGE, 1995, 35 (11): : S248 - S252
  • [25] Redox-sensitive contrast agents for MRI based on reversible binding of thiols to serum albumin
    Raghunand, N
    Jagadish, B
    Trouard, TP
    Galons, JP
    Gillies, RJ
    Mash, EA
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1272 - 1280
  • [26] Comprehensive investigation of the non-covalent binding of MRI contrast agents with human serum albumin
    Virginie Henrotte
    Luce Vander Elst
    Sophie Laurent
    Robert N. Muller
    JBIC Journal of Biological Inorganic Chemistry, 2007, 12 : 929 - 937
  • [27] Comprehensive investigation of the non-covalent binding of MRI contrast agents with human serum albumin
    Henrotte, Virginie
    Vander Elst, Luce
    Laurent, Sophie
    Muller, Robert N.
    JOURNAL OF BIOLOGICAL INORGANIC CHEMISTRY, 2007, 12 (06): : 929 - 937
  • [28] Intravascular contrast agents in diagnostic applications: Use of red blood cells to improve the lifespan and efficacy of blood pool contrast agents
    Antonelli, Antonella
    Sfara, Carla
    Magnani, Mauro
    NANO RESEARCH, 2017, 10 (03) : 731 - 766
  • [29] Intravascular contrast agents in diagnostic applications: Use of red blood cells to improve the lifespan and efficacy of blood pool contrast agents
    Antonella Antonelli
    Carla Sfara
    Mauro Magnani
    Nano Research, 2017, 10 : 731 - 766
  • [30] Blood pool contrast agents for venous magnetic resonance imaging
    Oliveira, Irai S.
    Hedgire, Sandeep S.
    Li, Weier
    Ganguli, Suvranu
    Prabhakar, Anand M.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2016, 6 (06) : 508 - 518