The determination of glutamine with flow-injection chemiluminescence detection and mechanism study

被引:7
|
作者
Liu, Yan-Ming [1 ]
Liu, Zhuan-Li [1 ]
Shi, Yan-Mei [1 ]
Tian, Wei [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
基金
中国国家自然科学基金;
关键词
glutamine; chemiluminescence; flow-injection; mechanism study; AMINO-ACIDS; CAPILLARY-ELECTROPHORESIS; LUMINOL; NUTRITION; FLUIDS; MEDIA; ASSAY;
D O I
10.1002/bio.1143
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The main purpose of this study was to develop an inexpensive, simple, rapid and sensitive chemiluminescence (CL) method for the determination of glutamine (Gln) using a flow-injection (FI) system. Gin was found to strongly inhibit the CL signal of the luminol-H2O2-CuSO4 system in Na2B4O7 solution. A new FI-CL method was developed for the determination of Gin. Parameters affecting the reproducibility and CL detection were optimized systematically. Under the optimized conditions, the corresponding linear regression equation was established over the range of 5.0 x 10(-7) to 2.5 x 10(-6) mol/L with the detection limit of 1.8 x 10(-8) mol/L. The relative standard deviation was found to be 1.8% for 11 replicate determinations of 1.5 x 10(-6) mol/L Gln. The proposed method has been satisfactorily applied for the determination of Gln in real samples (Marzulene-s granules) with recoveries in the range of 98.7-108.6%. The minimum sampling rate was about 100 samples/h. The possible mechanism of this inhibitory CL was studied by fluorescence spectrophotometer and UV-vis spectrophotometer. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 50 条
  • [41] Flow-injection chemiluminescence determination of chlorinated isocyanuric acids
    Safavi, A
    Karimi, MA
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (05) : 424 - 427
  • [42] DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
    唐玉海
    韩小年
    于春玲
    孙媛媛
    姚宏
    Academic Journal of Xi'an Jiaotong University, 2006, (02) : 136 - 138
  • [43] A novel flow-injection chemiluminescence system for the determination of guanine
    Yang, M
    Liu, R
    Hou, DY
    Guo, YY
    LUMINESCENCE, 2005, 20 (4-5) : 307 - 310
  • [44] Determination of ofloxacin using a chemiluminescence flow-injection method
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, G
    Baeyens, WRG
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 227 - 230
  • [45] Determination of Three Imidazole Derivatives by Flow-Injection Chemiluminescence
    Sun, Sijuan
    Tang, Yuhai
    Fu, Qiang
    Chen, Jine
    Zhang, Guangbin
    ANALYTICAL LETTERS, 2009, 42 (12) : 1868 - 1881
  • [46] FLOW-INJECTION DETERMINATION OF ETHANOL BY FIBEROPTIC CHEMILUMINESCENCE MEASUREMENT
    XIE, XF
    SULEIMAN, AA
    GUILBAULT, GG
    YANG, ZM
    SUN, ZA
    ANALYTICA CHIMICA ACTA, 1992, 266 (02) : 325 - 329
  • [47] Chemiluminescence determination of ultramicro DNA with a flow-injection method
    Chen, H
    Zhou, M
    Jin, XY
    Song, YM
    Zhang, ZY
    Ma, YJ
    ANALYTICA CHIMICA ACTA, 2003, 478 (01) : 31 - 36
  • [48] CHEMILUMINESCENCE DETERMINATION OF BUPRENORPHINE HYDROCHLORIDE BY FLOW-INJECTION ANALYSIS
    ALWARTHAN, AA
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1986, 185 : 329 - 333
  • [49] Flow-injection chemiluminescence determination of chlorinated isocyanuric acids
    Afsaneh Safavi
    Mohammad Ali Karimi
    Analytical and Bioanalytical Chemistry, 2003, 375 : 424 - 427
  • [50] Flow-injection post chemiluminescence determination of atropine sulfate
    Sun, Shuwen
    Lu, Jiuru
    ANALYTICA CHIMICA ACTA, 2006, 580 (01) : 9 - 13