Long-term monitoring of intracranial pressure in normal pressure hydrocephalus and other CSF disorders

被引:28
|
作者
Czosnyka, Zofia [1 ]
Czosnyka, Marek [1 ]
机构
[1] Cambridge Univ Hosp, Dept Clin Neurosci, Div Neurosurg, Brain Phys Lab, Cambridge, England
关键词
Intracranial pressure; Pressure waves; Normal pressure hydrocephalus; Idiopathic intracranial hypertension; CONDUCTANCE; OUTFLOW;
D O I
10.1007/s00701-017-3282-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Long-term monitoring of intracranial pressure is a useful method in the diagnosis of complex hydrocephalus and CSF disorders. This editorial discusses various criteria for the interpretation of ICP monitoring in normal pressure hydrocephalus, idiopathic intracranial hypertension and in patients with implanted hydrocephalus shunts.
引用
收藏
页码:1979 / 1980
页数:2
相关论文
共 50 条
  • [41] LONG-TERM RECORDING OF INTRACRANIAL-PRESSURE
    WATSON, BW
    CURRIE, JCM
    RIDDLE, HC
    MELDRUM, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (01): : 86 - 95
  • [42] CONTINUOUS INTRACRANIAL PRESSURE MONITORING IN COMMUNICATING HYDROCEPHALUS
    DORSCH, NWC
    SYMON, L
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1972, 35 (06): : 922 - 923
  • [43] Shunt therapy in idiopathic normal pressure hydrocephalus: results from a long-term observation
    Grasso, G.
    Torregrossa, F.
    FLUIDS AND BARRIERS OF THE CNS, 2022, 19
  • [44] Diagnosis, treatment, and analysis of long-term outcomes in idiopathic normal-pressure hydrocephalus
    McGirt, MJ
    Woodworth, G
    Coon, AL
    Thomas, G
    Williams, MA
    Rigamonti, D
    NEUROSURGERY, 2005, 57 (04) : 699 - 705
  • [45] Long-term telemetric intracranial pressure monitoring for diagnosis and therapy optimisation of idiopathic intracranial hypertension
    Velazquez Sanchez, Victor F.
    Al Dayri, Giath
    Tschan, Christoph A.
    BMC NEUROLOGY, 2021, 21 (01)
  • [46] Long-term telemetric intracranial pressure monitoring for diagnosis and therapy optimisation of idiopathic intracranial hypertension
    Victor F. Velazquez Sanchez
    Giath Al Dayri
    Christoph A. Tschan
    BMC Neurology, 21
  • [47] Wirelessly Powered Implantable System for Wireless Long-Term Monitoring of Intracranial Pressure
    Khan, M. Waqas A.
    Sydanheimo, Lauri
    Bjorninen, Toni
    Ukkonen, Leena
    2017 INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY: SMALL ANTENNAS, INNOVATIVE STRUCTURES, AND APPLICATIONS (IWAT), 2017, : 122 - 124
  • [48] LONG-TERM PERFORMANCE OF A CE-APPROVED TELEMETRIC INTRACRANIAL PRESSURE MONITORING
    Kiefer, Michael
    Antes, Sebastian
    Schmitt, Melanie
    Krause, Inga
    Eymann, Regina
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2246 - 2249
  • [49] Modification of subdural catheters for long-term intracranial pressure monitoring of conscious rabbits
    Storrow, AB
    Hoxie, N
    CONTEMPORARY TOPICS IN LABORATORY ANIMAL SCIENCE, 1998, 37 (03): : 62 - 65
  • [50] CSF PRESSURE MONITORING AND CONTROLLED CSF DRAINAGE VIA LUMBAR SUBARACHNOID CATHETER IN PATIENTS WITH SUSPECTED NORMAL-PRESSURE HYDROCEPHALUS
    WILLIAMS, MA
    RAZUMOVSKY, AY
    SELNES, O
    HERDMAN, S
    HANLEY, DF
    ANNALS OF NEUROLOGY, 1993, 34 (02) : 257 - 257