Transient Modeling of Refrigerant-to-Air Fin-and-Tube Heat Exchangers

被引:17
|
作者
Ndiaye, Demba [1 ]
Bernier, Michel [2 ]
机构
[1] Univ Moncton, Dept Genie Mecan, Moncton, NB E1A 3E9, Canada
[2] Ecole Polytech, Dept Genie Mecan, Montreal, PQ H3C 3A7, Canada
来源
HVAC&R RESEARCH | 2010年 / 16卷 / 03期
关键词
PERFORMANCE; WATER; PURE;
D O I
10.1080/10789669.2010.10390909
中图分类号
O414.1 [热力学];
学科分类号
摘要
A detailed transient model of a refrigerant-to-air fin-and-tube heat exchanger operating either in heating or cooling (including dehumidification) mode is presented. An indexation technique is proposed to account for the complex circuitry of the tubing often found in these types of heat exchangers. In addition, the model addresses the ON/OFF operation of the compressor and of the fan (at compressor shut-down, the fan may be ON or OFF). The partial derivatives equations resulting from the application of the mass, momentum, or energy conservation equations to the single-phase and two-phase flow of the refrigerant in the tubes and to the flow of the air over the tubes walls and fins are solved numerically using the finite volume method. The model is experimentally validated in steady-state and transient conditions. The results of this validation show a good agreement between the experiments and the model.
引用
收藏
页码:355 / 381
页数:27
相关论文
共 50 条
  • [31] Numerical study on performance and fin efficiency of wavy fin-and-tube heat exchangers
    Tao, Yubing
    He, Yaling
    Qu, Zhiguo
    Tao, Wenquan
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2011, 11 (3-4): : 246 - 254
  • [32] A comparative study of compact enhanced fin-and-tube heat exchangers
    Wang, CC
    Lee, WS
    Sheu, WJ
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (18) : 3565 - 3573
  • [33] Investigation of wavy fin-and-tube heat exchangers: A contribution to databank
    Wang, CC
    Lin, YT
    Lee, CJ
    Chang, YJ
    EXPERIMENTAL HEAT TRANSFER, 1999, 12 (01) : 73 - 89
  • [34] An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners
    Ahn, YC
    Cho, JM
    Shin, HS
    Hwang, YJ
    Lee, CG
    Lee, JK
    Lee, HU
    Kang, TW
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 20 (05) : 873 - 877
  • [35] Air-side heat transfer and friction correlations for plain fin-and-tube heat exchangers with staggered tube arrangements
    Kim, N.H.
    Youn, B.
    Webb, R.L.
    Journal of Heat Transfer, 1999, 121 (03): : 662 - 667
  • [36] Effect of corrosion on performance of fin-and-tube heat exchangers with different fin materials
    Zhao, Yu
    Qi, Zhaogang
    Wang, Qinren
    Chen, Jiangping
    Shen, Jun
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 37 : 98 - 103
  • [37] Experimental and numerical investigation on air-side performance of fin-and-tube heat exchangers with various fin patterns
    Tang, L. H.
    Zeng, M.
    Wang, Q. W.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (05) : 818 - 827
  • [38] An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners
    Young-Chull Ahn
    Jae-Min Cho
    Hee-Soo Shin
    Yu-Jin Hwang
    Chang-Gun Lee
    Jae-Keun Lee
    Hyun-Uk Lee
    Tae-Wook Kang
    Korean Journal of Chemical Engineering, 2003, 20 : 873 - 877
  • [39] An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners
    Ahn, Young Chull
    Kim, Gil Tae
    Hwang, Yu Jin
    Cheong, Seong Ir
    Lee, Jae-Keun
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 139 - +
  • [40] Transient behavior simulation of fin-and-tube heat exchangers for the variation of the inlet temperatures of both fluids
    Vaisi, A.
    Talebi, S.
    Esmaeilpour, M.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2011, 38 (07) : 951 - 957