Enabling Complex Fibre Geometries Using 3D Printed Axon-Mimetic Phantoms

被引:1
|
作者
Kuehn, Tristan K. [1 ,2 ]
Mushtaha, Farah N. [2 ]
Khan, Ali R. [1 ,2 ,3 ,4 ,5 ]
Baron, Corey A. [1 ,2 ,4 ,5 ]
机构
[1] Western Univ, Robarts Res Inst, Ctr Funct & Metab Mapping, London, ON, Canada
[2] Western Univ, Sch Biomed Engn, London, ON, Canada
[3] Western Univ, Dept Biol, London, ON, Canada
[4] Western Univ, Robarts Res Inst, London, ON, Canada
[5] Western Univ, Schulich Sch Med & Dent, Dept Med Biophys, London, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
diffusion MRI; phantoms; modelling; 3D printing; representations; white matter; axons; GAUSSIAN WATER DIFFUSION; ORIENTATION DISPERSION; MRI;
D O I
10.3389/fnins.2022.833209
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeTo introduce a method to create 3D-printed axon-mimetic phantoms with complex fibre orientations to characterise the performance of diffusion magnetic resonance imaging (MRI) models and representations in the presence of orientation dispersion. MethodsAn extension to an open-source 3D printing package was created to produce a set of five 3D-printed axon-mimetic (3AM) phantoms with various combinations of bending and crossing fibre orientations. A two-shell diffusion MRI scan of the five phantoms in water was performed at 9.4T. Diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), the ball and stick model, neurite orientation density and dispersion imaging (NODDI), and Bingham-NODDI were all fit to the resulting diffusion MRI data. A ground truth map of that phantom's crossing angles and/or arc radius was registered to the diffusion-weighted images. Metrics from each model and representation were compared to the ground-truth maps, and a quadratic regression model was fit to each combination of output metric and ground-truth metric. ResultsThe mean diffusivity (MD) metric defined by DTI was insensitive to crossing angle but increased with fibre curvature. Axial diffusivity (AD) decreased with increasing crossing angle. DKI's diffusivity metrics replicated the trends seen in DTI, and its mean kurtosis (MK) metric decreased with fibre curvature, except in regions with high crossing angles. The estimated stick volume fraction in the ball and stick model decreased with increasing fibre curvature and crossing angle. NODDI's intra-neurite volume fraction was insensitive to crossing angle, and its orientation dispersion index (ODI) was correlated to crossing angle. Bingham-NODDI's intra-neurite volume fraction was also insensitive to crossing angle, while its primary ODI (ODIP) was also correlated to crossing angle and its secondary ODI (ODIS) was insensitive to crossing angle. For both NODDI models, the volume fractions of the extra-neurite and CSF compartments had low reliability with no clear relationship to crossing angle. ConclusionInexpensive 3D-printed axon-mimetic phantoms can be used to investigate the effect of fibre curvature and crossings on diffusion MRI representations and models of diffusion signal. The dependence of several representations and models on fibre dispersion/crossing was investigated. As expected, Bingham-NODDI was best able to characterise planar fibre dispersion in the phantoms.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] 3D Printed Biomimetic Vascular Phantoms for Assessment of Hyperspectral Imaging Systems
    Wang, Jianting
    Ghassemi, Pejhman
    Melchiorri, Anthony
    Ramella-Roman, Jessica
    Mathews, Scott A.
    Coburn, James
    Sorg, Brian
    Chen, Yu
    Pfefer, Joshua
    DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE VII, 2015, 9325
  • [42] 3D printed non-uniform anthropomorphic phantoms for quantitative SPECT
    Lovisa Jessen
    Johan Gustafsson
    Michael Ljungberg
    Selma Curkic-Kapidzic
    Muris Imsirovic
    Katarina Sjögreen-Gleisner
    EJNMMI Physics, 11
  • [43] 3D Printed Radioactive Phantoms for the Validation of Texture Features in PET Radiomics
    Zounek, A.
    Lindheimer, F.
    Zatcepin, A.
    Palumbo, G.
    Gildehaus, F. J.
    Bollenbacher, A.
    Bartenstein, P.
    Albert, N. L.
    Ziegler, S.
    Kaiser, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S762 - S763
  • [44] Multigrid calculation of fluid flows in complex 3D geometries using curvilinear grids
    Univ of British Columbia, Vancouver, Canada
    Comput Fluids, 4 (395-419):
  • [45] Multigrid calculation of fluid flows in complex 3D geometries using curvilinear grids
    He, P
    Salcudean, M
    Gartshore, IS
    Nowak, P
    COMPUTERS & FLUIDS, 1996, 25 (04) : 395 - 419
  • [46] Fabrication of 3D printed complex concentrated alloys using oxide precursors
    Koube, K. D.
    Sloop, T.
    Stiers, C. D.
    Sim, H.
    Kacher, J.
    ADDITIVE MANUFACTURING LETTERS, 2021, 1
  • [47] Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry
    Andrew P. Robinson
    Jill Tipping
    David M. Cullen
    David Hamilton
    Richard Brown
    Alex Flynn
    Christopher Oldfield
    Emma Page
    Emlyn Price
    Andrew Smith
    Richard Snee
    EJNMMI Physics, 3
  • [48] Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry
    Robinson, Andrew P.
    Tipping, Jill
    Cullen, David M.
    Hamilton, David
    Brown, Richard
    Flynn, Alex
    Oldfield, Christopher
    Page, Emma
    Price, Emlyn
    Smith, Andrew
    Snee, Richard
    EJNMMI PHYSICS, 2016, 3 (01): : 1 - 11
  • [49] A simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies
    Nagesh, S. V. Setlur
    Hinaman, J.
    Sommer, K.
    Xiong, Z.
    Ionita, C. N.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL IMAGING 2018: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2018, 10578
  • [50] Novel repair of bolted composite joints using 3D printed continuous fibre patches with custom fibre paths
    Li, Aonan
    Lyu, Yahui
    Yang, Bin
    Yang, Dongmin
    COMPOSITES PART B-ENGINEERING, 2025, 295