Roles of Transit-Time Flow Measurement for Coronary Artery Bypass Surgery

被引:15
|
作者
Takami, Yoshiyuki [1 ]
Takagi, Yasushi [1 ]
机构
[1] Fujita Hlth Univ, Sch Med, Dept Cardiovasc Surg, 1-98 Dengakugakubo Kutsukake Cho, Toyoake, Aichi 4701192, Japan
来源
THORACIC AND CARDIOVASCULAR SURGEON | 2018年 / 66卷 / 06期
关键词
coronary artery bypass grafting; transit-time flow measurement; graft flow; coronary circulation; OFF-PUMP; BLOOD-FLOW; GRAFT FLOW; ON-PUMP; COMPLETE REVASCULARIZATION; EPICARDIAL ULTRASOUND; IN-VIVO; FAILURE; FLOWMETRY; PATENCY;
D O I
10.1055/s-0037-1618575
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transit-time flow measurement (TTFM) has been increasingly applied to detect graft failure during coronary artery bypass grafting (CABG), because TTFM is less invasive, more reproducible, and less time consuming. Many authors have attempted to validate TTFM and to gain the clear cutoff values and algorithm in TTFM to predict graft failure. The TTFM technology has also been shown to be a useful tool to investigate CABG graft flow characteristics and coronary circulation physiology. It is important to recognize the practical roles of TTFM in the cardiac operating room by review and summarize the literatures.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
  • [31] Transit time flow measurement and outcome in coronary artery bypass grafting for surgeon and trainee
    Pheng Hian Tan
    Azmi, Muhammad Ibrahim
    Zulkifli, Zhafri
    Amin, Mohd Afiq
    Hassan, Syed Nasir Syed
    Zulkifli, Mohd Faizal Effendi
    Hashim, Shahrul Amry
    JOURNAL OF THORACIC DISEASE, 2022, 14 (01) : 36 - 42
  • [32] Does Coronary Endarterectomy Affect the Transit Time Flow Measurement in Coronary Artery Bypass Grafting? REPLY
    Lehnert, Per
    Moller, Christian H.
    JOURNAL OF CARDIAC SURGERY, 2015, 30 (12) : 896 - 897
  • [33] Comparison of intraoperative transit-time flow measurement with early postoperative magnetic resonance flow mapping - in off-pump coronary artery surgery
    Sanisoglu, I
    Guden, M
    Balci, C
    Sagbas, E
    Duran, C
    Akpinar, B
    TEXAS HEART INSTITUTE JOURNAL, 2003, 30 (01) : 31 - 37
  • [34] Intraoperative evaluation of coronary anastomosis by transit-time ultrasonic flow measurement
    Morota, T
    Duhaylongsod, FG
    Burfeind, WR
    Huang, CT
    ANNALS OF THORACIC SURGERY, 2002, 73 (05): : 1446 - 1450
  • [35] PREDICTORS OF HIGH AND LOW GRAFT FLOW FOR ISOLATED CORONARY ARTERY BYPASS GRAFTS USING TRANSIT-TIME FLOWMETRY
    Forcillo, J.
    Noiseux, N.
    Dubois, M. J.
    Mansour, S.
    Prieto, I.
    Basile, F.
    Stevens, L. M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S255 - S255
  • [36] Intraoperative assessment of coronary artery bypass graft: Transit-time flowmetry versus angiography
    Shin, H
    Yozu, R
    Mitsumaru, A
    Iino, Y
    Hashizume, K
    Matayoshi, T
    Kawada, S
    ANNALS OF THORACIC SURGERY, 2001, 72 (05): : 1562 - 1565
  • [37] Predicting midterm coronary artery bypass graft failure by intraoperative transit time flow measurement
    Tokuda, Yoshiyuki
    Song, Min-Ho
    Oshima, Hideki
    Usui, Akihiko
    Ueda, Yuichi
    ANNALS OF THORACIC SURGERY, 2008, 86 (02): : 532 - 536
  • [38] Transit time flow measurement in coronary artery bypass grafting: For every patient and every surgeon
    Sandner, Sigrid
    Salerno, Tomas
    Gaudino, Mario F. L.
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (12) : 4456 - 4459
  • [39] Clinical value of intra-operative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study
    Jokinen, Janne J.
    Werkkala, Kalervo
    Vainikka, Tiina
    Perakyla, Tarja
    Simpanen, Jarmo
    Ihlberg, Leo
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 918 - 923
  • [40] Predicting early coronary artery bypass graft failure by intraoperative transit time flow measurement
    Tokuda, Yoshiyuki
    Song, Min-Ho
    Ueda, Yuichi
    Usui, Akihiko
    Akita, Toshiaki
    ANNALS OF THORACIC SURGERY, 2007, 84 (06): : 1928 - 1934