PurposeTo introduce a method to create 3D-printed axon-mimetic phantoms with complex fibre orientations to characterise the performance of diffusion magnetic resonance imaging (MRI) models and representations in the presence of orientation dispersion. MethodsAn extension to an open-source 3D printing package was created to produce a set of five 3D-printed axon-mimetic (3AM) phantoms with various combinations of bending and crossing fibre orientations. A two-shell diffusion MRI scan of the five phantoms in water was performed at 9.4T. Diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), the ball and stick model, neurite orientation density and dispersion imaging (NODDI), and Bingham-NODDI were all fit to the resulting diffusion MRI data. A ground truth map of that phantom's crossing angles and/or arc radius was registered to the diffusion-weighted images. Metrics from each model and representation were compared to the ground-truth maps, and a quadratic regression model was fit to each combination of output metric and ground-truth metric. ResultsThe mean diffusivity (MD) metric defined by DTI was insensitive to crossing angle but increased with fibre curvature. Axial diffusivity (AD) decreased with increasing crossing angle. DKI's diffusivity metrics replicated the trends seen in DTI, and its mean kurtosis (MK) metric decreased with fibre curvature, except in regions with high crossing angles. The estimated stick volume fraction in the ball and stick model decreased with increasing fibre curvature and crossing angle. NODDI's intra-neurite volume fraction was insensitive to crossing angle, and its orientation dispersion index (ODI) was correlated to crossing angle. Bingham-NODDI's intra-neurite volume fraction was also insensitive to crossing angle, while its primary ODI (ODIP) was also correlated to crossing angle and its secondary ODI (ODIS) was insensitive to crossing angle. For both NODDI models, the volume fractions of the extra-neurite and CSF compartments had low reliability with no clear relationship to crossing angle. ConclusionInexpensive 3D-printed axon-mimetic phantoms can be used to investigate the effect of fibre curvature and crossings on diffusion MRI representations and models of diffusion signal. The dependence of several representations and models on fibre dispersion/crossing was investigated. As expected, Bingham-NODDI was best able to characterise planar fibre dispersion in the phantoms.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Design and characterization of a 3D-printed axon-mimetic phantom for diffusion MRI
    Mushtaha, Farah N.
    Kuehn, Tristan K.
    El-Deeb, Omar
    Rohani, Seyed A.
    Helpard, Luke W.
    Moore, John
    Ladak, Hanif
    Moehring, Amanda
    Baron, Corey A.
    Khan, Ali R.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (05) : 2482 - 2496
  • [2] 3D Printed Scaffolds for Monolithic Aerogel Photocatalysts with Complex Geometries
    Schreck, Murielle
    Kleger, Nicole
    Matter, Fabian
    Kwon, Junggou
    Tervoort, Elena
    Masania, Kunal
    Studart, Andre R.
    Niederberger, Markus
    SMALL, 2021, 17 (50)
  • [3] Challenges in hemodynamics assessment in complex neurovascular geometries using computational fluid dynamics and benchtop flow simulation in 3D printed patient specific phantoms
    Paccione, Eric
    Ionita, Ciprian N.
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [4] 3D printed realistic finger vein phantoms
    Spreeuwers, Luuk
    van der Grift, Rasmus
    Normakristagaluh, Pesigrihastamadya
    12TH INTERNATIONAL WORKSHOP ON BIOMETRICS AND FORENSICS, IWBF 2024, 2024,
  • [5] An individual approach to Molecular radiotherapy dosimetry using 3D printed phantoms
    Pietras, B.
    Cullen, D.
    Price, E.
    Pells, S.
    Calvert, N.
    Hamilton, D.
    Page, E.
    Tipping, J.
    Robinson, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S731 - S731
  • [6] Buildability of complex 3D-printed concrete geometries using Peridynamics
    Zhu, Jinggao
    Cervera, Miguel
    Ren, Xiaodan
    AUTOMATION IN CONSTRUCTION, 2024, 165
  • [7] Accessing 3D Printed Vascular Phantoms for Procedural Simulation
    Coles-Black, Jasamine
    Bolton, Damien
    Chuen, Jason
    FRONTIERS IN SURGERY, 2021, 7
  • [8] Commercial filament testing for use in 3D printed phantoms
    Savi, Matheus
    Andrade, Marco A. B.
    Potiens, Maria P. A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 174
  • [9] Characterization and Application of 3D Printed Phantoms for Biophotonic Imaging
    Wang, Jianting
    Coburn, James
    Liang, Chia-Pin
    Woolsey, Nicholas
    Le, Du
    Ramella-Roman, Jessica
    Chen, Yu
    Pfefer, Joshua
    SMART BIOMEDICAL AND PHYSIOLOGICAL SENSOR TECHNOLOGY X, 2013, 8719
  • [10] Evaluation of challenges and limitations of mechanical thrombectomy using 3D printed neurovascular phantoms
    Sommer, Kelsey N.
    Bhurwani, Mohammad Mahdi Shiraz
    Mokin, Maxim
    Ionita, Ciprian N.
    MEDICAL IMAGING 2021: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2021, 11601