A Monte Carlo dosimetry study using Henschke applicator for cervical brachytherapy

被引:12
|
作者
Yu, Pei-Chieh [2 ,4 ]
Chao, Tsi-Chian [1 ]
Lee, Chung-Chi [1 ,3 ]
Wu, Ching-Jung [4 ]
Tung, Chuan-Jong [1 ]
机构
[1] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Tao Yuan 333, Taiwan
[2] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 30013, Taiwan
[3] Chang Gang Mem Hosp, Dept Radiat Oncol, Tao Yuan 333, Taiwan
[4] Cathay Gen Hosp, Dept Radiat Oncol, Taipei 106, Taiwan
关键词
Brachytherapy; Henschke applicator; MCNP; Mesh tally;
D O I
10.1016/j.nima.2010.01.079
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In recent years the Henschke applicator has been widely used for gynecologic patients treated by brachytherapy in Taiwan. However, the commercial brachytherapy planning system did not properly evaluate the dose perturbation caused by the Henschke applicator. Since the European Society for Therapeutic Radiology and Oncology advised that the effect of source shielding should be incorporated into the brachytherapy planning system, it required calculation and comparison of the dose distribution around the applicator. This study used the Monte Carlo MCNP code to simulate the dose distribution in a water phantom that contained the Henschke applicator with one tandem and two ovoids. Three dwell positions of a high dose rate Ir-192 source were simulated by including and excluding the applicator. The mesh tally option of the MCNP was applied to facilitate the calculation of a large number of tallies in the phantom. The voxel size effect and the charge particle equilibrium were studied by comparing the results calculated with different tally options. The calculated results showed that the brachytherapy planning system overestimated the rectal dose and that the shielding material in the applicator contributed more than 40% to the rectal dose. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:411 / 414
页数:4
相关论文
共 50 条
  • [41] MONTE CARLO DOSIMETRY OF HIGH DOSE RATE GYNECOLOGIC INTERSTITIAL BRACHYTHERAPY
    Desbiens, M.
    D'Amours, M.
    Afsharpour, H.
    Thibault, I.
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S59 - S59
  • [42] Monte Carlo dosimetry for a new 32P brachytherapy source using FLUKA code
    Rajabi, Razieh
    Taherparvar, Payvand
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (01) : 76 - 90
  • [43] DVH-Based Inverse Planning Using Monte Carlo Dosimetry for LDR Prostate Brachytherapy
    Mountris, Konstantinos A.
    Visvikis, Dimitris
    Bert, Julien
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 103 (02): : 503 - 510
  • [44] Derivation of dosimetry data for brachytherapy sources using Monte Carlo for primary and scatter dose separation
    Russell, KR
    Ahnesjö, A
    Carlsson, ÅK
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 495 - 497
  • [45] Monte Carlo model for a prototype CT-compatible, anatomically adaptive, shielded intracavitary brachytherapy applicator for the treatment of cervical cancer
    Price, Michael J.
    Gifford, Kent A.
    Horton, John L., Jr.
    Eifel, Patricia J.
    Gillin, Michael T.
    Lawyer, Ann A.
    Mourtada, Firas
    MEDICAL PHYSICS, 2009, 36 (09) : 4147 - 4155
  • [46] Dosimetric analysis of a shielded applicator for nasopharyngeal carcinoma intracavitary brachytherapy: Monte Carlo calculation
    Chen, LX
    Liu, XW
    You, RA
    Qian, JY
    Qi, ZY
    Deng, XW
    Tsao, SY
    MEDICAL PHYSICS, 2006, 33 (03) : 761 - 769
  • [47] Monte Carlo simulation of a Fletcher-Suit-Delclos applicator for LDR brachytherapy (WIP)
    Rodriguez-Villafuert, M
    Martinez-Davalos, A
    MEDICAL PHYSICS, 2003, 30 (06) : 1469 - 1469
  • [48] Comprehensive Dosimetric Characterization of the Novel Direction Modulation Brachytherapy (DMBT) Tandem Applicator Using Monte Carlo Simulations
    Safigholi, H.
    Han, D.
    Mashouf, S.
    Soliman, Abraam
    Owrangi, A.
    Song, W. Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3468 - 3468
  • [49] Dosimetry of Strontium eye applicator: Comparison of Monte Carlo calculations and radiochromic film measurements
    Laoues, M.
    Khelifi, R.
    Moussa, A. S.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [50] Dose modification factor analysis of multilumen balloon brachytherapy applicator with Monte Carlo simulation
    Pearson, David
    Williams, Eric A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 54 - 62